0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1636350

1636350

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    INSERT MALE 6+12POS+1GND SCREW

  • 数据手册
  • 价格&库存
1636350 数据手册
https://www.phoenixcontact.com/us/products/1636350 Contact insert - HC-K 6/12-ESTS - 1636350 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) HEAVYCON male insert, K6/12 series, with 6 power (axial screw connection) and 12 control contacts (screw connection) Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 149.4 g Custom tariff number 85366990 Country of origin Germany Technical data General Note For HEAVYCON ADVANCE and HEAVYCON housing of type B16/B32, axial connection for 2 mm Allen wrench Connection method Axial screw connection (power contacts) Signal Screw connection Tightening torque 1.5 Nm (Power contacts 2.5 - 4 mm²) 0.8 Nm (control contacts) 2 Nm (Power contacts 6 - 8 mm²) 2 Nm (Power contacts 6 - 8 mm²) Screwdriver blade 0.5 x 3.5 mm (control contacts) Degree of pollution 3 Overvoltage category III Number of positions 6+12+PE No. of power contacts 6 No. of control contacts 12 Insertion/withdrawal cycles ≥ 500 Size B16 04/11/2016   Page 1 / 5 https://www.phoenixcontact.com/us/products/1636350 Contact insert - HC-K 6/12-ESTS - 1636350 Technical data General Conductor cross section 2.5 mm² ... 8 mm² (The cross section specification refers to the geometric cross section of the cable used) 0.2 mm² ... 2.5 mm² Connection cross section AWG 12 ... 10 24 ... 14 (control contacts) Stripping length of the individual wire 8 mm +1 (Power contacts 6 - 8 mm²) 10 mm (control contacts) 5 mm +1 (Power contacts 2.5 - 4 mm²) Wire diameter including insulation 6.1 mm (Max., power contacts) Assembly instructions -The axial screw connection must be established using a 2 mm Allen wrench. -Use only stranded wires for axial screw connection. -Plug-in connections may only be operated only when there is no load/ voltage. Connection Note regarding axial connection technology: Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used. Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use. The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use. Connection Before starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. Ambient conditions Ambient temperature (operation) -40 °C ... 125 °C Material data Flammability rating according to UL 94 V0 Contact material Cu alloy Material of contact surface, power contact Ag Material of contact surface, control contact Ag Contact carrier material PC Electrical characteristics Rated voltage for power contacts 230/400 V Rated voltage (III/3) Power 690 V 04/11/2016   Page 2 / 5 https://www.phoenixcontact.com/us/products/1636350 Contact insert - HC-K 6/12-ESTS - 1636350 Technical data Electrical characteristics Signal 230 V (Conductor-PE) Signal 400 V (Conductor-Conductor) Rated surge voltage 8 kV (power contacts) 4 kV (control contacts) Rated current 40 A (power contacts) 10 A (control contacts) Standards and Regulations Connection in acc. with standard CSA Flammability rating according to UL 94 V0 Classifications eCl@ss eCl@ss 4.0 27140816 eCl@ss 4.1 27140816 eCl@ss 5.0 27143424 eCl@ss 5.1 27143424 eCl@ss 6.0 27143424 eCl@ss 7.0 27440209 eCl@ss 8.0 27440205 eCl@ss 9.0 27440205 ETIM ETIM 2.0 EC000438 ETIM 3.0 EC000438 ETIM 4.0 EC000438 ETIM 5.0 EC000438 UNSPSC UNSPSC 6.01 30211923 UNSPSC 7.0901 39121522 UNSPSC 11 39121522 UNSPSC 12.01 39121522 UNSPSC 13.2 39121522 Approvals Approvals 04/11/2016   Page 3 / 5 https://www.phoenixcontact.com/us/products/1636350 Contact insert - HC-K 6/12-ESTS - 1636350 Approvals Approvals CSA / UL Recognized / EAC / EAC / GL Ex Approvals Approvals submitted Approval details CSA      mm²/AWG/kcmil 13-7 Nominal current IN 40 A Nominal voltage UN 600 V UL Recognized      Nominal voltage UN 600 V EAC  EAC  GL  Drawings 04/11/2016   Page 4 / 5 https://www.phoenixcontact.com/us/products/1636350 Contact insert - HC-K 6/12-ESTS - 1636350 Schematic diagram Dimensional drawing 77,5 3 4 5 6 Ø3,3 20 21 22 14 15 16 5 36 2 14 1 27 17 18 19 11 12 13 68,5 Panel cutout Connector pin assignment, connection side Diagram Dimensional drawing 60 2 50 3 47,2 Operating current [A] 70 40 30 20 1 = 4 mm 2 10 2 = 6 mm 2 0 3 = 10 mm 20 1 2 40 60 80 100 77,5 27 84,5 34 120 Ambient temperature [°C] Dimensional drawing Derating curve Schematic diagram Axial connection Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 04/11/2016   Page 5 / 5
1636350 价格&库存

很抱歉,暂时无法提供与“1636350”相匹配的价格&库存,您可以联系我们找货

免费人工找货