Contact insert module - HC-M-02-HS-70/16-MOD-BU - 1585715
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
HEAVYCON contact insert module, socket, 2-pos. to 70 A, 16 mm² axial screw connection
Key Commercial Data
Packing unit
1 pc
Minimum order quantity
2 pc
Weight per Piece (excluding packing)
32.12 g
Custom tariff number
85366990
Country of origin
Germany
Technical data
Electrical characteristics
Note
For HEAVYCON HC-B6 to B48 housing, HC-M-MHR... hinged retaining
frame required, axial connection for 2.5 mm Allen key
Rated voltage (III/3)
1000 V
Rated current
70 A
Rated surge voltage
8 kV
Number of positions
2
Ambient conditions
Ambient temperature (operation)
-40 °C ... 125 °C
Mechanical characteristics
Conductor cross section
6 mm² ... 16 mm²
Connection cross section AWG
8 ... 6
Stripping length of the individual wire
11 mm +1
Tightening torque
2 Nm (6 mm²)
3 Nm (10 mm²)
03/28/2016 Page 1 / 4
https://www.phoenixcontact.com/us/products/1585715
Contact insert module - HC-M-02-HS-70/16-MOD-BU - 1585715
Technical data
Mechanical characteristics
4 Nm (16 mm²)
Wire diameter including insulation
8.9 mm
Hexagonal socket
SW2,5
Insertion/withdrawal cycles
≥ 500
Minimum housing height
72 mm
General
Series
HC-M-HS
Number of module slots
1
Connection method
Axial screw connection
Flammability rating according to UL 94
V0
Degree of pollution
3
Overvoltage category
III
Assembly instructions
Use 2.5 mm Allen wrenches for axial connection. Only for stranded wires.
For housing heights h ≥ 52 mm. Plug-in connections may only be operated
only when there is no load/voltage.
Connection
Note regarding axial connection technology:
Only for stranded wires. The specified conductor cross sections refer to
the geometric cross section of the cable used.
Cables with a geometric cross section which deviates significantly from
the nominal cable cross section must be checked before use.
The axial connection technology connection space is designed for fine
strand cables according to VDE 0295 Class 5. Deviating cable structures
(e.g., Class 6 cables) must be checked before use.
Assembly instructions
Before assembly, ensure that the tapered screw is fully loosened
(chamber is open). Cables must not be twisted. The wires must be pushed
into the contact chamber as far as they will go (until the insulation touches
the contact). Hold the wires in position and tighten using an Allen key. The
used wire end must be cut off before reconnection. The terminal screw
must only be retightened once to prevent the litz wires from breaking.
To prevent damage to the contact, the wire/cable must be mechanically
held at an appropriate distance from the connection point (e.g., when
used in a plate cut out). For notes on correct execution, see DIN VDE
0100-520:2003-06. Unused connections must be tightened with maximum
torque.
Material data
Contact material
Copper alloy
Contact surface material
Ag
Contact carrier material
PC
Standards and Regulations
Connection in acc. with standard
UL
Flammability rating according to UL 94
V0
03/28/2016 Page 2 / 4
https://www.phoenixcontact.com/us/products/1585715
Contact insert module - HC-M-02-HS-70/16-MOD-BU - 1585715
Classifications
eCl@ss
eCl@ss 4.0
272607xx
eCl@ss 4.1
27260701
eCl@ss 5.0
27143424
eCl@ss 5.1
27143424
eCl@ss 6.0
27143424
eCl@ss 7.0
27440209
eCl@ss 8.0
27440207
ETIM
ETIM 3.0
EC000438
ETIM 4.0
EC000438
ETIM 5.0
EC000438
UNSPSC
UNSPSC 6.01
43172601
UNSPSC 7.0901
39121416
UNSPSC 11
43172601
UNSPSC 12.01
39121408
UNSPSC 13.2
39121408
Approvals
Approvals
Approvals
UL Recognized / EAC / EAC
Ex Approvals
Approvals submitted
Approval details
03/28/2016 Page 3 / 4
https://www.phoenixcontact.com/us/products/1585715
Contact insert module - HC-M-02-HS-70/16-MOD-BU - 1585715
Approvals
UL Recognized
mm²/AWG/kcmil
4
Nominal current IN
70 A
Nominal voltage UN
600 V
EAC
EAC
Drawings
Diagram
Operating current [A]
Schematic diagram
1
2
100
1
80
60
40
1 = 16 mm
20
2 = 6 mm
2
2
2
0
0
20
40
60
80
100
120
Ambient temperature [°C]
Connector pin assignment, connection side
Derating diagram (6 modules in HC-B 24 housing)
Dimensional drawing
14,6
Schematic diagram
46,5
34,2
1
Axial screw connection
2
Socket module
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
03/28/2016 Page 4 / 4