0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2313478

2313478

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    SERIAL DEVICE SERVER 1-PORT

  • 数据手册
  • 价格&库存
2313478 数据手册
https://www.phoenixcontact.com/us/products/2313478 Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Second generation FL COMSERVER BASIC..., serial device server for converting a serial RS-232/422/485 interface to Ethernet, only supports TCP and UDP applications, incl. Com Port Redirector software and user documentation (PDF) Product Features ■ ■ ■ ■ ■ Reasonably-priced version Software for virtual COM ports supplied as standard TCP and UDP support Configuration via web-based management All connections can be plugged in using a COMBICON screw terminal block Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 200.0 g Custom tariff number 85176200 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 22.5 mm Height 99 mm Depth 116 mm Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C 03/14/2016   Page 1 / 8 https://www.phoenixcontact.com/us/products/2313478 Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478 Technical data Ambient conditions -20 °C ... 60 °C (With UL approval) Ambient temperature (storage/transport) -25 °C ... 70 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Altitude 5000 m (For restrictions see manufacturer's declaration) Degree of protection IP20 Noise immunity EN 61000-6-2:2005 General Electrical isolation DIN EN 50178 (VCC // Ethernet // Serial) Test voltage data interface/data interface 1.5 kVrms (50 Hz, 1 min.) Test voltage data interface/power supply 1.5 kVrms 1.5 kVrms (50 Hz, 1 min.) Standards/regulations EN 50121-4 Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) / 2014/30/EU (valid from 20.04.2016) Noise emission EN 61000-6-4 Net weight 180.3 g Housing material PA 6.6-FR Color green MTBF 666 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) 179 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) MTTF 2001 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day)) 870 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) 355 Years (SN 29500 standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day)) Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!) UL, USA Class I, Zone 2, AEx nA IIC T5 UL, USA / Canada 508 listed Class I, Div. 2, Groups A, B, C, D UL, Canada Class I, zone 2, Ex nA IIC T5 Gc X Power supply Nominal supply voltage 24 V AC/DC ±20 % (via pluggable COMBICON screw terminal block) 03/14/2016   Page 2 / 8 https://www.phoenixcontact.com/us/products/2313478 Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478 Technical data Power supply 24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply) Supply voltage range 19.2 V AC/DC ... 28.8 V AC/DC (via pluggable COMBICON screw terminal block) 22.8 V DC ... 25.2 V DC (as an alternative or redundant, via backplane bus contact and system current supply) Typical current consumption 100 mA (24 V DC) Serial interface Interface 1 Ethernet interface, 10/100BASE-T(X) in acc. with IEEE 802.3u Interface Ethernet Connection method RJ45 socket, shielded Transmission length ≤ 100 m (shielded twisted pair) Protocols supported TCP/IP, UDP Auxiliary protocols ARP, DHCP, BOOTP, SNMP, RIP, RARP, HTTP, TFTP Serial transmission speed 10/100 Mbps, auto negotiation Interface 2 V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1 Interface RS-232 Connection method D-SUB-9 plug File format/coding UART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity Transmission length 15 m Pin assignment DTE/DCE switchover via web-based management Data flow control/protocols Software handshake, Xon/Xoff or hardware handshake RTS/CTS Serial transmission speed 0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4 kbps Interface 3 RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1 Interface RS-422 Connection method Plug-in/screw connection via COMBICON File format/coding Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length Transmission length ≤ 1200 m Termination resistor 390 Ω (configurable) 180 Ω 390 Ω Data flow control/protocols Automatic control Serial transmission speed 0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4; 500; 1000 kbps Interface 4 RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire Interface RS-485 Connection method Plug-in/screw connection via COMBICON 03/14/2016   Page 3 / 8 https://www.phoenixcontact.com/us/products/2313478 Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478 Technical data Serial interface File format/coding UART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity Termination resistor 390 Ω (configurable) 180 Ω 390 Ω Data flow control/protocols Automatic control Serial transmission speed 0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4; 500; 1000 kbps Function Management Web-based management, SNMP, emergency exit with Telnet and serial Status and diagnostic indicators LEDs: UL (logic voltage), TD + RD (data activity serial), FD (full duplex), 100 (100 Mbps mode), Link (Ethernet), Activity (Ethernet), ERR (error) Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) / 2014/30/EU (valid from 20.04.2016) Type of test Free fall in acc. with IEC 60068-2-32 Test result 1m Type of test Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 Test result 5g, 10-150 Hz, 2.5 h, in XYZ direction Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Test result 15g, 11 ms period, half-sine shock pulse Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Test result 30g, 11 ms period, half-sine shock pulse Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2:2005 Free from substances that could impair the application of coating according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard Standards/regulations EN 50121-4 Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA Class I, Zone 2, AEx nA IIC T5 UL, USA / Canada 508 listed Class I, Div. 2, Groups A, B, C, D UL, Canada Class I, zone 2, Ex nA IIC T5 Gc X Classifications eCl@ss eCl@ss 4.0 27250504 03/14/2016   Page 4 / 8 https://www.phoenixcontact.com/us/products/2313478 Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478 Classifications eCl@ss eCl@ss 4.1 27250504 eCl@ss 5.0 27250504 eCl@ss 5.1 27250504 eCl@ss 6.0 27250504 eCl@ss 7.0 27250504 eCl@ss 8.0 19179290 ETIM ETIM 2.0 EC000310 ETIM 3.0 EC000310 ETIM 4.0 EC000310 ETIM 5.0 EC000310 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals Approvals UL Listed / cUL Listed / EAC / EAC / KC / cULus Listed Ex Approvals ATEX / ATEX / UL Listed / cUL Listed / cULus Listed Approvals submitted Approval details 03/14/2016   Page 5 / 8 https://www.phoenixcontact.com/us/products/2313478 Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478 Approvals UL Listed  cUL Listed  EAC  EAC  KC  cULus Listed  Drawings Connection diagram Connection diagram FL COMSERVER RS-485 FL COMSERVER RS-422 COMBICON D(A) D(B) + GND COMBICON Data A Data B GND D(B) D(A) T(B) T(A) GND + + - R(B) R(A) T(B) T(A) GND RS-485 connection RS-422 connection 03/14/2016   Page 6 / 8 https://www.phoenixcontact.com/us/products/2313478 Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478 Ethernet Comserver RS-485 Comserver Application drawing RS-485 Increasing the range with FL COMSERVER Application drawing UL TCP Header RS-232/RS-422/RS-485 Data TCP Header FD 100 FD 100 Data Serial Header Ethernet RS-232 Serial Header LAN / WLAN / GPRS / DSL / ISDN .... Ethernet UL TCP Header Data TCP Header RS-232/RS-422/RS-485 FD 100 FD RS-232 100 Serial Header Data Serial Header Serial data transmission via Ethernet 03/14/2016   Page 7 / 8 https://www.phoenixcontact.com/us/products/2313478 Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478 Application drawing UL RS-232/RS-422/RS-485 FD 100 FD 1 2 4 3 5 7 6 1 8 2 RS-232 100 9 4 3 5 6 7 8 Ethernet 9 Large value: "Idle Force Timeout Characters" Application drawing Ethernet UL RS-232/RS-422/RS-485 FD 100 FD 1 2 4 3 1 2 3 5 7 6 1 4 2 5 3 6 8 RS-232 100 9 1 7 2 8 3 9 Small value: "Idle Force Timeout Characters" Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 03/14/2016   Page 8 / 8
2313478 价格&库存

很抱歉,暂时无法提供与“2313478”相匹配的价格&库存,您可以联系我们找货

免费人工找货