0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2322786

2322786

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    CABLEASSEMBLYINTERFACE3.28'

  • 数据手册
  • 价格&库存
2322786 数据手册
https://www.phoenixcontact.com/us/products/2322786 Front adapters - FLK 40-PA/EZ-DR/KS/ 100/YUC - 2322786 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Cast front adapter with attached round cable and a 40-pos. socket strip injection-molded on both sides for the connection of Yokogawa controllers. Cable length: 1.0 m Your advantages  Molded connectors  Can be screwed on  KS/AKB-compatible connectors on the module side  Lateral cable outlet of the I/O module Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356451246 Weight per Piece (excluding packing) 279.300 g Custom tariff number 85444290 Country of origin Germany Technical data Note Type of note Notes on operation Note No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC). Ambient conditions Ambient temperature (operation) -40 °C ... 70 °C (fixed installation) -10 °C ... 70 °C (flexible installation) 06/06/2020   Page 1 / 8 https://www.phoenixcontact.com/us/products/2322786 Front adapters - FLK 40-PA/EZ-DR/KS/ 100/YUC - 2322786 Technical data Ambient conditions Ambient temperature (storage/transport) -40 °C ... 80 °C Maximum altitude ≤ 2000 m Degree of protection IP20 ≥ IP54 (Installation location) General Max. permissible operating voltage 30 V DC Max. permissible current 500 mA (per path) Nominal operating mode 100% operating factor Standards and Regulations Flame resistance UL VW-1 CSA FT-1 IEC 60332-1-2 VDE 0842, Part 332-1-2 IEC 60332-3-22 Resistance to oil against occasional splashes Gasoline resistance against occasional splashes Designation Air clearances and creepage distances Standards/regulations DIN EN 50178 Rated insulation voltage 63 V Rated surge voltage 0.6 kV Insulation Functional insulation Pollution degree 2 Overvoltage category II Connection data Connection name Control side Connection method Yokogawa, I/O cards compatible Number of connections 1 Number of positions 40 Torque 0.5 Nm (Screw connection) Insertion/withdrawal cycles > 50 Connection data 2 Connection name Field level Connection method Yokogawa, KS compatible Number of connections 1 Number of positions 40 06/06/2020   Page 2 / 8 https://www.phoenixcontact.com/us/products/2322786 Front adapters - FLK 40-PA/EZ-DR/KS/ 100/YUC - 2322786 Technical data Connection data 2 Torque 0.5 Nm (Screw connection) Insertion/withdrawal cycles > 50 Cable Conductor construction: Number of litz wires: 7 Single wire, material Cu tin-plated Single wire, cross section 0.14 mm² Length of cable 1m Outer sheath, material Semi-rigid PVC External sheath, color gray Shielding yes Halogen-free cable No Cable insulation resistance ≥ 20 MΩ/km (at 20 °C) Cable resistance ≤ 145 Ω/km (at 20 °C) Supported controller Controller YOKOGAWA CS3000 CentumVP - suitable I/O card AAI543 AAI141 AAI143 AAI835 AAI841 AAI135 AAR181 AAT141 AAV141 AAV142 AAB841 AAV542 Controller YOKOGAWA STARDOM - suitable I/O card NFAI543 NFAI141 NFAI143 NFAI835 NFAI841 NFAI135 NFAV141 NFAV142 06/06/2020   Page 3 / 8 https://www.phoenixcontact.com/us/products/2322786 Front adapters - FLK 40-PA/EZ-DR/KS/ 100/YUC - 2322786 Technical data Supported controller NFAB841 NFAV542 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 06/06/2020   Page 4 / 8 https://www.phoenixcontact.com/us/products/2322786 Front adapters - FLK 40-PA/EZ-DR/KS/ 100/YUC - 2322786 Connection diagram 06/06/2020   Page 5 / 8 https://www.phoenixcontact.com/us/products/2322786 Front adapters - FLK 40-PA/EZ-DR/KS/ 100/YUC - 2322786 Classifications eCl@ss eCl@ss 10.0.1 27242292 eCl@ss 4.0 27060300 eCl@ss 4.1 27060300 eCl@ss 5.0 27061800 eCl@ss 5.1 27061800 eCl@ss 6.0 27249200 eCl@ss 7.0 27249290 eCl@ss 8.0 27249290 eCl@ss 9.0 27242292 ETIM ETIM 4.0 EC002584 ETIM 5.0 EC002584 ETIM 6.0 EC002584 ETIM 7.0 EC002584 UNSPSC UNSPSC 6.01 26121620 UNSPSC 7.0901 26121620 UNSPSC 11 26121620 UNSPSC 12.01 26121620 UNSPSC 13.2 32151601 UNSPSC 18.0 32151601 UNSPSC 19.0 32151601 UNSPSC 20.0 32151601 UNSPSC 21.0 32151601 Approvals Approvals Approvals UL Listed / cUL Listed / EAC / cULus Listed Ex Approvals 06/06/2020   Page 6 / 8 https://www.phoenixcontact.com/us/products/2322786 Front adapters - FLK 40-PA/EZ-DR/KS/ 100/YUC - 2322786 Approvals Approval details UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm     Nominal voltage UN 125 V Nominal current IN 0.5 A cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm     Nominal voltage UN 125 V Nominal current IN 0.5 A EAC  cULus Listed   FILE E 238705  FILE E 238705     RU CDE.A*30.B00767      Accessories Accessories Marker carrier cable Cable marker carrier - KME - 0807083 Cable marker carrier, white, unlabeled, mounting type: Assembly with cable binders, cable diameter: > 5 mm, lettering field size: 20 mm x 8 mm     Spare parts 06/06/2020   Page 7 / 8 https://www.phoenixcontact.com/us/products/2322786 Front adapters - FLK 40-PA/EZ-DR/KS/ 100/YUC - 2322786 Accessories Screw set - VF-SCREW-YOKOGAWA/M3X18/DCS - 2902873 Replacement screw M3x18 for Yokogawa system cable, front adapter control side.     Screw set - VF-SCREW-YOKOGAWA/M4X25/KS - 2902874 Replacement screw M4x25 for Yokogawa system cable, module side.     Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 06/06/2020   Page 8 / 8
2322786 价格&库存

很抱歉,暂时无法提供与“2322786”相匹配的价格&库存,您可以联系我们找货

免费人工找货