AXC F XT ETH 1TX
Axioline F, left-alignable Ethernet interface
Data sheet
107237_en_01
1
© PHOENIX CONTACT 2019-03-04
Description
An AXC F ... PLCnext controller can be extended with an
additional Ethernet interface using the AXC F XT ETH 1TX
left-alignable extension module.
Features
–
–
–
–
–
Individual expansion option for PLCnext Controls of the
Axiocontrol series
Left-alignable Gigabit-class Ethernet interface
Additional independent MAC address
PROFINET support
Electrical isolation between Ethernet interface and logic
Ensure that the left-alignable Ethernet
interface is only aligned next to a PLCnext
controller which has a firmware version that is
permissible for this.
AXC F ... PLCnext controllers with the
following firmware versions are permitted:
– AXC F 2152 with firmware version
2019.0 LTS
This data sheet is only valid in association with the UM EN AXL F SYS INST user manual.
For information on PROFINET basics, please refer to the UM EN PROFINET SYS user manual.
Make sure you always use the latest documentation.
It can be downloaded at: phoenixcontact.net/product/2403115
AXC F XT ETH 1TX
2
Table of contents
1
Description .............................................................................................................................. 1
2
Table of contents ..................................................................................................................... 2
3
Ordering data .......................................................................................................................... 3
4
Technical data ......................................................................................................................... 4
5
Internal circuit diagram ............................................................................................................ 6
6
Module components ................................................................................................................ 6
7
Mounting.................................................................................................................................. 7
7.1
Removing the controller supply connector.................................................................................. 7
7.2
Removing other connectors from the controller ........................................................................... 7
7.3
Removing electronics modules ............................................................................................... 7
7.4
Snapping on electronics modules ............................................................................................ 8
7.5
Inserting supply connector ..................................................................................................... 8
8
Connecting the supply voltage and Ethernet ........................................................................... 9
8.1
Connecting the supply voltage ................................................................................................ 9
8.2
Connecting Ethernet ............................................................................................................. 9
9
Connection example.............................................................................................................. 10
10
Application example .............................................................................................................. 10
11
Diagnostics and status indicators .......................................................................................... 11
11.1 Diagnostics and status indicators of the left-alignable Ethernet interface.......................................... 11
11.2 Diagnostic indicators of the controller ..................................................................................... 12
107237_en_01
PHOENIX CONTACT
2 / 12
AXC F XT ETH 1TX
3
Ordering data
Description
Type
Order No.
Pcs./Pkt.
Left-alignable Ethernet interface, for connection to a
AXC F XT ETH 1TX
compatible modular controller from the Axiocontrol range.
2403115
1
Accessories
Type
Order No.
Pcs./Pkt.
PLCnext Control for the direct control of Axioline F I/Os.
With two Ethernet interfaces. Complete with connector
and bus base module.
AXC F 2152
2404267
1
Bus base for extension modules that can be aligned to the AXC BS H XT
left
2403678
5
Bus base module for left-aligning the AXC F 2xxx
controllers
AXC BS L 2
1064312
1
Axioline F short power connector (for e.g., AXL F BK ...)
(Replacement item)
AXL CN S/UL
2701421
5
Documentation
Type
Order No.
Pcs./Pkt.
User manual, English, Axioline F: System and installation UM EN AXL F SYS INST
-
-
User manual, English, Axioline F: Diagnostic registers,
and error messages
UM EN AXL F SYS DIAG
-
-
User manual, English, PROFINET basics
UM EN PROFINET SYS
-
-
107237_en_01
PHOENIX CONTACT
3 / 12
AXC F XT ETH 1TX
4
Technical data
Dimensions (nominal sizes in mm)
122,4
54
126,1
35
Width
35 mm
Height
126.1 mm
Depth
54 mm
Note on dimensions
The depth is valid when a TH 35-7,5 DIN rail is used (according
to EN 60715).
General data
Type
modular
Color
traffic grey A RAL 7042
Weight
106 g (with connector and bus base module)
Ambient temperature (operation)
-25 °C ... 60 °C (up to 2000 m above sea level)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
5 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)
5 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
58 kPa ... 106 kPa (up to 4500 m above mean sea level)
Degree of protection
IP20
Protection class
III, IEC 61140, EN 61140, VDE 0140-1
Mounting type
DIN rail mounting
Connection data: Axioline F connector
Connection method
Push-in connection
Conductor cross section solid / stranded
0.2 mm² ... 1.5 mm² / 0.2 mm² ... 1.5 mm²
Conductor cross section [AWG]
24 ... 16
Stripping length
8 mm
Interface Ethernet
Number of interfaces
1
Connection method
RJ45 socket
Note on the connection method
Auto negotiation and autocrossing
107237_en_01
PHOENIX CONTACT
4 / 12
AXC F XT ETH 1TX
Interface Ethernet
Bus system
RJ45
Transmission speed
10/100/1000 Mbps (full duplex)
Transmission length
max. 100 m
Interface Axioline F local bus
Number of interfaces
1
Connection method
Bus base module
Transmission speed
100 Mbps
Supply of the logic voltage UL
Supply voltage
24 V DC
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Polarity reversal protection of the supply voltage
Polarity protection diode
Transient protection
Suppressor diode
NOTE: Damage to the electronics
Provide external protection for the module.
Error messages to the higher level control or computer system
None
Mechanical tests
Vibration resistance in acc. with EN 60068-2-6/
IEC 60068-2-6
5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27
30g
Continuous shock according to EN 60068-2-27/
IEC 60068-2-27
10g
Conformance with EMC Directive 2014/30/EU
Noise immunity test in accordance with EN 61000-6-2
Electrostatic discharge (ESD) EN 61000-4-2/
IEC 61000-4-2
Criterion B, 6 kV contact discharge, 8 kV air discharge
Electromagnetic fields EN 61000-4-3/IEC 61000-4-3
Criterion A, Field intensity: 10 V/m
Fast transients (burst) EN 61000-4-4/IEC 61000-4-4
Criterion B, 2 kV
Transient overvoltage (surge) EN 61000-4-5/
IEC 61000-4-5
Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/
asymmetrical)
Conducted interference EN 61000-4-6/IEC 61000-4-6
Criterion A; Test voltage 10 V
Noise emission test according to EN 61000-6-3
Class B
Approvals
For the latest approvals, please visit phoenixcontact.net/products.
107237_en_01
PHOENIX CONTACT
5 / 12
AXC F XT ETH 1TX
5
Internal circuit diagram
Ethernet
6
Module components
Logic / FE
5
RJ45
6
LNK ACT
Chipset
UL
UL
VCC
4
Extension bus
1
24V
3
2
UL
24 V
Figure 1
Basic circuit diagram
Key:
RJ45
RJ45 interface
LED
Power supply unit with electrical isolation
Figure 2
1
2
3
4
5
6
Module components
Bus base module
Electronics module
Supply connector
Function identification
Diagnostic and status indicators
Ethernet interface
Power supply unit
XXX
XXX
Chipset
Extension bus
107237_en_01
Chipset
Axioline F extension modules aligned to
the left
PHOENIX CONTACT
6 / 12
AXC F XT ETH 1TX
7.3
Mounting
Before the left-alignable Ethernet interface can be aligned to
the controller, you must remove the controller electronics
module.
To do this, proceed as follows:
•
Insert a suitable tool (e.g., bladed screwdriver) into the
upper and lower snap-on mechanisms (base latches) of
the controller/module one after the other and release it
(A).
The base latches are locked in place in the open position.
•
Remove the electronics module vertically out of the DIN
rail (B).
A
A
X
X
.X
X
.X
X
.X
X
D
.X
R
A
C
4
r.:
X
O
rd
.N
o.
24
04
26
7
R
A
-C
A
dd
D
Release the locking latch (A), tilt the supply connector
upwards slightly (B), and remove it from the controller
(C).
.X
X
C
F
21
52
B
Removing the controller supply connector
S
1
X
2
X
X
2
X
1
A
X
X
r.:
o.
.N
rd
O
M
dd
A
A
7
26
04
24
C
A
X
X
X
.X
X
X
.X
21
F
C
X
.X
52
.X
.X
X
4
R
S
D
-C
A
R
D
•
In the case of AXC ... controllers, you must also remove the
electronics module of the first module aligned to the right.
X
Mount all the modules required before
supplying power to the Axioline F station.
Modules to which power is only supplied
following the controller boot process are not
detected or may result in a malfunction.
To ensure that the left-alignable Ethernet
interface is detected correctly, proceed as
follows:
– Switch on the power to the left-alignable
Ethernet interface before switching on the
power to the controller
OR
– Switch on the power to the left-alignable
Ethernet interface and to the controller
simultaneously.
X
Please note:
7.1
Removing electronics modules
M
7
Removing the electronics module
X
1
X
2
Figure 4
To operate the left-alignable Ethernet interface on a
controller for Axioline F, a special bus base module is
required for the respective controller.
The bus base module is not supplied as standard with
AXC ... controllers. For the ordering data, please refer to the
user manual for the controller you are using.
In the case of AXC ... controllers, you must first replace the
existing bus base module with the special bus base module.
Figure 3
7.2
•
Removing the supply connector
Removing other connectors from the controller
Remove all other connectors from the controller.
To do this, proceed as follows:
•
Remove the controller bus base module from the bus
base of the first module aligned to the right.
•
Remove the controller bus base module from the DIN
rail.
Proceed as follows to mount the special bus base module:
107237_en_01
PHOENIX CONTACT
7 / 12
AXC F XT ETH 1TX
•
C
D
•
A
B
7.4
•
7.5
Figure 5
•
•
•
•
Place the bus base modules of the additional
AXC F XT ... modules to be aligned on the left on the
DIN rail (B).
Push each subsequent bus base module into the
connection of the previous bus base module (C).
Snapping on electronics modules
Working from right to left, place each electronics
module vertically on the corresponding bus base
module and on the DIN rail until it snaps into place with
a click. Make sure that the device plug for the bus base
connection is situated above the corresponding socket
on the bus base module.
Inserting supply connector
A
Mount bus base module(s)
Place the special controller bus base module on the DIN
rail (A).
Push the special controller bus base module into the
connection for the bus base module of the module
aligned to the right (B).
Place the bus base module of the left-alignable Ethernet
interface on the DIN rail (C).
Push the left-alignable Ethernet interface bus base
module into the connection for the special bus base
module of the controller (D).
Figure 7
•
Inserting supply connector
Place all supply connectors in position and press firmly.
Make sure that the respective locking latch snaps in.
Align additional AXC F XT ... modules on the left (in
preparation):
SZS 1,0X4,0 VDE
A
Figure 6
•
C B
Mounting the bus base modules of further
AXC F XT ... modules
Remove the cover cap of the preceding bus base
module (A).
107237_en_01
PHOENIX CONTACT
8 / 12
AXC F XT ETH 1TX
8
Connecting the supply voltage and
Ethernet
8.1
Connecting the supply voltage
Please note:
The supply voltage of the controller and the
left-alignable Ethernet interface must be fed in
via a shared power supply unit.
•
Connect the supply voltage via the Axioline F
connector.
TermiColor
Assignment
nal
point
Supply voltage input
Supply voltage feed-in
a1, a2
Red
24 V DC
(bridged internally)
(UL)
b1, b2
Blue
GND
Reference potential of
the supply voltage
(bridged internally)
8.2
Connect the Ethernet network to the RJ45 socket.
SD-CARD
MAC Addr.: XX.XX.XX.XX.XX.XX
Ord. No. 2404267 AXC
F 2152
•
Connecting Ethernet
R
•
X4
•
Use an Ethernet cable that complies with
at least CAT5 of IEEE 802.3.
Observe the bending radii of the Ethernet
cable used.
LNK
UL
ACT
X2
X1
24 V
GND
Figure 10
Connecting Ethernet
Pin assignment
Figure 8
Connecting the supply voltage
1
Terminal point assignment
2
3
a1
a2
a1
b1
a2
b2
b1
b2
RJ45
4
5
6
7
Figure 9
8
Terminal point assignment
Figure 11
107237_en_01
Pin assignment of the Ethernet socket (RJ45)
PHOENIX CONTACT
9 / 12
AXC F XT ETH 1TX
With the left-alignable Ethernet interface, you are extending
the PLCnext controller by adding another separate network
interface. You can thus realize two networks that are
independent of each other:
Connection example
I/O
I/O
2
...
RJ45 RJ45 RJ45
1
1
Figure 13
Example application
Key:
1
9
Application example
AXC F 2152
1000Base-T (1000 Mbps)
Pin
Assignment
1
DA+ (bidirectional)
2
DA- (bidirectional)
3
DB+ (bidirectional)
4
DC+ (bidirectional)
5
DC- (bidirectional)
6
DB- (bidirectional)
7
DD+ (bidirectional)
8
DD- (bidirectional)
10
AXC F XT ETH 1TX
10Base-T (10 Mbps)/100Base-T (100 Mbps)
Pin
Assignment
1
TxD + (transmit data +)
2
TxD - (transmit data -)
3
RxD+ (receive data +)
4
Reserved
5
Reserved
6
RxD- (receive data -)
7
Reserved
8
Reserved
2
Network 1: Communication with the I/O level, e. g., as
a PROFINET controller
Network 2: Communication with a control system
24 V DC +(UL)
Figure 12
107237_en_01
Connection of the cables
PHOENIX CONTACT
10 / 12
AXC F XT ETH 1TX
11
Diagnostics and status indicators
11.1
Diagnostics and status indicators of the left-alignable Ethernet interface
LNK
UL
ACT
24 V DC +
(UL)
Figure 14
Diagnostics and status indicators of the left-alignable Ethernet interface
Designation
UL
Color
Green
Meaning
Communications power
LNK
Green
Link status
ACT
Yellow
Activity status
107237_en_01
State
On
Description
Communications power present.
Off
On
Off
On
Off
Communications power not present.
Connection active
Connection not active
Data transmission active
No data transmission
PHOENIX CONTACT
11 / 12
AXC F XT ETH 1TX
11.2
Diagnostic indicators of the controller
EXT
Figure 15
Diagnostic indicators of the controller
The controller has an LED for diagnosing Axioline F
extension modules that are aligned to the left.
For information on all other LEDs, please refer
to the user manual for the controller you are
using.
Designation
EXT
Color
Red
Yellow
Green
107237_en_01
Meaning
Left alignment
State
On
On
On
Description
Error at extension module
Possible error causes:
- Extension module is not supported.
- Extension module is not mounted correctly or is defective.
- Extension module was disconnected from power during operation or has been removed.
Test of the extension module during the boot procedure
Extension module operating without errors
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
phoenixcontact.com
12 / 12