Contact insert - HC-HS 2-D7-EBUS - 1586264
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
HEAVYCON female insert, HS2 series, 2+PE-pos., axial screw connection
Key commercial data
Packing unit
1 PCE
Minimum order quantity
10 PCE
GTIN
Custom tariff number
85366990
Country of origin
GERMANY
Technical data
General data
Note
For housing HC-D7
Connection method
Axial screw connection
Tightening torque
1.8 Nm
Ambient temperature (operation)
-40 °C ... 125 °C (including heating up of contacts)
Pollution degree
3
Surge voltage category
III
Constructional and testing regulations
DIN VDE 0627/86
Constructional and testing regulations
DIN VDE 0110/02.79
Constructional and testing regulations
DIN VDE 0110-1/04.97
Constructional and testing regulations
IEC 60664-1, DIN IEC 60512
Constructional and testing regulations
IEC 60352
Number of positions
2+PE
Insertion/withdrawal cycles
≥ 500
19.04.2013 Page 1 / 5
https://www.phoenixcontact.com/us/produkte/1586264
Contact insert - HC-HS 2-D7-EBUS - 1586264
Technical data
General data
Design
D7
Conductor cross section
4 mm² ... 10 mm²
Connection cross section AWG
10 ... 8
Stripping length of the individual wire
8 mm +1
Assembly instructions
-The axial screw connection must be established using a 2 mm Allen
wrench.
-Use only stranded wires for axial screw connection.
-Plug-in connections may only be operated only when there is no load/
voltage.
Connection
Note regarding axial connection technology:
Only for stranded wires. The specified conductor cross sections refer to
the geometric cross section of the cable used.
Use of cables with a geometric cross section very different from the
cable's nominal cross section should be checked before use.
The wiring space of the axial screw method is established for fine strand
cables in accordance with VDE 0295 Class 5. Deviating cable structures
(e.g., Class 6 cables) should be checked before use.
Assembly instructions
Before assembly, ensure that the tapered screw is turned back all the way
(chamber is open). The cables must not be twisted.
The wires should be inserted as far as they will go into the contact
chamber (until the insulation touches the contact). Hold the wires in
position and use the socket wrench to tighten. The used wire end should
be cut off before connecting again. The connection screw may only be
retightened once to prevent the litz wires from breaking. To prevent
damage to the contact, the wire/cable should be mechanically intercepted
at an appropriate distance from the connection point (e.g., by using a plate
cutout). DIN VDE 0100-520:2003-06 contains information on how to do
this correctly. When not using PE contacts: set the PE contact as far as
possible in a clockwise direction.
Material data
Inflammability class according to UL 94
V0
Contact material
Copper alloy
Contact surface material
Ag
Contact carrier material
PC
Electrical characteristics
Rated voltage (III/3)
400 V
Rated surge voltage
6 kV
Rated current
40 A
Classifications
ETIM
ETIM 3.0
EC000438
19.04.2013 Page 2 / 5
https://www.phoenixcontact.com/us/produkte/1586264
Contact insert - HC-HS 2-D7-EBUS - 1586264
Classifications
ETIM
ETIM 4.0
EC000438
ETIM 5.0
EC000438
UNSPSC
UNSPSC 11
39121522
UNSPSC 12.01
39121522
UNSPSC 13.2
39121522
UNSPSC 6.01
30211923
UNSPSC 7.0901
39121522
eCl@ss
eCl@ss 4.0
272607xx
eCl@ss 4.1
27260701
eCl@ss 5.0
27143424
eCl@ss 5.1
27143424
eCl@ss 6.0
27143424
eCl@ss 7.0
27440209
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / GOST / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
UL Recognized
Nominal current IN
28 A
19.04.2013 Page 3 / 5
https://www.phoenixcontact.com/us/produkte/1586264
Contact insert - HC-HS 2-D7-EBUS - 1586264
Approvals
Nominal voltage UN
600 V
cUL Recognized
Nominal current IN
28 A
Nominal voltage UN
600 V
GOST
cULus Recognized
Drawings
1
2
Diagram
Operating current [A]
Schematic diagram
100
80
2
60
40
1
20 1 = 6 mm2
2 = 10 mm²
0
20
40
60
80
100
120
Ambient temperature [°C]
Derating diagram: Series HC-HS2-D7-E...S
19.04.2013 Page 4 / 5
https://www.phoenixcontact.com/us/produkte/1586264
Contact insert - HC-HS 2-D7-EBUS - 1586264
Dimensioned drawing
34,8
21
21
Schematic diagram
Axial connection
Female insert
© Phoenix Contact 2013 - all rights reserved
http://www.phoenixcontact.com
19.04.2013 Page 5 / 5