SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 1 © PHOENIX CONTACT 2017-03-27 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12 Mbps. Under field conditions, it enables the quick and easy connection of the incoming and outgoing bus line. The product range includes ten fast connectors: Connection Cable entry Angled 35° Screw connection Angled 90° Axial Axial Push-in spring connection Angled 35° IDC connection Angled 90° Programming interface     Type Order No. SUBCON-PLUS-PROFIB/SC2 SUBCON-PLUS-PROFIB/PG/SC2 SUBCON-PLUS-PROFIB/90/SC SUBCON-PLUS-PROFIB/90/PG/SC SUBCON-PLUS-PROFIB/AX/SC SUBCON-PLUS-PROFIB/AX SUBCON-PLUS-PROFIB SUBCON-PLUS-PROFIB/PG SUBCON-PLUS-PROFIB/90/IDC SUBCON-PLUS-PROFIB/90/PG/IDC 2708232 2708245 2313698 2313708 2744380 2744377 2744348 2744403 2313672 2313685 WARNING: Explosion hazard when used in potentially explosive areas Connectors with screw connection or push-in spring connection: Follow the instructions provided here during installation and make sure you observe the safety notes. The connectors with IDC connection have no ATEX approval and are suitable only for safe areas. Make sure you always use the latest documentation. It can be downloaded at phoenixcontact.net/products. SUBCON-PLUS-PROFIB... Features – – – – – 2 All connectors can be used for PROFIBUS cables with a solid or stranded copper wire. All versions already have an integrated termination resistor. This is switched on externally via a slide switch. Concurrently, the outgoing bus segment is switched off. This makes it easy to start up segment by segment while incorrect terminations are avoided. In addition, the connector housing with high-quality shielding ensures a high level of immunity to interference even at maximum data transmission speed. The connectors are designed for all standard PROFIBUS cables with an outside diameter of 8 mm (types A and B). When using Fast Connect cables, work is reduced to a minimum by using the PSM-STRIPFC/PROFIB quick stripping tool. A special feature of the 35° angled connector is that the internal connection unit can be turned round. Whether the cable is to be inserted from the right or left can thus be decided on site. Table of contents 1 Description..................................................................................................................................1 2 Table of contents ........................................................................................................................2 3 Ordering data..............................................................................................................................3 4 Connectors with screw connection or push-in spring connection................................................5 4.1 4.2 4.3 4.4 4.5 4.6 Safety regulations and installation notes ........................................................................................................ 5 Installation in zone 2 ....................................................................................................................................... 5 SUBCON-PLUS-PROFIB(/PG)/SC2 .............................................................................................................. 6 SUBCON-PLUS-PROFIB/90(/PG)/SC ........................................................................................................... 9 SUBCON-PLUS-PROFIB/AX(/SC)............................................................................................................... 12 SUBCON-PLUS-PROFIB(/PG) .................................................................................................................... 15 5 Connectors with IDC connection...............................................................................................18 6 Termination resistor ..................................................................................................................20 101610_en_10 PHOENIX CONTACT 2 / 20 SUBCON-PLUS-PROFIB... 3 Ordering data Connectors with screw connection Type Order No. D-SUB 9 connector, pin, cable entry < 35°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8 D-SUB 9 connector, pin, cable entry < 35°, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8 D-SUB 9 connector, pin, cable entry < 90°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8 D-SUB 9 connector, pin, cable entry < 90°, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8 D-SUB 9 connector, pin, axial version with two cable entries, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8 SUBCON-PLUS-PROFIB/SC2 2708232 Pcs./ Pkt. 1 SUBCON-PLUS-PROFIB/PG/SC2 2708245 1 SUBCON-PLUS-PROFIB/90/SC 2313698 1 SUBCON-PLUS-PROFIB/90/PG/SC 2313708 1 SUBCON-PLUS-PROFIB/AX/SC 2744380 1 Plug with push-in spring connection Type Order No. D-SUB 9 connector, pin, axial version with two cable entries, SUBCON-PLUS-PROFIB/AX bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8 D-SUB 9 connector, pin, two cable entries < 35°, bus sysSUBCON-PLUS-PROFIB tem: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8 D-SUB 9 connector, pin, cable entry < 35°, bus system: SUBCON-PLUS-PROFIB/PG PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8 2744377 Pcs./ Pkt. 1 2744348 1 2744403 1 Connectors with IDC connection Type Order No. D-SUB 9 connector, pin, cable entry < 90°, bus system: PROFIBUS DP up to 12 Mbps, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8 D-SUB 9 connector, pin, cable entry < 90°, bus system: PROFIBUS DP up to 12 Mbps with PG D-SUB socket for connecting a programming device, termination resistor can be switched on via slide switch, pin assignment: 3, 5, 6, 8 SUBCON-PLUS-PROFIB/90/IDC 2313672 Pcs./ Pkt. 1 SUBCON-PLUS-PROFIB/90/PG/IDC 2313685 1 101610_en_10 PHOENIX CONTACT 3 / 20 SUBCON-PLUS-PROFIB... Accessories Type Order No. Quick stripping tool for PROFIBUS cable type Fast Connect Stripping pliers for PVC-insulated cables, stripping range: 0.08 to 6 mm², can cut wires up to 6 mm² stranded and 4 mm² solid PROFIBUS cable, Fast Connect type, up to 12 Mbps (02YSY (ST)CY 1x2x22 AWG) D-SUB connector, 9-pos., pin, assignment: 3, 5, 6, 8 Two M12 cable glands (B-coded) under 90° Bus system: PROFIBUS DP up to 12 Mbps Termination resistor via separate M12 terminator D-SUB connector, 9-pos., pin, assignment: 3, 5, 6, 8 Two M12 cable glands (B-coded) under 35° Bus system: PROFIBUS DP up to 12 Mbps Termination resistor via separate M12 terminator D-SUB connector, 9-pos., pin, assignment: 3, 5, 6, 8 Two M12 cable glands (B-coded) under 180° (axial) Bus system: PROFIBUS DP up to 12 Mbps Termination resistor via separate M12 terminator PSM-STRIP-FC/PROFIB QUICK WIREFOX 6 2744623 1204384 Pcs./ Pkt. 1 1 PSM-CABLE-PROFIB/FC 2744652 1 SUBCON-PLUS-PROFIB/90/M12 2902318 1 SUBCON-PLUS-PROFIB/35/M12 2902320 1 SUBCON-PLUS-PROFIB/AX/M12 2902321 1 101610_en_10 PHOENIX CONTACT 4 / 20 SUBCON-PLUS-PROFIB... 4 Connectors with screw connection or push-in spring connection 4.1 Safety regulations and installation notes 4.2 WARNING: Explosion hazard when used in potentially explosive areas WARNING: Observe the following safety notes when using the connector. • • • • • • The category 3 device is designed for installation in zone 2 potentially explosive areas. It meets the requirements of EN 60079-0:2012+A11:2013 and EN 6007915:2010. Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installation instructions as described. When installing and operating the device, the applicable regulations and safety directives (including national safety directives) as well as general technical regulations must be observed. The data on safety technology is provided in this packing slip and on the certificates (conformity assessment, additional approvals where applicable). Do not repair the device yourself; replace it with an equivalent device instead. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for damage resulting from non-compliance. The IP20 degree of protection (IEC 60529/EN 60529) of the device is intended for a clean and dry environment. Do not subject the device to mechanical and/or thermal loads that exceed the specified limits. The device is not designed for installation in zone 22. If, however, you wish to use the device in zone 22, it must be installed in a housing that complies with IEC/EN 60079-31. In doing so, observe the maximum surface temperatures. Observe the requirements of IEC/EN 60079-14. Make sure that the following notes and instructions are observed. WARNING: Explosion hazard when used in potentially explosive areas D-SUB interfaces may only be connected or disconnected when the voltage is disconnected. Screw the D-SUB mounting screws tight on all connectors. • • • • • • • • 101610_en_10 Installation in zone 2 Observe the specified conditions for use in potentially explosive areas. The device should be installed so that a degree of protection of at least IP54 is achieved in accordance with EN 60529. To this end, a suitable, approved housing that meets the requirements of EN 60079-15 should be used. Only devices which are designed for operation in Ex zone 2 and are suitable for the conditions at the installation location may be connected to the circuits in zone 2. In potentially explosive areas, only connect and disconnect cables when the power is disconnected. The switches of the device that can be accessed may only be actuated when the power supply to the device is disconnected. Connection to the D-SUB interface is only permitted if the screw connection is fully tightened. Temporary malfunctions (transients) must not exceed the rated voltage by more than 40%. The device must be stopped and immediately removed from the Ex area if it is damaged, was subjected to an impermissible load, stored incorrectly or if it malfunctions. PHOENIX CONTACT 5 / 20 SUBCON-PLUS-PROFIB... 4.3 SUBCON-PLUS-PROFIB(/PG)/SC2 SUBCON-PLUS-PROFIB/SC2 SUBCON-PLUS-PROFIB/PG/SC2 Connection Connector connection Programming connection 2708232 2708245 Interface connection Cable entry Connection cross section of screw terminal blocks 9-pos. D-SUB pin strip 9-pos. D-SUB socket strip (only for SUBCON-PLUS-PROFIB/PG/SC2) Screw connection Either left or right 0.14 mm2 ... 1.5 mm2 (26-16 AWG) Solid 0.14 mm2 ... 1 mm2 (26-18 AWG) >200 8 mm (± 0.4 mm) 4-40 UNC 0.4 Nm 3, 5, 6, 8 Stranded Insertion cycles Cable diameter Mounting screws Maximum tightening torque Pin assignment General data Degree of protection Housing material Nominal current IN Max. operating voltage Termination resistor Ambient conditions Temperature range IP40 ABS, metal-plated 100 mA 5V 390 Ω - 220 Ω - 390 Ω (switchable) Operation -20°C ... +75°C Storage/transport Relative humidity Approvals UL approval ATEX Please follow the special installation instructions in the documentation. Circuit diagram -25°C ... +80°C 75% at 25°C u file no. 238705  II 3 G Ex nA IIC T4 Gc X Dimensions 35,5 6 VP 5 GND 1B 3 D(P) 1A 8 D(N) 220Ω 390Ω 390Ω 16,6 2A OFF ON 39,4 2B S1 35 58 Figure 1 101610_en_10 Circuit diagram Figure 2 Dimensions PHOENIX CONTACT 6 / 20 SUBCON-PLUS-PROFIB... Structure Connection 9 1 5 18 2 8 24 3 4 5 7 6 Figure 3 1 2 3 4 5 6 7 8 9 Structure Upper housing part Slide switch Connection block for incoming bus Connection block for outgoing bus D-SUB mounting screws Lower housing part Strain relief PG connection (only for SUBCON-PLUS-PROFIB/PG/SC2) Housing screws 101610_en_10 Figure 4 Stripping The following stripping tools are recommended: – PSM-STRIP-FC/PROFIB, Order No. 2744623 – QUICK WIREFOX 6, Order No. 1204384 NOTE: Malfunction Observe the specified stripping lengths. PHOENIX CONTACT 7 / 20 SUBCON-PLUS-PROFIB... Right-hand side cable entry A WARNING: Explosion hazard when used in potentially explosive areas C D-SUB interfaces may only be connected or disconnected when the voltage is disconnected. Screw the D-SUB mounting screws tight on all connectors. B Cable entry can be from the right or left side. The connector supplied is pre-assembled for left-hand side entry. Left-hand side cable entry B C Figure 5 • • • • • • Left-hand side cable entry Strip off the conductors (see Figure 4). Loosen the housing screw. Lift off the top cover. Screw the stripped conductors into the corresponding connection block contacts. Always connect the incoming bus line to terminal block connections 1A/1B (even at the start of the bus system). Connect the outgoing bus line to terminal block connections 2A/2B. Observe the printing on the connection terminal blocks. Finally, close and screw tight the housing half shells. This creates the shield connection and strain relief for the bus line. A Figure 6 • • • • • • • • 101610_en_10 Right-hand side cable entry Strip off the conductors (see Figure 4). Loosen the housing screw. Lift off the top cover. Lever the PCB out of the lower housing part near the cable entry. Use a screwdriver to do this. Insert the PCB in the upper housing part. Screw the stripped conductors into the corresponding connection block contacts. Always connect the incoming bus line to terminal block connections 1A/1B (even at the start of the bus system). Connect the outgoing bus line to terminal block connections 2A/2B. Observe the printing on the connection terminal blocks. Finally, close and screw tight the housing half shells. This creates the shield connection and strain relief for the bus line. PHOENIX CONTACT 8 / 20 SUBCON-PLUS-PROFIB... 4.4 SUBCON-PLUS-PROFIB/90(/PG)/SC SUBCON-PLUS-PROFIB/90/SC SUBCON-PLUS-PROFIB/90/PG/SC Connection Connector connection Programming connection Interface connection Cable entry Connection cross section of screw terminal blocks 2313698 2313708 9-pos. D-SUB pin strip 9-pos. D-SUB socket strip (only for SUBCON-PLUS-PROFIB/90/PG/SC) Screw connection 90° angled cable outlet 0.14 mm2 ... 1.5 mm2 (26-16 AWG) Solid Stranded Insertion cycles Reconnection frequency Cable diameter Mounting screws Maximum tightening torque Pin assignment General data Degree of protection Housing material Nominal current IN Max. operating voltage Termination resistor Ambient conditions Temperature range Operation Storage/transport Relative humidity Approvals UL approval ATEX Please follow the special installation instructions in the documentation. 0.14 mm2 ... 1 mm2 (26-18 AWG) >200 5 8 mm (±0.4 mm) 4-40 UNC 0.4 Nm 3, 5, 6, 8 IP40 ABS, metal-plated 100 mA 5 V AC/DC 390 Ω - 220 Ω - 390 Ω (switchable) -20°C ... +75°C -25°C ... +80°C 75% at 25°C u file no. E238705  II 3 G Ex nA IIC T4 Gc X All common Fast Connect PROFIBUS cables with solid and stranded single wires are supported, e.g., PSM-CABLE-PROFIB/FC (Order No. 2744652). 101610_en_10 PHOENIX CONTACT 9 / 20 SUBCON-PLUS-PROFIB... Circuit diagram Structure 6 VP 5 GND 1B 3 D(P) 1A 8 D(N) 220Ω 390Ω 390Ω 2B 2A OFF ON S1 1 Figure 7 2 Circuit diagram Dimensions 72 16,6 35,5 SUBCON PLUS 35 Figure 8 101610_en_10 Dimensions 3 30 39,6 1A 1B 2A 2B 5 4 Figure 9 1 2 3 4 5 Structure Slide switch PG connection (only for SUBCON-PLUS-PROFIB/90/PG/SC) D-SUB mounting screws Terminal cover Strain relief PHOENIX CONTACT 10 / 20 SUBCON-PLUS-PROFIB... Connection 5 14 20 1 Figure 10 Stripping The following stripping tools are recommended: – PSM-STRIP-FC/PROFIB, Order No. 2744623 – QUICK WIREFOX 6, Order No. 1204384 NOTE: Malfunction 5 Figure 11 Observe the specified stripping lengths. • • • WARNING: Explosion hazard when used in potentially explosive areas • D-SUB interfaces may only be connected or disconnected when the voltage is disconnected. Screw the D-SUB mounting screws tight on all connectors. • • The connector allows the incoming and outgoing bus lines to be quickly connected. The connector contacts are routed onto screw terminal blocks with colored labeling. 2 4 3 Connecting Strip off the conductors (see Figure 10). Remove the separating foil if necessary. Insert the single wires into the connection terminal blocks as far as they will go. Always connect the incoming bus line to terminal block connections 1A/1B (even at the start of the bus system). Connect the outgoing bus line to terminal block connections 2A/2B. Observe the printing on the connection terminal blocks. Finally, mount and screw tight the connection terminal blocks. This creates the shield connection and strain relief for the bus line. The integrated termination resistor can be switched and, when activated, concurrently switches off the outgoing bus line. In this way, the bus system can be started up segment by segment. The strain relief is integrated in the housing half-shells. It is designed for standard PROFIBUS cable type A. The additionally integrated SUBCON-PLUS-PROFIB/90/PG/SC programming connection allows a programming or service device to be connected without interrupting the bus operation. 101610_en_10 PHOENIX CONTACT 11 / 20 SUBCON-PLUS-PROFIB... 4.5 SUBCON-PLUS-PROFIB/AX(/SC) Connection Connection cross section Solid SUBCON-PLUS-PROFIB/AX/SC 2744380 Screw connection SUBCON-PLUS-PROFIB/AX 2744377 Push-in spring connection 0.14 mm2 ... 1.5 mm2 (26-16 AWG) 0.12 mm2 ... 0.5 mm2 (26-20 AWG) 0.14 mm2 ... 1 mm2 (26-18 AWG) 9-pos. D-SUB pin strip Axial >200 8 mm (± 0.4 mm) 4-40 UNC 0.4 Nm 3, 5, 6, 8 Stranded Connector connection Cable entry Insertion cycles Cable diameter Mounting screws Maximum tightening torque Pin assignment General data Degree of protection Housing material Nominal current IN Max. operating voltage Termination resistor Ambient conditions Temperature range IP40 ABS, metal-plated 100 mA 5V 390 Ω - 220 Ω - 390 Ω (switchable) Operation -20°C ... +75°C Storage/transport Relative humidity Approvals UL approval ATEX Please follow the special installation instructions in the documentation. -25°C ... +80°C 75% at 25°C u file no. E238705  II 3 G Ex nA IIC T4 Gc X Circuit diagram Dimensions 20 6 VP 5 GND 1B 3 D(P) 1A 8 D(N) 220Ω 390Ω 390Ω 17 2B Figure 12 OFF ON S1 58,2 2A ON OFF Circuit diagram 31,5 Figure 13 101610_en_10 Dimensions PHOENIX CONTACT 12 / 20 SUBCON-PLUS-PROFIB... Structure SUBCON-PLUS-PROFIB/AX/SC with screw connection SUBCON-PLUS-PROFIB/AX with push-in spring connection 2 2 4 4 3 2 Figure 14 3 1 2 5 Structure Figure 15 1 2 3 4 5 Slide switch Housing Connection block Strain relief D-SUB mounting screw 101610_en_10 1 2 3 4 5 1 5 Structure Slide switch Housing Connection block with release rocker Strain relief D-SUB mounting screw PHOENIX CONTACT 13 / 20 SUBCON-PLUS-PROFIB... Connection WARNING: Explosion hazard when used in potentially explosive areas D-SUB interfaces may only be connected or disconnected when the voltage is disconnected. Screw the D-SUB mounting screws tight on all connectors. Figure 16 Stripping Figure 19 5 Connecting SUBCON-PLUS-PROFIB/AX/SC with screw connection 18 24 Figure 17 SUBCON-PLUS-PROFIB/AX/SC with screw connection • • • • • 9 18 Strip off the conductors (see Figure 17). Loosen the housing screw. Lift off the top cover. Screw the stripped conductors into the corresponding connection block contacts. Always connect the incoming bus line to terminal block connections 1A/1B (even at the start of the bus system). Connect the outgoing bus line to terminal block connections 2A/2B. Observe the printing on the connection terminal blocks. 24 Figure 18 SUBCON-PLUS-PROFIB/AX with push-in spring connection The following stripping tools are recommended: – PSM-STRIP-FC/PROFIB, Order No. 2744623 – QUICK WIREFOX 6, Order No. 1204384 SUBCON-PLUS-PROFIB/AX with push-in spring connection • • • NOTE: Malfunction Observe the specified stripping lengths. • • 101610_en_10 Strip off the conductors (see Figure 18). Loosen the housing screw. Lift off the top cover. Insert the single wires into the connection terminal blocks as far as they will go. The conductors automatically make contact when inserted. To release the connection, press the orange release rocker. Always connect the incoming bus line to terminal block connections 1A/1B (even at the start of the bus system). Connect the outgoing bus line to terminal block connections 2A/2B. Observe the printing on the connection terminal blocks. PHOENIX CONTACT 14 / 20 SUBCON-PLUS-PROFIB... 4.6 SUBCON-PLUS-PROFIB(/PG) SUBCON-PLUS-PROFIB SUBCON-PLUS-PROFIB/PG Connection Connector connection Programming connection 2744348 2744403 9-pos. D-SUB pin strip 9-pos. D-SUB socket strip (only for SUBCON-PLUS-PROFIB/PG) 35° Push-in spring connection 0.12 mm2 ... 0.5 mm2 (26-20 AWG) 5 mm >200 8 mm (± 0.4 mm) 4-40 UNC 0.4 Nm 3, 5, 6, 8 Cable entry Interface connection Connection cross-section: solid Stripping length Insertion cycles Cable diameter Mounting screws Maximum tightening torque Pin assignment General data Degree of protection Housing material Nominal current IN Max. operating voltage Termination resistor Ambient conditions Temperature range IP40 ABS, metal-plated 100 mA 5V 390 Ω - 220 Ω - 390 Ω (switchable) -20°C ... +75°C Operation -25°C ... +80°C Storage/transport Approvals UL approval u file no. E238705 ATEX  II 3 G Ex nA IIC T4 Gc X Please follow the special installation instructions in the documentation. Circuit diagram Dimensions 16 60 6 VP 5 GND 1B 3 D(P) 1A 8 D(N) 220Ω 390Ω 390Ω S1 10 OFF ON 49,5* 2A 44,5 2B 35 Figure 20 101610_en_10 Circuit diagram Figure 21 Dimensions PHOENIX CONTACT 15 / 20 SUBCON-PLUS-PROFIB... Structure Connection 1 9 9 24 30 8 2 3 1A 7 1B 2A 2B 6 5 4 Figure 23 Figure 22 1 2 3 4 5 6 7 8 9 Upper housing part Connection block Release rocker Lower housing part D-SUB mounting screw Strain relief Slide switch PG connection (only for SUBCON-PLUS-PROFIB/PG) Housing screw 101610_en_10 Stripping Structure The following stripping tools are recommended: – PSM-STRIP-FC/PROFIB, Order No. 2744623 – QUICK WIREFOX 6, Order No. 1204384 NOTE: Malfunction Observe the specified stripping lengths. PHOENIX CONTACT 16 / 20 SUBCON-PLUS-PROFIB... Right-hand side cable entry WARNING: Explosion hazard when used in potentially explosive areas 2B D-SUB interfaces may only be connected or disconnected when the voltage is disconnected. Screw the D-SUB mounting screws tight on all connectors. 1A 1B 2A Cable entry The SUBCON-PLUS-PROFIB/PG with programming interface is designed for left-hand side cable entry. The cable entry is not reversible. For SUBCON-PLUS-PROFIB, the cable entry can be from the right or left side. The connector supplied is pre-assembled for left-hand side entry. Removing the connection block Figure 26 Reversing the connection block 2B Figure 25 2A 1B 1A 1A 1B 2A 2B Left-hand side cable entry 1A 1B 2A 2B • • • Figure 24 • • • • • • Left-hand side cable entry Strip off the conductors (see Figure 23). Loosen the housing screw. Lift off the top cover. Insert the single wires into the connection terminal blocks as far as they will go. The conductors automatically make contact when inserted. To release the connection, press the orange release rocker. Always connect the incoming bus line to terminal block connections 1A/1B (even at the start of the bus system). Connect the outgoing bus line to terminal block connections 2A/2B. Observe the printing on the connection terminal blocks. Finally, close and screw tight the housing half shells. This creates the shield connection and strain relief for the bus line. 101610_en_10 • • • • • Strip off the conductors (see Figure 23). Loosen the housing screw. Lift off the top cover. Lever the PCB out of the lower housing part near the rivets. Use a screwdriver to do this. Remove the connection block. Rotate it 180°. Insert the single wires into the connection terminal blocks as far as they will go. The conductors automatically make contact when inserted. To release the connection, press the orange release rocker. Always connect the incoming bus line to terminal block connections 1A/1B (even at the start of the bus system). Connect the outgoing bus line to terminal block connections 2A/2B. Observe the printing on the connection terminal blocks. Finally, close and screw tight the housing half shells. This creates the shield connection and strain relief for the bus line. PHOENIX CONTACT 17 / 20 SUBCON-PLUS-PROFIB... 5 Connectors with IDC connection The connectors with IDC connection have no ATEX approval and are suitable only for safe areas. • Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installation instructions as described. SUBCON-PLUS-PROFIB/90/IDC SUBCON-PLUS-PROFIB/90/PG/IDC Connection Connector connection Programming connection Interface connection Cable entry Connection cross section of IDC terminal blocks (single-wire) • Do not repair the device yourself; replace it with an equivalent device instead. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for damage resulting from non-compliance. 2313672 2313685 9-pos. D-SUB pin strip 9-pos. D-SUB socket strip (only for SUBCON-PLUS-PROFIB/90/PG/IDC) IDC fast connection (insulation displacement connection technology) 90° angled cable outlet 0.32 mm2 ... 1 mm2 (22-18 AWG) Solid Stranded Insertion cycles Cable diameter Mounting screws Maximum tightening torque Pin assignment General data Degree of protection Housing material Nominal current IN Nominal voltage UN Termination resistor Ambient conditions Temperature range Operation Storage/transport Relative humidity Approvals UL approval 0.32 mm2 ... 1 mm2 (22-18 AWG) >200 8 mm (±0.4 mm) 4-40 UNC 0.4 Nm 3, 5, 6, 8 IP40 ABS, metal-plated 100 mA 5 V AC/DC 390 Ω - 220 Ω - 390 Ω (switchable) -20°C ... +75°C -25°C ... +80°C 75% at 25°C u file no. E238705 All common Fast Connect PROFIBUS cables with solid and stranded single wires are supported, e.g., PSM-CABLE-PROFIB/FC (Order No. 2744652). 101610_en_10 PHOENIX CONTACT 18 / 20 SUBCON-PLUS-PROFIB... Circuit diagram Structure 220Ω 390Ω 390Ω 6 VP 5 GND 2B 2A OFF ON S1 1 3 D(P) 8 D(N) 1A 1B 1A 2 1B 2A 2B Figure 27 Circuit diagram 5 4 3 Dimensions 72 16,6 Figure 29 30 39,6 1A 1B 2A 2B 1 2 SUBCON PLUS 35 Figure 28 Dimensions Structure 35,5 3 4 5 Slide switch PG connection (only for SUBCON-PLUS-PROFIB/90/PG/IDC) D-SUB mounting screw Terminal cover Strain relief Connection 11 17 Figure 30 Stripping The following stripping tools are recommended: – PSM-STRIP-FC/PROFIB, Order No. 2744623 – QUICK WIREFOX 6, Order No. 1204384 NOTE: Malfunction Observe the specified stripping lengths. 101610_en_10 PHOENIX CONTACT 19 / 20 SUBCON-PLUS-PROFIB... The connector allows the incoming and outgoing bus lines to be quickly connected. The connector contacts are routed onto IDC terminal blocks with color labeling. The integrated termination resistor can be switched and, when activated, concurrently switches off the outgoing bus line. In this way, the bus system can be started up segment by segment. 6 Termination resistor Note about connectors with screw connection or push-in spring connection: WARNING: Explosion hazard when used in potentially explosive areas The switches of the device that can be accessed may only be actuated when the power supply to the device is disconnected. The strain relief is integrated in the housing half-shells. It is designed for standard PROFIBUS cable type A. The additionally integrated SUBCON-PLUS-PROFIB/90/PG/IDC programming connection allows a programming or service device to be connected without interrupting the bus operation. OFF OFF OFF ON Figure 32 1 2 • 1A 1B 2A 2B 5 4 3 OFF ON Termination resistor Use the slide switch to activate the termination resistors at the start and end points of the bus system. Concurrently, the connection terminal blocks (2A/2B) for the outgoing bus line are switched off. The termination resistor must be deactivated at all other nodes in the bus system. Length according to PROFIBUS specification Figure 31 • • • • • • Strip off the conductors (see Figure 30). Remove the separating foil if necessary. Insert the single wires into the connection terminal blocks as far as they will go. Always connect the incoming bus line to terminal block connections 1A/1B (even at the start of the bus system). Connect the outgoing bus line to terminal block connections 2A/2B. Observe the printing on the connection terminal blocks. Then close and screw on the terminal cover. This creates the shield connection and strain relief for the bus line. 101610_en_10 Transmission speed Segment length 9.6 kbps 19.2 kbps 45.45 kbps 93.75 kbps 187.5 kbps 500 kbps 1500 kbps 3000 kbps ... 12000 kbps 1200 m 1200 m 1200 m 1200 m 1200 m 400 m 200 m Permissible branch lengths per bus segment 32 x 3 m 32 x 3 m 32 x 3 m 32 x 3 m 32 x 2 m 32 x 1 m 32 x 0.3 m 100 m Not permitted Connecting PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com 20 / 20
2313685 价格&库存

很抱歉,暂时无法提供与“2313685”相匹配的价格&库存,您可以联系我们找货

免费人工找货