Extract from the online
catalog
FKC 2,5/10-STF
Order No.: 1910607
The figure shows a 10-position version of the product
s.
Plug component, Nominal current: 12 A, Rated voltage (III/2): 320 V,
Pitch: 5 mm, Color: green, Metal surface: Sn
co
m
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1910607
Commercial data
4017918175382
Note
Made-to-order
sales group
E111
Pack
50 pcs.
Customs tariff
85366990
po
om
Weight/Piece
0.01971 KG
Page 211 (CC-2009)
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
on
l
in
ec
Catalog page information
WEEE/RoHS-compliant since:
01/01/2003
ne
GTIN (EAN)
nt
Product notes
Technical data
Dimensions / positions
Pitch
5 mm
Dimension a
45 mm
Number of positions
10
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 1 / 4
Jun 29, 2010
FKC 2,5/10-STF Order No.: 1910607
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1910607
Rated surge voltage (III/3)
4 kV
Rated surge voltage (III/2)
4 kV
Rated surge voltage (II/2)
4 kV
Rated voltage (III/2)
320 V
Rated voltage (II/2)
630 V
Connection in acc. with standard
EN-VDE
Nominal current IN
12 A
Nominal voltage UN
250 V
Nominal cross section
2.5 mm²
Maximum load current
12 A
Insulating material
PA
Inflammability class acc. to UL 94
V0
Internal cylindrical gage
A2
Stripping length
10 mm
Nominal voltage, UL/CUL Use Group B
250 V
Nominal current, UL/CUL Use Group B
10 A
in
ec
Connection data
300 V
10 A
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section stranded min.
0.2 mm²
Conductor cross section stranded max.
2.5 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve min.
0.25 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve max.
2.5 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve min.
0.25 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve max.
2.5 mm²
Conductor cross section AWG/kcmil min.
24
Conductor cross section AWG/kcmil max
12
2 conductors with same cross section, stranded,
TWIN ferrules with plastic sleeve, min.
0.5 mm²
on
l
Conductor cross section solid min.
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
nt
ne
om
Nominal current, UL/CUL Use Group D
po
Nominal voltage, UL/CUL Use Group D
co
I
s.
Insulating material group
m
Technical data
Page 2 / 4
Jun 29, 2010
FKC 2,5/10-STF Order No.: 1910607
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1910607
2 conductors with same cross section, stranded,
TWIN ferrules with plastic sleeve, max.
1 mm²
Minimum AWG according to UL/CUL
26
Maximum AWG according to UL/CUL
12
CB, CSA, CUL, UL, VDE-PZI
co
Certification
Nominal current IN
10 A
AWG/kcmil
24-12
ne
CUL
nt
300 V
s.
CSA
Nominal voltage UN
m
Certificates / Approvals
300 V
po
Nominal voltage UN
Nominal current IN
10 A
26-12
om
AWG/kcmil
UL
Nominal current IN
AWG/kcmil
300 V
10 A
26-12
on
l
Diagrams/Drawings
in
ec
Nominal voltage UN
Dimensioned drawing
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 3 / 4
Jun 29, 2010
FKC 2,5/10-STF Order No.: 1910607
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1910607
Address
s.
co
m
PHOENIX CONTACT Deutschland GmbH
Flachsmarktstr. 8
32825 Blomberg,Germany
Phone +49 5235 3 12000
Fax +49 5235 3 41200
http://www.phoenixcontact.de
on
l
in
ec
om
po
ne
nt
© 2010 Phoenix Contact
Technical modifications reserved;
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 4 / 4
Jun 29, 2010
很抱歉,暂时无法提供与“1910607”相匹配的价格&库存,您可以联系我们找货
免费人工找货