Contact insert - VC-AML 5-PEA - 1607530
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Mounting contact insert with PCB connection, type: 3, Number of pos.: 4+PE
The figure shows the product version
VC-AML 5
Key Commercial Data
Packing unit
1 pc
Minimum order quantity
5 pc
GTIN
GTIN
4017918980399
Weight per Piece (excluding packing)
36.000 g
Custom tariff number
85366990
Country of origin
Poland
Technical data
Standards and Regulations
Connection in acc. with standard
CUL
Flammability rating according to UL 94
V0
Safety note
WARNING: The connectors may not be plugged in or disconnected under
load. Ignoring the warning or improper use may damage persons and/or
property.
• WARNING: Commission properly functioning products only. The products
must be regularly inspected for damage. Decommission defective products
immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate
the product. They must observe the following safety notes. The qualified
personnel must be familiar with the basics of electrical engineering. They
05/30/2020 Page 1 / 4
https://www.phoenixcontact.com/us/products/1607530
Contact insert - VC-AML 5-PEA - 1607530
Technical data
Standards and Regulations
must be able to recognize and prevent danger. The relevant symbol on the
packaging indicates that only personnel familiar with electrical engineering
are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and
electrical device engineering.
• When operating the connectors in outdoor applications, they must be
separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the
standards listed (e.g. the ones listed in the product accessories online at
phoenixcontact.com/products).
• When using the product in direct connection with third-party
manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must
be grounded
• Ensure that the protective or functional ground has been properly
connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are
applicable when combining several circuits in a cable and/or connector
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• The installation notes/Design In documents online on the download page
at phoenixcontact.com/products must be observed for this product.
• Use a protective cap to protect connectors that are not in use. The
suitable accessories are available online in the accessory section of the
product at phoenixcontact.com/products
• Operate the connector only when it is fully plugged in.
• Ensure that when laying the cable, the tensile load on the connectors
does not exceed the upper limit specified in the standards.
• Observe the minimum bending radius of the cable. Lay the cable without
twisting it.
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Classifications
eCl@ss
eCl@ss 10.0.1
27440205
05/30/2020 Page 2 / 4
https://www.phoenixcontact.com/us/products/1607530
Contact insert - VC-AML 5-PEA - 1607530
Classifications
eCl@ss
eCl@ss 4.0
27140800
eCl@ss 4.1
27140800
eCl@ss 5.0
27143400
eCl@ss 5.1
27261200
eCl@ss 6.0
27261200
eCl@ss 7.0
27440205
eCl@ss 8.0
27440205
eCl@ss 9.0
27440205
ETIM
ETIM 2.0
EC000438
ETIM 3.0
EC000438
ETIM 4.0
EC002637
ETIM 5.0
EC000438
ETIM 6.0
EC000438
ETIM 7.0
EC000438
UNSPSC
UNSPSC 6.01
30211923
UNSPSC 7.0901
39121522
UNSPSC 11
39121522
UNSPSC 12.01
39121522
UNSPSC 13.2
39121522
UNSPSC 18.0
39121522
UNSPSC 19.0
39121522
UNSPSC 20.0
39121522
UNSPSC 21.0
39121522
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / EAC / cULus Recognized
Ex Approvals
05/30/2020 Page 3 / 4
https://www.phoenixcontact.com/us/products/1607530
Contact insert - VC-AML 5-PEA - 1607530
Approvals
Approval details
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Nominal voltage UN
600 V
Nominal current IN
55 A
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Nominal voltage UN
600 V
Nominal current IN
45 A
FILE E 118976
FILE E 118976
EAC
B.01687
cULus Recognized
Accessories
Accessories
Coding element
Coding profile - CP-HCC 4 - 1600027
Coding profile, number of positions: 1, pitch: 0 mm, color: red
Phoenix Contact 2020 © - all rights reserved
http://www.phoenixcontact.com
05/30/2020 Page 4 / 4