0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2320102

2320102

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    模块

  • 描述:

    CONVERTER DC/DC 24VDC

  • 数据手册
  • 价格&库存
2320102 数据手册
https://www.phoenixcontact.com/gb/products/2320102 DC/DC converters - QUINT-PS/24DC/24DC/20 - 2320102 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 24 V DC, output: 24 V DC/20 A Product Description QUINT DC/DC converter with maximum functionality DC/DC converters alter the voltage level, regenerate the voltage at the end of long cables or enable the creation of independent supply systems by means of electrical isolation. QUINT DC/DC converters magnetically and therefore quickly trip circuit breakers with six times the nominal current, for selective and therefore cost-effective system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical operating states before errors occur. Why buy this product  Reliable starting of difficult loads, thanks to the static POWER BOOST power reserve with up to 125% nominal current permanently  Preventive function monitoring indicates critical operating states before errors occur  Constant voltage: output voltage regenerated even at the end of long cables  Support conversion to various voltage levels  Electrical isolation: for setting up independent supply systems Key Commercial Data Packing unit 1 STK GTIN GTIN 4046356481892 Weight per Piece (excluding packing) 1,700.000 g Custom tariff number 85044030 Country of origin China Technical data Dimensions Width 82 mm Height 130 mm Depth 125 mm 12/23/2016   Page 1 / 10 https://www.phoenixcontact.com/gb/products/2320102 DC/DC converters - QUINT-PS/24DC/24DC/20 - 2320102 Technical data Dimensions Width with alternative assembly 122 mm Height with alternative assembly 130 mm Depth with alternative assembly 85 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C derating, 2.5 %/K, startup at -40°C type-tested) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Noise immunity EN 61000-6-2:2005 Input data Nominal input voltage range 24 V DC Input voltage range 18 V DC ... 32 V DC Current consumption 28 A (24 V, IBOOST) Inrush surge current < 26 A (typical) Power failure bypass > 10 ms (24 V DC) Choice of suitable circuit breakers 40 A ... 50 A (Characteristics B, C, D, K) Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 24 V DC ±1 % Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) Nominal output current (IN) 20 A (-25 °C ... 60 °C) POWER BOOST (IBoost) 25 A (-25°C ... 40°C permanent, UOUT = 24 V DC ) Selective Fuse Breaking (ISFB) 120 A (12 ms) Derating 60 °C ... 70 °C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series yes Max. capacitive load Unlimited Active current limitation Approximately 29 A Control deviation < 1 % (change in load, static 10 % ... 90 %) < 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %) Residual ripple < 20 mVPP Peak switching voltages nominal load < 10 mVPP (20 MHz) Maximum power dissipation in no-load condition 2.2 W Power loss nominal load max. 39 W General Net weight 1.7 kg Efficiency > 93 % 12/23/2016   Page 2 / 10 https://www.phoenixcontact.com/gb/products/2320102 DC/DC converters - QUINT-PS/24DC/24DC/20 - 2320102 Technical data General Insulation voltage input/output 1.5 kV (type test) 1 kV (routine test) Protection class III > 554000 h (40°C) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Alignable: 5 mm horizontally, 15 mm next to active components, 50 mm vertically Connection data, input Connection method Screw connection Conductor cross section solid min. 0.5 mm² Conductor cross section solid max. 16 mm² Conductor cross section flexible min. 0.5 mm² Conductor cross section flexible max. 16 mm² Conductor cross section AWG min. 8 Conductor cross section AWG max. 6 Stripping length 10 mm Screw thread M3 Connection data, output Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 6 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 4 mm² Conductor cross section AWG min. 12 Conductor cross section AWG max. 10 Stripping length 8 mm Screw thread M3 Connection data for signaling Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Screw thread M3 Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27) Noise immunity EN 61000-6-2:2005 12/23/2016   Page 3 / 10 https://www.phoenixcontact.com/gb/products/2320102 DC/DC converters - QUINT-PS/24DC/24DC/20 - 2320102 Technical data Standards and Regulations Connection in acc. with standard CUL Standards/regulations EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 Standard - Electrical safety EN 60950-1/VDE 0805 (SELV) Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard – Safety extra-low voltage EN 60950-1 (SELV) EN 60204 (PELV) Standard - Safe isolation DIN VDE 0100-410 Shipbuilding approval Germanischer Lloyd (EMC 1) UL approvals UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950 UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) 15 Hz ... 150 Hz, 2.3g, 90 min. Rail applications EN 50121-4 Drawings Block diagram + + - + - UIN>19,2 V DC OK I
2320102 价格&库存

很抱歉,暂时无法提供与“2320102”相匹配的价格&库存,您可以联系我们找货

免费人工找货