0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2320908

2320908

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 24V 120W

  • 数据手册
  • 价格&库存
2320908 数据手册
https://www.phoenixcontact.com/us/products/2320908 Power supply, with protective coating - QUINT-PS/1AC/24DC/ 5/ CO - 2320908 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, with protective coating, input: 1-phase, output: 24 V DC/5 A Product Description QUINT POWER power supplies with maximum functionality QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective system protection. In addition, the high system availability is ensured by preventive function monitoring which reports critical operating states before errors can occur. Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 18 V DC ... 29.5 V DC are covered. Product Features ■ ■ ■ ■ ■ For superior system availability Reliable starting of difficult loads with the static POWER BOOST power reserve with up to 1.5 times the nominal current permanently Fast tripping of standard circuit breakers with dynamic power reserve SFB (selective fuse breaking) technology with up to 6 times the nominal current for 12 ms Preventive function monitoring Optimum protection with dip coating for 100 % humidity Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 1020.0 g Custom tariff number 85044030 Country of origin Thailand Technical data Dimensions 04/28/2016   Page 1 / 7 https://www.phoenixcontact.com/us/products/2320908 Power supply, with protective coating - QUINT-PS/1AC/24DC/ 5/ CO - 2320908 Technical data Dimensions Width 40 mm Height 130 mm Depth 125 mm Width with alternative assembly 122 mm Height with alternative assembly 130 mm Depth with alternative assembly 43 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) 100 % (at 25 °C, non-condensing) Noise immunity EN 61000-6-2:2005 Maximum altitude 6000 m Input data Nominal input voltage range 100 V AC ... 240 V AC Input voltage range 85 V AC ... 264 V AC 90 V DC ... 410 V DC +5 % (UL 508: ≤ 250 V DC) Dielectric strength maximum 300 V AC AC frequency range 45 Hz ... 65 Hz Frequency range DC 0 Hz Discharge current to PE < 3.5 mA Current consumption 1.2 A (120 V AC) 0.6 A (230 V AC) 1.2 A (110 V DC) 0.6 A (220 V DC) Inrush surge current < 15 A (typical) Power failure bypass > 55 ms (120 V AC) > 55 ms (230 V AC) Input fuse 5 A (slow-blow, internal) Choice of suitable circuit breakers 6 A ... 16 A (AC: Characteristics B, C, D, K) Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 24 V DC ±1 % 04/28/2016   Page 2 / 7 https://www.phoenixcontact.com/us/products/2320908 Power supply, with protective coating - QUINT-PS/1AC/24DC/ 5/ CO - 2320908 Technical data Output data Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) Nominal output current (IN) 5 A (-25°C ... 60°C, UOUT = 24 V DC) POWER BOOST (IBoost) 7.5 A (UIn ≥ 100 V AC) Selective Fuse Breaking (ISFB) 30 A (12 ms) Derating 60 °C ... 70 °C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series Yes Control deviation < 1 % (change in load, static 10 % ... 90 %) < 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %) Residual ripple < 40 mVPP (with nominal values) Output power 120 W Typical response time < 0.15 s Maximum power dissipation in no-load condition 90 % (for 230 V AC and nominal values) Insulation voltage input/output 4 kV AC (type test) 2 kV AC (routine test) Protection class I MTBF (IEC 61709, SN 29500) > 1134000 h (25 °C) > 635000 h (40°C) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Alignable: 5 mm horizontally, 15 mm next to active components, 50 mm vertically Connection data, input Connection method Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 20 Conductor cross section AWG max. 12 Stripping length 7 mm 04/28/2016   Page 3 / 7 https://www.phoenixcontact.com/us/products/2320908 Power supply, with protective coating - QUINT-PS/1AC/24DC/ 5/ CO - 2320908 Technical data Connection data, input Screw thread M3 Connection data, output Connection method Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 20 Conductor cross section AWG max. 12 Stripping length 7 mm Screw thread M3 Connection data for signaling Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 20 Conductor cross section AWG max. 12 Screw thread M3 Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Shock 30g in each direction, according to IEC 60068-2-27 Noise emission EN 55011 (EN 55022) Noise immunity EN 61000-6-2:2005 Connection in acc. with standard CSA Standards/regulations EN 61000-4-3 EN 61000-4-4 EN 61000-4-6 Standard – Electrical equipment of machines EN 60204-1 Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV) Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV) Standard - Safe isolation DIN VDE 0100-410 04/28/2016   Page 4 / 7 https://www.phoenixcontact.com/us/products/2320908 Power supply, with protective coating - QUINT-PS/1AC/24DC/ 5/ CO - 2320908 Technical data Standards and Regulations Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178 Standard – Limitation of mains harmonic currents EN 61000-3-2 Standard - Equipment safety BG (design tested) Shipbuilding approval Germanischer Lloyd (EMC 2) UL approvals UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950 UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) DeviceNet approval DeviceNet™ Power Supply Conformance Tested Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) Low Voltage Directive Conformance with LV directive 2006/95/EC Approval - requirement of the semiconductor industry with regard to mains SEMI F47-0706 Compliance Certificate; EN 61000-4-11 voltage dips Information technology equipment - safety (CB scheme) IEC 60950 (2  Edition) Rail applications EN 50121-4 ATEX  II 3 G Ex nA nC IIC T4 Gc nd TÜV 11 ATEX 555674 X IECEx Ex nA nC IIC T4 Gc IECEx TUN 11.0002X Overvoltage category III Classifications eCl@ss eCl@ss 4.0 27040702 eCl@ss 4.1 27040702 eCl@ss 5.0 27049002 eCl@ss 5.1 27049002 eCl@ss 6.0 27049002 eCl@ss 7.0 27049002 eCl@ss 8.0 27049002 eCl@ss 9.0 27040701 ETIM ETIM 4.0 EC000599 ETIM 5.0 EC002540 04/28/2016   Page 5 / 7 https://www.phoenixcontact.com/us/products/2320908 Power supply, with protective coating - QUINT-PS/1AC/24DC/ 5/ CO - 2320908 Classifications UNSPSC UNSPSC 6.01 30211502 UNSPSC 7.0901 39121004 UNSPSC 11 39121004 UNSPSC 12.01 39121004 UNSPSC 13.2 39121004 Approvals Approvals Approvals CSA / UL Recognized / UL Listed / cUL Recognized / GL / IECEE CB Scheme / Bauartgeprüft / EAC / EAC / cULus Recognized Ex Approvals IECEx / ATEX / UL Listed / cUL Listed / cULus Listed Approvals submitted Approval details CSA  UL Recognized  UL Listed  cUL Recognized  04/28/2016   Page 6 / 7 https://www.phoenixcontact.com/us/products/2320908 Power supply, with protective coating - QUINT-PS/1AC/24DC/ 5/ CO - 2320908 Approvals GL  IECEE CB Scheme  Bauartgeprüft  EAC  EAC  cULus Recognized  Drawings Block diagram L (+) active N (-) PFC DC OK I < IN 13 14 Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 04/28/2016   Page 7 / 7
2320908 价格&库存

很抱歉,暂时无法提供与“2320908”相匹配的价格&库存,您可以联系我们找货

免费人工找货