VARIOCON
Modular Contact Inserts
1. Short Description
18
16
14
12
8
6
4
2
0
20
40
on
l
0
in
ec
10
60
80
100
10
9
8
7
6
5
4
3
2
1
0
120
Ambient temperature [°C]
0
20
40
60
80
9
8
7
6
5
4
3
2
1
0
20
40
60
80
100
120
Ambient temperature [°C]
10
0
100
Derating curve VC-TFS HC 8 / VC-AML 8/ VC-AMS 8
Derating curve VC-TFS 2 / VC-AML 2/ VC-AMS 2
Load current [A]
Load current[A]
po
20
om
Load current [A]
ne
nt
s.
co
m
The modular contact inserts are based on the triedand-tested COMBICON technology. They are available
with the screw connection system and on the
equipment side also as a solder in version.
The sleeve or mounting contact inserts are snapped
into the correct frames and are then simple to
assemble and mount. The modules are easy to unsnap
with a screwdriver.
All contact inserts can be equipped with coding
profiles. This rules out the possibility of mixing up
several plug connectors.
The modules can be individually labeled using the
corresponding marker cards SK...
120
Ambient temperature [°C]
Derating curve VC-TFS HC 6 / VC-AML 6/ VC-AMS 6
Phoenix Contact GmbH & Co. KG • 32823 Blomberg, Germany
Phone +49 52 35 3-00 • Fax +49 52 35 3-4 12 00 • www.phoenixcontact.de
VARIOCON
Sleeve Contact Insert with
Screw Terminal Blocks
Number of
positions
Contact insert, for sleeve frames
2
6
8
Type
Order No.
Pcs./Pkt.
VC-TFS 2
VC-TFS 6
VC-TFS 8
18 52 84 6
18 53 47 6
18 52 82 0
10
m
Description
CP-HCC 4
Coding section, for VC-...6/8, is inserted into the groove on the header,
red insulating material
CP-MSTB
nt
Technical data
20
400
III / 3
6/I
8
250
III / 3
4/I
8
160
III / 3
2.5 / I
0.2 - 4.0 / 0.2 - 1.5
24 - 12 / 24 - 16
0.14 - 1.5 / 0.14 - 1.5
28 - 16 / 28 - 16
0.14 - 1.5 / 0.14 - 1.5
28 - 16 / 28 - 16
0.2 - 2.5 / 0.2 - 1.5
24 - 14 / 24 - 16
0.25 - 1.5
24 - 16
0.5 - 2.5
20 - 14
PA
V0
0.14 - 0.5 / 0.14 - 0.75 0.14 - 0.5 / 0.14 - 0.75
28 - 20 / 28 - 18
28 - 20 / 28 - 18
0.25 - 0.34
0.25 - 0.34
24 - 20
24 - 20
0.5
0.5
20
20
PA
PA
V0
V0
600 / 20 / 30-10
600 / 20 / 30-10
0.5 - 0.6
300 / 8 / 30-14
300 / 8 / 30-14
0.22 - 0.25
300 / 8 / 30-14
300 / 8 / 30-14
0.22 - 0.25
A/a
A/a
A/a
21,7
15
14,7
VC-TFS 2
7,5
21,7
15
26,6
26,6
26,6
15
100
VC-TFS 8
ne
om
in
ec
on
l
30,6
17 34 63 4
VC-TFS 6
[kV] / –
[mm2] / [mm2]
AWG / AWG
Multiple connection (2 conductors with same cross section)
Solid / Stranded
[mm2] / [mm2]
AWG / AWG
Stranded with ferrule without plastic sleeve
[mm2] / [mm2]
AWG / AWG
Stranded with TWIN ferrule with plastic sleeve
[mm2] / [mm2]
AWG / AWG
Insulating material
Inflammability class in acc. with UL 94
Approval data (UL and CUL)
Nom. voltage / nom. current / conduc. cross sec.
UL: [V] / [A] / AWG
CUL: [V] / [A] / AWG
Torque
[Nm]
Approvals
100
VC-TFS 2
[A]
[V]
po
Design
Technical data in accordance with IEC/ DIN VDE
Rated current
Rated voltage
Surge voltage category / contamination class
Rated surge voltage / insulation material group
Connection capacity
Solid / Stranded
16 00 02 7
s.
Coding section, for VC-...2, is inserted into the groove on the
connector and header, red insulating material
co
Accessories
8,3
5
VC-TFS 6
Phoenix Contact page 2 of 5
5
8,3
VC-TFS 8
3,5
VARIOCON
Mounting Contact Insert with
Screw Terminal Blocks
Contact insert, for panel mounting frames
2
6
8
Type
Order No.
Pcs./Pkt.
VC-AMS 2
VC-AMS 6
VC-AMS 8
18 53 52 8
18 54 01 9
18 54 02 2
10
CP-HCC 4
Coding section, for VC-...6/8, is inserted into the groove on the header,
red insulating material
CP-MSTB
nt
Technical data
po
20
400
III / 3
6/I
8
250
III / 3
4/I
8
160
III / 3
2.5 / I
0.2 - 4.0 / 0.2 - 1.5
24 - 12 / 24 - 16
0.14 - 1.5 / 0.14 - 1.5
28 - 16 / 28 - 16
0.14 - 1.5 / 0.14 - 1.5
28 - 16 / 28 - 16
0.2 - 2.5 / 0.2 - 1.5
24 - 14 / 24 - 16
0.25 - 1.5
24 - 16
0.5 - 2.5
20 - 14
PA
V0
0.14 - 0.5 / 0.14 - 0.75 0.14 - 0.5 / 0.14 - 0.75
28 - 20 / 28 - 18
28 - 20 / 28 - 18
0.25 - 0.34
0.25 - 0.34
24 - 20
24 - 20
0.5
0.5
20
20
PA
PA
V0
V0
600 / 20 / 30-10
600 / 20 / 30-10
0.5 - 0.6
300 / 8 / 30-14
300 / 8 / 30-14
0.22 - 0.25
300 / 8 / 30-14
300 / 8 / 30-14
0.22 - 0.25
A/a
A/a
A/a
15
13,9
34,6
15
5,5
5,5
22
13,9
2,4
34,6
2,4
om
in
ec
22
100
VC-AMS 8
[kV] / –
on
l
2,4
15
5,5
13,9
29,8
17 34 63 4
VC-AMS 6
[A]
[V]
[mm2] / [mm2]
AWG / AWG
Multiple connection (2 conductors with same cross section)
Solid / Stranded
[mm2] / [mm2]
AWG / AWG
Stranded with ferrule without plastic sleeve
[mm2] / [mm2]
AWG / AWG
Stranded with TWIN ferrule with plastic sleeve
[mm2] / [mm2]
AWG / AWG
Insulating material
Inflammability class in acc. with UL 94
Approval data (UL and CUL)
Nom. voltage / nom. current / conduc. cross sec.
UL: [V] / [A] / AWG
CUL: [V] / [A] / AWG
Torque
[Nm]
Approvals
100
VC-AMS 2
ne
Design
Technical data in accordance with IEC/ DIN VDE
Rated current
Rated voltage
Surge voltage category / contamination class
Rated surge voltage / insulation material group
Connection capacity
Solid / Stranded
16 00 02 7
s.
Coding section, for VC-...2, is inserted into the groove on the
connector and header, red insulating material
co
Accessories
22
Number of
positions
m
Description
3,5
3,75
VC-AMS 2
7,5
3,75
2,5
VC-AMS 6
Phoenix Contact page 3 of 5
10
2,5
2,25
VC-AMS 8
10,5
2,25
VARIOCON
Mounting Contact Insert
with 90° Angled Solder-In Pins
Number of
positions
Contact insert, for mounting panel frames
2
6
8
Type
Order No.
Pcs./Pkt.
VC-AML 2
VC-AML 6
VC-AML 8
18 52 85 9
18 53 53 1
18 52 83 3
10
m
Description
CP-HCC 4
Coding section, for VC-...6/8, is inserted into the groove on the header,
red insulating material
CP-MSTB
nt
Technical data
20
400
III / 3
6/I
PA
V0
8
250
III / 3
4/I
PA
V0
8
160
III / 3
2.5 / I
PA
V0
600 / 20 / –
600 / 20 / –
300 / 8 / –
300 / 8 / –
300 / 8 / –
300 / 8 / –
A/a
A/a
A/a
7
4
15,9
3,5
7,5
VC-AML 2
1,3
7,5
2,4
3,4
1,3
7,5
28,2
15
20,71
2,4
15
20,71
3,5
100
VC-AML 8
0.8 x 0.8
1.2
28,2
3,4
3,4
15,9
17 34 63 4
VC-AML 6
0.8 x 0.8
1.4
po
om
in
ec
on
l
20,71
2,4
15
100
VC-AML 2
2 x 0.8
1.4
ne
Design
Dimensions solder-in pins
[mm] x [mm]
Hole diameter
[mm]
Technical data in accordance with IEC/ DIN VDE
Rated current
[A]
Rated voltage
[V]
Surge voltage category / contamination class
Rated surge voltage / insulation material group
[kV] / –
Insulating material
Inflammability class in acc. with UL 94
Approval data (UL and CUL)
Nom. voltage / nom. current / conduc. cross sec.
UL: [V] / [A] / AWG
CUL: [V] / [A] / AWG
Approvals
28,2
16 00 02 7
s.
Coding section, for VC-...2, is inserted into the groove on the
connector and header, red insulating material
co
Accessories
5
7
15,9
3,5
4
VC-AML 6
1,3
7,5
3,5
7
VC-AML 8
10,5
7,5
3,5
7
Drilling diagram VC-AML 2
7
Drilling diagram VC-AML 6
Phoenix Contact page 4 of 5
1,2
1,4
3,5
7,5
1,2
1,4
3,5
1,4
3,5
7,5
7,5
1,4
5 5
7
Drilling diagram VC-AML 8
4
VARIOCON
Mounting Contact Insert
with Straight Solder-In Pins
Number of
positions
2
6
8
Order No.
Pcs./Pkt.
VC-AMLV 2
VC-AMLV 6
VC-AMLV 8
18 84 97 9
18 84 87 2
18 84 88 5
10
CP-HCC 4
Coding section, for VC-...6/8, is inserted into the groove on the header,
red insulating material
CP-MSTB
nt
Technical data
20
400
III / 3
6/I
PA
V0
8
250
III / 3
4/I
PA
V0
8
160
III / 3
2.5 / I
PA
V0
600 / 20 / –
600 / 20 / –
300 / 8 / –
300 / 8 / –
300 / 8 / –
300 / 8 / –
A/a
A/a
A/a
po
om
5
2,25
VC-AMLV 6
10,5
11,06
5 5
5,4
5,4
1,2
11,06
7,5
1,5
7,62 8,85
2,5
10,5
VC-AMLV 8
3,75
3,75
3,5
5,4 11,06
5
1,2
VC-AMLV 2
2,5
3,5
Drilling diagram VC-AMLV 2
Drilling diagram VC-AMLV 6
Phoenix Contact page 5 of 5
TNR: 5126138-01
5,4 11,06
Drilling diagram VC-AMLV 8
Phoenix Contact 21.03.03
3,3
7,5
3,3
3,75
15
20,71
15
28,6
20,71
28,6
28,5
3,6
7,62 8,85
100
VC-AMLV 8
0.8 x 0.8
1.2
2,4
2,4
15
17 34 63 4
VC-AMLV 6
0.8 x 0.8
1.4
in
ec
on
l
20,71
100
VC-AMLV 2
2 x 0.8
1.4
ne
Design
Dimensions solder-in pins
[mm] x [mm]
Hole diameter
[mm]
Technical data in accordance with IEC/ DIN VDE
Rated current
[A]
Rated voltage
[V]
Surge voltage category / contamination class1)
Rated surge voltage / insulation material group
[kV] / –
Insulating material
Inflammability class in acc. with UL 94
Approval data (UL and CUL)
Nom. voltage / nom. current / conduc. cross sec.
UL: [V] / [A] / AWG
CUL: [V] / [A] / AWG
Approvals
1
) In the 2 and 6-pos. constellation, as well as in the 2 and 8-pos.
versions, there is a reduction in the air and creepage distances.
The contamination class is thus reduced to 2 and the surge voltage
category to II.
2,4
16 00 02 7
s.
Coding section, for VC-...2, is inserted into the groove on the
connector and header, red insulating material
co
Accessories
www.phoenixcontact.de
Contact insert, for panel mounting frames
Type
m
Description