HEAVYCON male insert, K6/12 series, with 6 power (axial screw connection) and 12 control contacts (screw
connection)
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
149.4 g
Custom tariff number
85366990
Country of origin
Germany
Technical data
General
Note
For HEAVYCON ADVANCE and HEAVYCON housing of type B16/B32,
axial connection for 2 mm Allen wrench
Connection method
Axial screw connection (power contacts)
Signal Screw connection
Tightening torque
1.5 Nm (Power contacts 2.5 - 4 mm²)
0.8 Nm (control contacts)
2 Nm (Power contacts 6 - 8 mm²)
2 Nm (Power contacts 6 - 8 mm²)
Screwdriver blade
0.5 x 3.5 mm (control contacts)
Degree of pollution
3
Overvoltage category
III
Number of positions
6+12+PE
No. of power contacts
6
No. of control contacts
12
Insertion/withdrawal cycles
≥ 500
Size
B16
04/11/2016 Page 1 / 5
https://www.phoenixcontact.com/us/products/1636350
Contact insert - HC-K 6/12-ESTS - 1636350
Technical data
General
Conductor cross section
2.5 mm² ... 8 mm² (The cross section specification refers to the geometric
cross section of the cable used)
0.2 mm² ... 2.5 mm²
Connection cross section AWG
12 ... 10
24 ... 14 (control contacts)
Stripping length of the individual wire
8 mm +1 (Power contacts 6 - 8 mm²)
10 mm (control contacts)
5 mm +1 (Power contacts 2.5 - 4 mm²)
Wire diameter including insulation
6.1 mm (Max., power contacts)
Assembly instructions
-The axial screw connection must be established using a 2 mm Allen
wrench.
-Use only stranded wires for axial screw connection.
-Plug-in connections may only be operated only when there is no load/
voltage.
Connection
Note regarding axial connection technology:
Only for stranded wires. The conductor cross sections stated refer to the
geometric cross section of the cable used.
Use of cables with a geometric cross section very different from that of the
cable's nominal cross section should be checked before use.
The wiring space of the axial screw method is designed for fine strand
cables according to VDE 0295 class 5. Deviating cable structures (e.g.
class 6 cables) should be checked before use.
Connection
Before starting to connect, ensure that the tapered screw is turned
back all the way (chamber is open). The cables must not be twisted.
The cores should be slid to the limit stop in the contact chamber (until
insulation touches contact). Hold cores in position and use socket wrench
to tighten. The used core end should be cut off before connecting again.
The connection screw may only be retightened once to prevent the
strands from breaking. To prevent damage to the contact, the core / cable
should be mechanically intercepted at an appropriate distance from the
connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06
contains information on how to do this correctly.
Ambient conditions
Ambient temperature (operation)
-40 °C ... 125 °C
Material data
Flammability rating according to UL 94
V0
Contact material
Cu alloy
Material of contact surface, power contact
Ag
Material of contact surface, control contact
Ag
Contact carrier material
PC
Electrical characteristics
Rated voltage for power contacts
230/400 V
Rated voltage (III/3)
Power 690 V
04/11/2016 Page 2 / 5
https://www.phoenixcontact.com/us/products/1636350
Contact insert - HC-K 6/12-ESTS - 1636350
Technical data
Electrical characteristics
Signal 230 V (Conductor-PE)
Signal 400 V (Conductor-Conductor)
Rated surge voltage
8 kV (power contacts)
4 kV (control contacts)
Rated current
40 A (power contacts)
10 A (control contacts)
Standards and Regulations
Connection in acc. with standard
CSA
Flammability rating according to UL 94
V0
Classifications
eCl@ss
eCl@ss 4.0
27140816
eCl@ss 4.1
27140816
eCl@ss 5.0
27143424
eCl@ss 5.1
27143424
eCl@ss 6.0
27143424
eCl@ss 7.0
27440209
eCl@ss 8.0
27440205
eCl@ss 9.0
27440205
ETIM
ETIM 2.0
EC000438
ETIM 3.0
EC000438
ETIM 4.0
EC000438
ETIM 5.0
EC000438
UNSPSC
UNSPSC 6.01
30211923
UNSPSC 7.0901
39121522
UNSPSC 11
39121522
UNSPSC 12.01
39121522
UNSPSC 13.2
39121522
Approvals
Approvals
04/11/2016 Page 3 / 5
https://www.phoenixcontact.com/us/products/1636350
Contact insert - HC-K 6/12-ESTS - 1636350
Approvals
Approvals
CSA / UL Recognized / EAC / EAC / GL
Ex Approvals
Approvals submitted
Approval details
CSA
mm²/AWG/kcmil
13-7
Nominal current IN
40 A
Nominal voltage UN
600 V
UL Recognized
Nominal voltage UN
600 V
EAC
EAC
GL
Drawings
04/11/2016 Page 4 / 5
https://www.phoenixcontact.com/us/products/1636350
Contact insert - HC-K 6/12-ESTS - 1636350
Schematic diagram
Dimensional drawing
77,5
3
4
5
6
Ø3,3
20
21
22
14
15
16
5
36
2
14
1
27
17
18
19
11
12
13
68,5
Panel cutout
Connector pin assignment, connection side
Diagram
Dimensional drawing
60
2
50
3
47,2
Operating current [A]
70
40
30
20
1 = 4 mm
2
10 2 = 6 mm
2
0
3 = 10 mm
20
1
2
40
60
80
100
77,5
27
84,5
34
120
Ambient temperature [°C]
Dimensional drawing
Derating curve
Schematic diagram
Axial connection
Phoenix Contact 2016 © - all rights reserved