VARIOCON protective cover for sleeve housing, with IP50 protection, type 4, max. tightening torque: 1.6 Nm
Your advantages
Easy mounting
Contact inserts are protected when not plugged in
Key Commercial Data
Packing unit
1 pc
Minimum order quantity
5 pc
GTIN
GTIN
4017918908447
Weight per Piece (excluding packing)
23.340 g
Custom tariff number
39269097
Country of origin
Poland
Technical data
Dimensions
Length
104 mm
Width
33 mm
Height
22.9 mm
Ambient conditions
Degree of protection
IP65
Ambient temperature (operation)
-40 °C ... 80 °C
12/17/2019 Page 1 / 5
https://www.phoenixcontact.com/us/products/1886757
Protective covers - VC-SD-T4 - 1886757
Technical data
General
Size
VC4
Type
For sleeve housing
Material
PA
Flammability rating according to UL 94
V0
Seal present
no
Assembly instructions
Tightening torque 1.6 Nm
Mounting type
Screw locking
Standards and Regulations
Flammability rating according to UL 94
V0
Safety note
WARNING: The connectors may not be plugged in or disconnected under
load. Ignoring the warning or improper use may damage persons and/or
property.
• WARNING: Commission properly functioning products only. The products
must be regularly inspected for damage. Decommission defective products
immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate
the product. They must observe the following safety notes. The qualified
personnel must be familiar with the basics of electrical engineering. They
must be able to recognize and prevent danger. The relevant symbol on the
packaging indicates that only personnel familiar with electrical engineering
are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and
electrical device engineering.
• When operating the connectors in outdoor applications, they must be
separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the
standards listed (e.g. the ones listed in the product accessories online at
phoenixcontact.com/products).
• When using the product in direct connection with third-party
manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must
be grounded
• Ensure that the protective or functional ground has been properly
connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are
applicable when combining several circuits in a cable and/or connector
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
12/17/2019 Page 2 / 5
https://www.phoenixcontact.com/us/products/1886757
Protective covers - VC-SD-T4 - 1886757
Technical data
Standards and Regulations
• The installation notes/Design In documents online on the download page
at phoenixcontact.com/products must be observed for this product.
• Use a protective cap to protect connectors that are not in use. The
suitable accessories are available online in the accessory section of the
product at phoenixcontact.com/products
• Operate the connector only when it is fully plugged in.
• Ensure that when laying the cable, the tensile load on the connectors
does not exceed the upper limit specified in the standards.
• Observe the minimum bending radius of the cable. Lay the cable without
twisting it.
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Dimensional drawing
Classifications
eCl@ss
eCl@ss 4.0
27141200
12/17/2019 Page 3 / 5
https://www.phoenixcontact.com/us/products/1886757
Protective covers - VC-SD-T4 - 1886757
Classifications
eCl@ss
eCl@ss 4.1
27141200
eCl@ss 5.0
27142100
eCl@ss 5.1
27142100
eCl@ss 6.0
27261200
eCl@ss 7.0
27440208
eCl@ss 8.0
27440208
eCl@ss 9.0
27440208
ETIM
ETIM 2.0
EC000241
ETIM 3.0
EC002040
ETIM 4.0
EC002040
ETIM 5.0
EC002314
ETIM 6.0
EC002314
ETIM 7.0
EC002314
UNSPSC
UNSPSC 6.01
30212113
UNSPSC 7.0901
39121712
UNSPSC 11
39121712
UNSPSC 12.01
39121712
UNSPSC 13.2
39121421
UNSPSC 18.0
39121421
UNSPSC 19.0
39121421
UNSPSC 20.0
39121421
UNSPSC 21.0
39121421
Approvals
Approvals
Approvals
EAC
Ex Approvals
Approval details
12/17/2019 Page 4 / 5
https://www.phoenixcontact.com/us/products/1886757
Protective covers - VC-SD-T4 - 1886757
Approvals
EAC
B.01742
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com
12/17/2019 Page 5 / 5
很抱歉,暂时无法提供与“1886757”相匹配的价格&库存,您可以联系我们找货
免费人工找货