https://www.phoenixcontact.com/us/products/2313478
Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Second generation FL COMSERVER BASIC..., serial device server for converting a serial RS-232/422/485
interface to Ethernet, only supports TCP and UDP applications, incl. Com Port Redirector software and user
documentation (PDF)
Product Features
■
■
■
■
■
Reasonably-priced version
Software for virtual COM ports supplied as standard
TCP and UDP support
Configuration via web-based management
All connections can be plugged in using a COMBICON screw terminal block
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
200.0 g
Custom tariff number
85176200
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
22.5 mm
Height
99 mm
Depth
116 mm
Ambient conditions
Ambient temperature (operation)
-25 °C ... 60 °C
03/14/2016 Page 1 / 8
https://www.phoenixcontact.com/us/products/2313478
Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478
Technical data
Ambient conditions
-20 °C ... 60 °C (With UL approval)
Ambient temperature (storage/transport)
-25 °C ... 70 °C
Permissible humidity (operation)
10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
5 % ... 95 % (non-condensing)
Altitude
5000 m (For restrictions see manufacturer's declaration)
Degree of protection
IP20
Noise immunity
EN 61000-6-2:2005
General
Electrical isolation
DIN EN 50178 (VCC // Ethernet // Serial)
Test voltage data interface/data interface
1.5 kVrms (50 Hz, 1 min.)
Test voltage data interface/power supply
1.5 kVrms
1.5 kVrms (50 Hz, 1 min.)
Standards/regulations
EN 50121-4
Electromagnetic compatibility
Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) /
2014/30/EU (valid from 20.04.2016)
Noise emission
EN 61000-6-4
Net weight
180.3 g
Housing material
PA 6.6-FR
Color
green
MTBF
666 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5
days a week, 8 hours a day))
179 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle
(5 days a week, 12 hours a day))
MTTF
2001 Years (SN 29500 standard, temperature 25°C, operating cycle 21 %
(5 days a week, 8 hours a day))
870 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25
% (5 days a week, 12 hours a day))
355 Years (SN 29500 standard, temperature 40°C, operating cycle 100 %
(7 days a week, 24 hours a day))
Conformance
CE-compliant
ATEX
II 3 G Ex nA IIC T4 Gc X (Please follow the special installation
instructions in the documentation!)
UL, USA
Class I, Zone 2, AEx nA IIC T5
UL, USA / Canada
508 listed
Class I, Div. 2, Groups A, B, C, D
UL, Canada
Class I, zone 2, Ex nA IIC T5 Gc X
Power supply
Nominal supply voltage
24 V AC/DC ±20 % (via pluggable COMBICON screw terminal block)
03/14/2016 Page 2 / 8
https://www.phoenixcontact.com/us/products/2313478
Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478
Technical data
Power supply
24 V DC ±5 % (as an alternative or redundant, via backplane bus contact
and system current supply)
Supply voltage range
19.2 V AC/DC ... 28.8 V AC/DC (via pluggable COMBICON screw terminal
block)
22.8 V DC ... 25.2 V DC (as an alternative or redundant, via backplane bus
contact and system current supply)
Typical current consumption
100 mA (24 V DC)
Serial interface
Interface 1
Ethernet interface, 10/100BASE-T(X) in acc. with IEEE 802.3u
Interface
Ethernet
Connection method
RJ45 socket, shielded
Transmission length
≤ 100 m (shielded twisted pair)
Protocols supported
TCP/IP, UDP
Auxiliary protocols
ARP, DHCP, BOOTP, SNMP, RIP, RARP, HTTP, TFTP
Serial transmission speed
10/100 Mbps, auto negotiation
Interface 2
V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
Interface
RS-232
Connection method
D-SUB-9 plug
File format/coding
UART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity
Transmission length
15 m
Pin assignment
DTE/DCE switchover via web-based management
Data flow control/protocols
Software handshake, Xon/Xoff or hardware handshake RTS/CTS
Serial transmission speed
0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4 kbps
Interface 3
RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Interface
RS-422
Connection method
Plug-in/screw connection via COMBICON
File format/coding
Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit
character length
Transmission length
≤ 1200 m
Termination resistor
390 Ω (configurable)
180 Ω
390 Ω
Data flow control/protocols
Automatic control
Serial transmission speed
0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4; 500;
1000 kbps
Interface 4
RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire
Interface
RS-485
Connection method
Plug-in/screw connection via COMBICON
03/14/2016 Page 3 / 8
https://www.phoenixcontact.com/us/products/2313478
Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478
Technical data
Serial interface
File format/coding
UART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity
Termination resistor
390 Ω (configurable)
180 Ω
390 Ω
Data flow control/protocols
Automatic control
Serial transmission speed
0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4; 500;
1000 kbps
Function
Management
Web-based management, SNMP, emergency exit with Telnet and serial
Status and diagnostic indicators
LEDs: UL (logic voltage), TD + RD (data activity serial), FD (full duplex),
100 (100 Mbps mode), Link (Ethernet), Activity (Ethernet), ERR (error)
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) /
2014/30/EU (valid from 20.04.2016)
Type of test
Free fall in acc. with IEC 60068-2-32
Test result
1m
Type of test
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result
5g, 10-150 Hz, 2.5 h, in XYZ direction
Type of test
Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result
15g, 11 ms period, half-sine shock pulse
Type of test
Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result
30g, 11 ms period, half-sine shock pulse
Noise emission
EN 61000-6-4
Noise immunity
EN 61000-6-2:2005
Free from substances that could impair the application of coating
according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Standards/regulations
EN 50121-4
Conformance
CE-compliant
ATEX
II 3 G Ex nA IIC T4 Gc X
UL, USA
Class I, Zone 2, AEx nA IIC T5
UL, USA / Canada
508 listed
Class I, Div. 2, Groups A, B, C, D
UL, Canada
Class I, zone 2, Ex nA IIC T5 Gc X
Classifications
eCl@ss
eCl@ss 4.0
27250504
03/14/2016 Page 4 / 8
https://www.phoenixcontact.com/us/products/2313478
Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478
Classifications
eCl@ss
eCl@ss 4.1
27250504
eCl@ss 5.0
27250504
eCl@ss 5.1
27250504
eCl@ss 6.0
27250504
eCl@ss 7.0
27250504
eCl@ss 8.0
19179290
ETIM
ETIM 2.0
EC000310
ETIM 3.0
EC000310
ETIM 4.0
EC000310
ETIM 5.0
EC000310
UNSPSC
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
39121008
Approvals
Approvals
Approvals
UL Listed / cUL Listed / EAC / EAC / KC / cULus Listed
Ex Approvals
ATEX / ATEX / UL Listed / cUL Listed / cULus Listed
Approvals submitted
Approval details
03/14/2016 Page 5 / 8
https://www.phoenixcontact.com/us/products/2313478
Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478
Approvals
UL Listed
cUL Listed
EAC
EAC
KC
cULus Listed
Drawings
Connection diagram
Connection diagram
FL COMSERVER RS-485
FL COMSERVER RS-422
COMBICON
D(A) D(B) +
GND
COMBICON
Data A
Data B
GND
D(B)
D(A)
T(B)
T(A)
GND
+
+
-
R(B)
R(A)
T(B)
T(A)
GND
RS-485 connection
RS-422 connection
03/14/2016 Page 6 / 8
https://www.phoenixcontact.com/us/products/2313478
Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478
Ethernet
Comserver
RS-485
Comserver
Application drawing
RS-485
Increasing the range with FL COMSERVER
Application drawing
UL
TCP
Header
RS-232/RS-422/RS-485
Data
TCP
Header
FD
100
FD
100
Data
Serial
Header
Ethernet
RS-232
Serial
Header
LAN / WLAN / GPRS / DSL / ISDN
....
Ethernet
UL
TCP
Header
Data
TCP
Header
RS-232/RS-422/RS-485
FD
100
FD
RS-232
100
Serial
Header
Data
Serial
Header
Serial data transmission via Ethernet
03/14/2016 Page 7 / 8
https://www.phoenixcontact.com/us/products/2313478
Interface converters - FL COMSERVER BASIC 232/422/485 - 2313478
Application drawing
UL
RS-232/RS-422/RS-485
FD
100
FD
1
2
4
3
5
7
6
1
8
2
RS-232
100
9
4
3
5
6
7
8
Ethernet
9
Large value: "Idle Force Timeout Characters"
Application drawing
Ethernet
UL
RS-232/RS-422/RS-485
FD
100
FD
1
2
4
3
1
2
3
5
7
6
1
4
2
5
3
6
8
RS-232
100
9
1
7
2
8
3
9
Small value: "Idle Force Timeout Characters"
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
03/14/2016 Page 8 / 8