https://www.phoenixcontact.com/us/products/1569508
Bus system cable - SAC-4P-M12MSD/ 0,3-931/M12FSD - 1569508
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
Bus system cable, Ethernet CAT5 (100 Mbps), Ethernet CAT5e (100 Mbps), Ethernet, 4-position, PUR halogenfree, water blue RAL 5021, shielded, Plug straight M12, D-coded, on Socket straight M12, D-coded, Cable length:
0.3 m
Key commercial data
Packing unit
11
Custom tariff number
85444290
Country of origin
Germany
Technical data
Dimensions
Length of cable
0.3 m
Ambient conditions
Ambient temperature (operation)
-25 °C ... 90 °C (Plug / socket)
Degree of protection
IP65
IP67
General
Rated current at 40°C
4A
Rated voltage
60 V
Number of positions
4
Contact resistance
≤ 5 mΩ
Insulation resistance
≥ 100 MΩ
Coding
D - data
Signal type/category
Ethernet CAT5, 100 Mbps
Ethernet CAT5e, 100 Mbps
Status display
No
Surge voltage category
II
11.11.2013 Page 1 / 4
https://www.phoenixcontact.com/us/products/1569508
Bus system cable - SAC-4P-M12MSD/ 0,3-931/M12FSD - 1569508
Technical data
General
Pollution degree
3
Insertion/withdrawal cycles
≥ 100
Material
Inflammability class according to UL 94
V0
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA 66
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR
Cable
Cable type
PUR ETHERNET 2x2 FLEX
Cable type (abbreviation)
93E
UL AWM style
20963 (80°C/30 V)
Cable structure
2x2xAWG26/7; SF/UTP
Conductor cross section
2x 2x 0.14 mm²
AWG signal line
26
Conductor structure signal line
7x 0.16 mm
Core diameter including insulation
0.98 mm
Wire colors
white/orange-orange, white/green-green
Twisted pairs
2 cores to the pair
Overall twist
Two pairs with two fillers to the core
Shielding
Aluminum-coated foil, tinned copper braided shield
Optical shield covering
70 %
External sheath, color
water blue RAL 5021
External cable diameter D
6.4 mm ± 0.2 mm
Minimum bending radius, fixed installation
4xD
Minimum bending radius, flexible installation
8xD
Cable weight
42 kg/km
Outer sheath, material
PUR
Material conductor insulation
Foamed PE
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 500 MΩ*km (at 20 °C)
Conductor resistance
≤ 290 Ω/km (at 20 °C)
Transmission characteristics (category)
CAT5 (IEC 11801:2002), CAT5e (TIA 568B:2001)
Working capacitance
45 nF (At 1 kHz)
11.11.2013 Page 2 / 4
https://www.phoenixcontact.com/us/products/1569508
Bus system cable - SAC-4P-M12MSD/ 0,3-931/M12FSD - 1569508
Technical data
Cable
Wave impedance
100 Ω ± 5 Ω (At 100 MHz)
Signal runtime
5.3 ns/m
Nominal voltage, cable
≤ 100 V
300 V (Outer cable sheath)
Test voltage Core/Core
700 V (50 Hz, 1 min.)
Test voltage Core/Shield
700 V (50 Hz, 1 min.)
Flame resistance
IEC 60332-1-2
Halogen-free
According to IEC 60754-1
Resistance to oil
in accordance with DIN EN 60811-2-1
Ambient temperature (operation)
-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
Classifications
eCl@ss
eCl@ss 4.0
27060306
eCl@ss 4.1
27060306
eCl@ss 5.0
27061801
eCl@ss 5.1
27061801
eCl@ss 6.0
27061801
eCl@ss 7.0
27061801
eCl@ss 8.0
27061801
ETIM
ETIM 3.0
EC001855
ETIM 4.0
EC001855
ETIM 5.0
EC001855
UNSPSC
UNSPSC 6.01
31251501
UNSPSC 7.0901
31251501
UNSPSC 11
31251501
UNSPSC 12.01
31251501
UNSPSC 13.2
31251501
Drawings
11.11.2013 Page 3 / 4
https://www.phoenixcontact.com/us/products/1569508
Bus system cable - SAC-4P-M12MSD/ 0,3-931/M12FSD - 1569508
Schematic diagram
Schematic diagram
4
3
3
4
1
2
2
1
Pin assignment M12 male connector, 4-pos., D-coded, male side
Pin assignment M12 socket, 4-pos., D-coded, female side
Cable cross section
Dimensioned drawing
Ø12
M12
Ø14,8
47,3
Ethernet [93E]
Plug, M12 x 1, straight, shielded
Dimensioned drawing
Circuit diagram
M12
Ø15
Ø12
M12
44,5
M12
1
1
3
3
2
2
4
4
M12 x 1 socket, straight, shielded
© Phoenix Contact 2013 - all rights reserved
http://www.phoenixcontact.com
11.11.2013 Page 4 / 4