co
s.
nt
in
ec
COMBICON Select
om
po
ne
The new PCB terminal blocks PT 2,5/...-5,0 are
characterized by the proven screw connection with
highly flexible conductor protection and the extremely
generous clamping space. Solid and stranded
conductors up to 4 mm2 can be connected.
Thanks to its compact external dimensions, the
PT 2,5/...-5,0 is particularly suitable for building
automation and telecommunications applications where
space is critical.
The PT 2,5/... is also available with a 7.5 mm pitch.
Customized labeling of the terminal blocks is possible.
m
COMBICON compact
Printed Circuit Screw Termination Blocks
PT 2,5/… with a 5.0 and 7.5 mm Pitch
on
l
The COMBICON search engine with CAD downloading
COMBICON Select – the printed circuit board connection software
supports your workflow from the PCB and housing layout to the
ordering process with:
–Systematic and fast selection of products
–Universal Internet aided engineering with extensive
CAD downloading
–Easy-to-use e-shopping functions.
select.phoenixcontact.com/combicon
Phoenix Contact GmbH & Co. KG • 32823 Blomberg, Germany
Phone +49 52 35 3-00 • Fax +49 52 35 3-4 12 00 • www.phoenixcontact.com
Local Contact: www.phoenixcontact.com/salesnetwork
PHOENIX CONTACT page 1 of 5
Printed Circuit
Screw Termination Blocks
PT 2,5/…-5,0-H
5.0 mm Pitch
Dim.
a
[mm]
2
3
4
Order No.
Pcs./Pkt.
5
10
15
PT 2,5/2-5,0-H
PT 2,5/3-5,0-H
PT 2,5/4-5,0-H
19 35 77 6
19 35 78 9
19 35 79 2
250
250
250
5
6
7
20
25
30
PT 2,5/5-5,0-H
PT 2,5/6-5,0-H
PT 2,5/7-5,0-H
19 35 80 2
19 35 81 5
19 35 82 8
100
100
100
8
9
10
35
40
45
PT 2,5/8-5,0-H
PT 2,5/9-5,0-H
PT 2,5/10-5,0-H
19 35 83 1
19 35 84 4
19 35 85 7
100
100
100
11
12
13
50
55
60
PT 2,5/11-5,0-H
PT 2,5/12-5,0-H
PT 2,5/13-5,0-H
19 35 86 0
19 35 87 3
19 35 88 6
50
50
50
14
15
16
65
70
75
PT 2,5/14-5,0-H
PT 2,5/15-5,0-H
PT 2,5/16-5,0-H
19 35 89 9
19 35 90 9
19 35 91 2
50
50
50
SZS 0,6 x 3,5
SZK PH 1
12 05 05 3
12 05 15 0
10
10
co
s.
po
(1) Screwdriver
m
Type
nt
Printed circuit screw termination blocks with
housing interlocking, 5 mm pitch, color: green,
connection direction horizontal to the PCB
No. of pos.
ne
Description
Technical data
om
Dimensions
Pitch
[mm]
Hole diameter
[mm]
Pin dimensions
[mm]x[mm]
Technical data in accordance with IEC/ DIN VDE
Insulating material group
–
Surge voltage category / contamination class
–/–
Rated voltage
[V]
Rated surge voltage
[kV]
Nominal current / cross section
[A]/[mm2]
Maximum load current / cross section
[A]/[mm2]
Connection capacity
Solid / stranded / conductor sizes
[mm2]/[mm2]/AWG
Stranded with ferrule without / with plastic sleeve
[mm2]
Multiple connection (2 conductors with same cross section)
Solid / stranded
[mm2]
Stranded with ferrule without plastic sleeve
[mm2]
Stranded with TWIN ferrule with plastic sleeve
[mm2]
Stripping length
[mm]
Internal cylindrical gauge (IEC 60 947-1)
–
Thread
–
Torque
[Nm]
Insulating material
Inflammability class in acc. with UL 94
Approval data (UL/CUL and CSA)
Nominal voltage / current / conductor sizes
UL/CUL: [V]/[A]/AWG
CSA: [V]/[A]/AWG
1) When conductors with cross sections over 4 mm2 are connected,
appropriate measures must be taken in order to protect the soldered
connection and the PCB against mechanical stresses caused by
connected conductors.
see description
5.0
1.3
∅ 1.0
I
III / 2
320
4
24 / 2.5
32 / 4.0
in
ec
III / 3
250
4
II / 2
630
4
on
l
0.5 - 61) / 0.5 - 4 / 20- 10
0.5 - 2.5 / 0.5 - 2.5
0.5 - 1.5 / 0.5 - 1.5
0.25 - 0.752)
0.5 - 1.52)
6.5
A3/B3
M3
0.5
PA
V0
300 / 20 / 20 - 12
––
2) When using ferrules, 250 V can only be achieved in connection with
surge voltage category / contamination class II / 2.
9
3 ,6
a + 5
a
4 ,5
4 ,1
1 ,3
1 3 ,5
5
4 ,5
2 ,5
5
a
PHOENIX CONTACT page 2 of 5
Printed Circuit
Screw Termination Blocks
PT 2,5/…-5,0-V
5.0 mm Pitch
Dim.
a
[mm]
2
3
4
Order No.
Pcs./Pkt.
5
10
15
PT 2,5/2-5,0-V
PT 2,5/3-5,0-V
PT 2,5/4-5,0-V
19 87 72 4
19 87 73 7
19 87 74 0
250
250
250
5
6
7
20
25
30
PT 2,5/5-5,0-V
PT 2,5/6-5,0-V
PT 2,5/7-5,0-V
19 87 75 3
19 87 76 6
19 87 77 9
100
100
100
8
9
10
35
40
45
PT 2,5/8-5,0-V
PT 2,5/9-5,0-V
PT 2,5/10-5,0-V
19 87 78 2
19 87 79 5
19 87 80 5
100
100
100
11
12
13
50
55
60
PT 2,5/11-5,0-V
PT 2,5/12-5,0-V
PT 2,5/13-5,0-V
19 87 81 8
19 87 82 1
19 87 83 4
50
50
50
14
15
16
65
70
75
PT 2,5/14-5,0-V
PT 2,5/15-5,0-V
PT 2,5/16-5,0-V
19 87 84 7
19 87 85 0
19 87 86 3
50
50
50
SZS 0,6 x 3,5
SZK PH 1
12 05 05 3
12 05 15 0
10
10
co
s.
po
(1) Screwdriver,
m
Type
nt
Printed circuit screw termination blocks with
housing interlocking, 5 mm pitch, color: green,
connection direction vertical to the PCB
No. of pos.
ne
Description
Technical data
see description
5.0
1.3
∅ 1.0
om
Dimensions
Pitch
[mm]
Hole diameter
[mm]
Pin dimensions
[mm]x[mm]
Technical data in accordance with IEC/ DIN VDE
Insulating material group
–
Surge voltage category / contamination class
–/–
Rated voltage
[V]
Rated surge voltage
[kV]
Nominal current / cross section
[A]/[mm2]
Maximum load current / cross section
[A]/[mm2]
Connection capacity
Solid / stranded / conductor sizes
[mm2]/[mm2]/AWG
Stranded with ferrule without / with plastic sleeve
[mm2]
Multiple connection (2 conductors with same cross section)
Solid / stranded
[mm2]
Stranded with ferrule without plastic sleeve
[mm2]
Stranded with TWIN ferrule with plastic sleeve
[mm2]
Stripping length
[mm]
Internal cylindrical gauge (IEC 60 947-1)
–
Thread
–
Torque
[Nm]
Insulating material
Inflammability class in acc. with UL 94
Approval data (UL/CUL and CSA)
Nominal voltage / current / conductor sizes
UL/CUL: [V]/[A]/AWG
CSA: [V]/[A]/AWG
1) When conductors with cross sections over 4 mm2 are connected,
appropriate measures must be taken in order to protect the soldered
connection and the PCB against mechanical stresses caused by
connected conductors.
in
ec
II / 2
630
4
on
l
0.5 - 61) / 0.5 - 4 / 20- 10
0.5 - 2.5 / 0.5 - 2.5
0.5 - 1.5 / 0.5 - 1.5
0.25 - 0.752)
0.5 - 1.52)
6.5
A3/B3
M3
0.5
PA
V0
300 / 20 / 20 - 12
––
2) When using ferrules, 250 V can only be achieved in connection with
surge voltage category / contamination class II / 2.
a
a + 5
1 3 ,5
5
4 ,1
6 ,2 8
9
2 ,5
I
III / 2
320
4
24 / 2.5
32 / 4.0
III / 3
250
4
6 ,2 8
2 ,5
5
a
1 ,3
PHOENIX CONTACT page 3 of 5
Printed Circuit
Screw Termination Blocks
PT 2,5/…-7,5-H
7.5 mm Pitch
Type
7.5
15
22.5
PT 2,5/2-7,5-H
PT 2,5/3-7,5-H
PT 2,5/4-7,5-H
5
6
7
30
37.5
45
PT 2,5/5-7,5-H
PT 2,5/6-7,5-H
PT 2,5/7-7,5-H
8
9
10
52.5
60
67.5
PT 2,5/8-7,5-H
PT 2,5/9-7,5-H
PT 2,5/10-7,5-H
11
12
75
82.5
PT 2,5/11-7,5-H
PT 2,5/12-7,5-H
Technical data
250
250
250
1988134
1988147
1988150
100
100
100
1988163
1988176
1988189
100
100
100
1988192
1988202
50
50
12 05 05 3
12 05 15 0
10
10
om
I
III / 2
800
6
24 / 2.5
32 / 4.0
in
ec
III / 3
500
6
II / 2
1000
6
0.5 - 61) / 0.5 - 4 / 20- 10
0.5 - 2.5 / 0.5 - 2.5
on
l
0.5 - 1.5 / 0.5 - 1.5
0.25 - 0.752)
0.5 - 1.52)
6.5
A3/B3
M3
0.5
PA
V0
––
––
) When using ferrules, 500 V can only be achieved in connection with
surge voltage category / contamination class II / 2.
2
9
a
a + 7 ,5
7 ,5
4 ,1
4 ,5
1 3 ,5
3 ,7 5
1988105
1988118
1988121
see description
7.5
1.3
∅ 1.0
po
Dimensions
Pitch
[mm]
Hole diameter
[mm]
Pin dimensions
[mm]x[mm]
Technical data in accordance with IEC/ DIN VDE
Insulating material group
–
Surge voltage category / contamination class
–/–
Rated voltage
[V]
Rated surge voltage
[kV]
Nominal current / cross section
[A]/[mm2]
Maximum load current / cross section
[A]/[mm2]
Connection capacity
Solid / stranded / conductor sizes
[mm2]/[mm2]/AWG
Stranded with ferrule without / with plastic sleeve
[mm2]
Multiple connection (2 conductors with same cross section)
Solid / stranded
[mm2]
Stranded with ferrule without plastic sleeve
[mm2]
Stranded with TWIN ferrule with plastic sleeve
[mm2]
Stripping length
[mm]
Internal cylindrical gauge (IEC 60 947-1)
–
Thread
–
Torque
[Nm]
Insulating material
Inflammability class in acc. with UL 94
Approval data (UL/CUL and CSA)
Nominal voltage / current / conductor sizes
UL/CUL: [V]/[A]/AWG
CSA: [V]/[A]/AWG
1
) When conductors with cross sections over 4 mm2 are connected,
appropriate measures must be taken in order to protect the soldered
connection and the PCB against mechanical stresses caused by
connected conductors.
Pcs./Pkt.
s.
SZS 0,6 x 3,5
SZK PH 1
ne
(1) Screwdriver
Order No.
m
2
3
4
nt
Printed circuit screw termination blocks with
housing interlocking, 7.5 mm pitch, color: green,
connection direction horizontal to the PCB
Dim.
a
[mm]
co
No. of pos.
Description
4 ,5
3 ,7 5
7 ,5
a
1 ,3
PHOENIX CONTACT page 4 of 5
Printed Circuit
Screw Termination Blocks
PT 2,5/…-7,5-V
7.5 mm Pitch
Type
7.5
15
22.5
PT 2,5/2-7,5-V
PT 2,5/3-7,5-V
PT 2,5/4-7,5-V
5
6
7
30
37.5
45
PT 2,5/5-7,5-V
PT 2,5/6-7,5-V
PT 2,5/7-7,5-V
8
9
10
52.5
60
67.5
PT 2,5/8-7,5-V
PT 2,5/9-7,5-V
PT 2,5/10-7,5-V
11
12
75
82.5
PT 2,5/11-7,5-V
PT 2,5/12-7,5-V
100
100
100
1988011
1988024
1988037
1988040
1988053
100
100
100
12 05 05 3
12 05 15 0
10
10
50
50
om
in
ec
II / 2
1000
6
0.5 - 61) / 0.5 - 4 / 20- 10
0.5 - 2.5 / 0.5 - 2.5
on
l
0.5 - 1.5 / 0.5 - 1.5
0.25 - 0.752)
0.5 - 1.52)
6.5
A3/B3
M3
0.5
PA
V0
––
––
) When using ferrules, 500 V can only be achieved in connection with
surge voltage category / contamination class II / 2.
2
7 ,5
a + 7 ,5
1 3 ,5
4 ,1
9
6 ,2 8
1987986
1987999
1988008
I
III / 2
800
6
24 / 2.5
32 / 4.0
III / 3
500
6
a
3 ,7 5
250
250
250
see description
7.5
1.3
∅ 1.0
po
Dimensions
Pitch
[mm]
Hole diameter
[mm]
Pin dimensions
[mm]x[mm]
Technical data in accordance with IEC/ DIN VDE
Insulating material group
–
Surge voltage category / contamination class
–/–
Rated voltage
[V]
Rated surge voltage
[kV]
Nominal current / cross section
[A]/[mm2]
Maximum load current / cross section
[A]/[mm2]
Connection capacity
Solid / stranded / conductor sizes
[mm2]/[mm2]/AWG
Stranded with ferrule without / with plastic sleeve
[mm2]
Multiple connection (2 conductors with same cross section)
Solid / stranded
[mm2]
Stranded with ferrule without plastic sleeve
[mm2]
Stranded with TWIN ferrule with plastic sleeve
[mm2]
Stripping length
[mm]
Internal cylindrical gauge (IEC 60 947-1)
–
Thread
–
Torque
[Nm]
Insulating material
Inflammability class in acc. with UL 94
Approval data (UL/CUL and CSA)
Nominal voltage / current / conductor sizes
UL/CUL: [V]/[A]/AWG
CSA: [V]/[A]/AWG
1
) When conductors with cross sections over 4 mm2 are connected,
appropriate measures must be taken in order to protect the soldered
connection and the PCB against mechanical stresses caused by
connected conductors.
1987957
1987960
1987973
6 ,2 8
3 ,7 5
7 ,5
a
1 ,3
PHOENIX
Phoenix
CONTACT
Contact page 5 of 5
TNR: 5127425-03/30.0.04.05 Phoenix Contact 2005
Technical data
Pcs./Pkt.
s.
SZS 0,6 x 3,5
SZK PH 1
ne
(1) Screwdriver
Order No.
m
2
3
4
nt
Printed circuit screw termination blocks with
housing interlocking, 7.5 mm pitch, color: green,
connection direction vertical to the PCB
Dim.
a
[mm]
co
No. of pos.
Description