HC-M-HS-MOD-ST
Order No.: 1605000
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1605000
HEAVYCON contact insert module, male, 2-pos. to 100 A, screw
connection
Product notes
WEEE/RoHS-compliant since:
07/11/2006
Commercial data
GTIN (EAN)
4
017918
893293
sales group
D042
Pack
1 pcs.
Customs tariff
85369010
Catalog page information
Page 452 (PC-2009)
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Electrical characteristics
Note
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Required for housing HC-B6 to B48, (housing height min. 72
mm), housing HC-ADVANCE-B6 to B24, hinged retaining frame
HC-M-MHR..., axial connection for 4 mm Allen wrench
Page 1 / 5
Jan 27, 2011
HC-M-HS-MOD-ST Order No.: 1605000
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1605000
Rated voltage (III/3)
1000 V
Rated current
100 A
Rated surge voltage
8 kV
Ambient temperature (operation)
-40 °C ... 125 °C
Number of positions
2
Mechanical characteristics
Conductor cross-section
16 mm² ... 35 mm²
Connection cross-section AWG
4 ... 2
Stripping length of the individual wire
13 mm
Tightening torque
6 Nm (16 mm )
2
2
7 Nm (25 mm )
2
8 Nm (35 mm )
Wire diameter including insulation
11.4 mm
Hexagonal socket
SW 4
Insertion/withdrawal cycles
≥ 500
General characteristics
Number of module slots
2
Connection method
Axial screw connection
Inflammability class acc. to UL 94
V0
Pollution degree
3
Surge voltage category
III
Assembly instructions
- Use HC housing h >= 72 mm- Connection of wires using a 4
mm Allen wrench- Axial screw connection only for stranded wiresPlug-in connections may only be operated only when there is no
load/voltage
Connection
Note for axial connection method The specified conductor
cross-sections refer to the geometric cross-section of the used
conductor.The use of conductors with a geometric crosssection that deviates greatly from the nominal cross-section
of the conductor should be checked first.The wiring space of
the axial screw technology has been designed for fine strand
conductors as per VDE 0295 class 5. Deviating conductor
superstructures (e.g. class 6 conductors) must be checked before
use.Connection It must be ensured before installation that the
ball screw is completely turned back (chamber is open). Twisting
the conductors is not allowed. The cores must be pushed up to
the end of the contact chamber (until the contact is insulated).
Keep the core in this position and tighten it using an Allen key.
The required core end must be cut before a reconnection.
Tightening the connection screw is allowed only once in order to
prevent a breakage of the litz wire.
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 2 / 5
Jan 27, 2011
HC-M-HS-MOD-ST Order No.: 1605000
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1605000
Material data
Contact material
Copper alloy
Contact surface material
Ag
Contact carrier material
PC
Certificates / Approvals
Certification
CUL, GOST, UL
Accessories
Item
Designation
Description
HC-M-MHR-PE16
Cable lug for HEAVYCON-MODULAR; PE connection extension
2
to 16 mm , for crimping with crimp pliers
Plug/Adapter
1636981
Diagrams/Drawings
Diagram
Derating diagram (3 modules in HC-B 24 housing)
Dimensioned drawing
Male insert
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 3 / 5
Jan 27, 2011
HC-M-HS-MOD-ST Order No.: 1605000
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1605000
Schematic diagram
Axial connection
Connector pin assignment
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 4 / 5
Jan 27, 2011
HC-M-HS-MOD-ST Order No.: 1605000
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1605000
Address
PHOENIX CONTACT Deutschland GmbH
Flachsmarktstr. 8
32825 Blomberg,Germany
Phone +49 5235 3 12000
Fax +49 5235 3 41200
http://www.phoenixcontact.de
© 2010 Phoenix Contact
Technical modifications reserved;
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 5 / 5
Jan 27, 2011