0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1628783

1628783

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    PHOENIX CONTACT - 1628783 - Sensor Connector, M23 PRO Series, M23, Male, 4 Signal + 3 Power + PE Pos...

  • 数据手册
  • 价格&库存
1628783 数据手册
https://www.phoenixcontact.com/gb/products/1628783 Coupler connector - M23-7EP198A9L23S - 1628783 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Coupler connector, M23 PRO, straight, shielded: yes, for standard and ONECLICK fast locking system, M23, No. of pos.: 4+3+PE, type of contact: Pin, Crimp connection, cable diameter range: 7.5 mm ... 12 mm Your advantages  Solutions with cross-manufacturer compatibility for standard and fast locking systems  Modern, consistent design for highly convenient operation  Easy, cost-effective cable assembly: uniform shielding of M17 to M40 Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626763118 Weight per Piece (excluding packing) 130.000 g Custom tariff number 85366990 Sales Key ABRCII Technical data Temperature range Ambient temperature -40 °C ... 105 °C (see to derating) max. operating temperature 125 °C (DIN EN 60512-9-2 / 1000 h) Standards and Regulations Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. 01/18/2022   Page 1 / 6 https://www.phoenixcontact.com/gb/products/1628783 Coupler connector - M23-7EP198A9L23S - 1628783 Technical data Standards and Regulations The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. • The products are suitable for applications in plant, controller, and electrical device engineering. • When operating the connectors in outdoor applications, they must be separately protected against environmental influences. • Assembled products may not be manipulated or improperly opened. • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). • When using the product in direct connection with third-party manufacturers, the user is responsible. • For operating voltages > 50 V AC, conductive connector housings must be grounded • Ensure that the protective or functional ground has been properly connected. • VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector • Only use tools recommended by Phoenix Contact • The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product. • Operate the connector only when it is fully plugged in and interlocked. • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. • Observe the minimum bending radius of the cable. Lay the cable without twisting it. • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). Data of the insulating body Note Order information: Order crimp contacts 4 x Ø 1 mm, 4 x Ø 2 mm separately Insulator material PA 6.6 Contact connection method Crimp connection Type of contacts Pin Application Power Number of positions 8 Contact diameter of power contacts 2 mm Litz wire cross section of power contacts min. 0.25 mm² Litz wire cross section of power contacts max. 4 mm² Rated current for power contacts 30 A Note for max. connection cross section Rated voltage 630 V 01/18/2022   Page 2 / 6 https://www.phoenixcontact.com/gb/products/1628783 Coupler connector - M23-7EP198A9L23S - 1628783 Technical data Data of the insulating body Rated surge voltage 6 kV Overvoltage category III Degree of pollution 3 Contact diameter of signal contacts 1 mm Litz wire cross section of signal contacts min. 0.06 mm² Litz wire cross section of signal contacts max. 1 mm² Nominal current per signal contact 9A Note for max. connection cross section Rated voltage of signal contact 250 V Rated surge voltage 4 kV Overvoltage category III Degree of pollution 3 Note for max. connection cross section Installation height 3000 m Housing data Housing material GD-Zn Type of locking for standard and ONECLICK fast locking system Degree of protection (when plugged in) IP66 / IP68 (2 m / 24 h) Thread type M23 Cable seal data Cable diameter 7.5 mm ... 12 mm Sealing material FKM Environmental Product Compliance China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values Drawings D3 C 4 B A1 Diagram I [A] Schematic diagram 45 40 35 30 25 20 15 10 5 0 1 1 0 2 = 3x4mm 10 20 30 40 50 60 70 80 90 100 110 120 130  [°C] I = current strength, T = ambient temperature 01/18/2022   Page 3 / 6 https://www.phoenixcontact.com/gb/products/1628783 Coupler connector - M23-7EP198A9L23S - 1628783 Dimensional drawing Ø29,3 M23x1 71,35 Dimensional drawing Classifications eCl@ss eCl@ss 10.0.1 27440102 eCl@ss 11.0 27440102 eCl@ss 9.0 27440102 ETIM ETIM 7.0 EC002635 UNSPSC UNSPSC 18.0 39121413 UNSPSC 19.0 39121413 UNSPSC 20.0 39121413 UNSPSC 21.0 39121413 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approval details UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  E468743-20190627     Nominal voltage UN 600 V Nominal current IN 24 A 01/18/2022   Page 4 / 6 https://www.phoenixcontact.com/gb/products/1628783 Coupler connector - M23-7EP198A9L23S - 1628783 Approvals     mm²/AWG/kcmil 10 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  E468743-20190627     Nominal voltage UN 600 V Nominal current IN 20 A mm²/AWG/kcmil 10 cULus Listed       Accessories Accessories Crimp contact Crimp contact - SF-20KP011 - 1050147 Crimp contact, turned, contact diameter: 2 mm, crimp range: 0.25 mm² ... 1 mm²     Crimp contact - SF-20KP012 - 1050205 Crimp contact     Crimp contact - SF-20KP013 - 1050210 Crimp contact     01/18/2022   Page 5 / 6 https://www.phoenixcontact.com/gb/products/1628783 Coupler connector - M23-7EP198A9L23S - 1628783 Accessories Crimp contact - ST-10KP010 - 1618255 Crimp contact, turned, Single contact, contact diameter: 1 mm, crimp range: 0.06 mm² ... 0.25 mm²     Crimp contact - ST-10KP035 - 1618458 Crimp contact, turned, contact diameter: 1 mm, crimp range: 0.25 mm² ... 1 mm²     Protective cover Protective cap - RC-Z2058 - 1604223 Plastic protection cap for connectors with M23 knurled nut     Metal protective cap - SC-Z2319 - 1605456 Metal protection cap for power connectors with M23 external thread     Phoenix Contact 2022 © - all rights reserved http://www.phoenixcontact.com 01/18/2022   Page 6 / 6
1628783 价格&库存

很抱歉,暂时无法提供与“1628783”相匹配的价格&库存,您可以联系我们找货

免费人工找货