2403115

2403115

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    COMMUNICATIONS MODULE 19.2-30V

  • 数据手册
  • 价格&库存
2403115 数据手册
AXC F XT ETH 1TX Axioline F, left-alignable Ethernet interface Data sheet 107237_en_01 1 © PHOENIX CONTACT 2019-03-04 Description An AXC F ... PLCnext controller can be extended with an additional Ethernet interface using the AXC F XT ETH 1TX left-alignable extension module. Features – – – – – Individual expansion option for PLCnext Controls of the Axiocontrol series Left-alignable Gigabit-class Ethernet interface Additional independent MAC address PROFINET support Electrical isolation between Ethernet interface and logic Ensure that the left-alignable Ethernet interface is only aligned next to a PLCnext controller which has a firmware version that is permissible for this. AXC F ... PLCnext controllers with the following firmware versions are permitted: – AXC F 2152 with firmware version  2019.0 LTS This data sheet is only valid in association with the UM EN AXL F SYS INST user manual. For information on PROFINET basics, please refer to the UM EN PROFINET SYS user manual. Make sure you always use the latest documentation. It can be downloaded at: phoenixcontact.net/product/2403115 AXC F XT ETH 1TX 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 4 5 Internal circuit diagram ............................................................................................................ 6 6 Module components ................................................................................................................ 6 7 Mounting.................................................................................................................................. 7 7.1 Removing the controller supply connector.................................................................................. 7 7.2 Removing other connectors from the controller ........................................................................... 7 7.3 Removing electronics modules ............................................................................................... 7 7.4 Snapping on electronics modules ............................................................................................ 8 7.5 Inserting supply connector ..................................................................................................... 8 8 Connecting the supply voltage and Ethernet ........................................................................... 9 8.1 Connecting the supply voltage ................................................................................................ 9 8.2 Connecting Ethernet ............................................................................................................. 9 9 Connection example.............................................................................................................. 10 10 Application example .............................................................................................................. 10 11 Diagnostics and status indicators .......................................................................................... 11 11.1 Diagnostics and status indicators of the left-alignable Ethernet interface.......................................... 11 11.2 Diagnostic indicators of the controller ..................................................................................... 12 107237_en_01 PHOENIX CONTACT 2 / 12 AXC F XT ETH 1TX 3 Ordering data Description Type Order No. Pcs./Pkt. Left-alignable Ethernet interface, for connection to a AXC F XT ETH 1TX compatible modular controller from the Axiocontrol range. 2403115 1 Accessories Type Order No. Pcs./Pkt. PLCnext Control for the direct control of Axioline F I/Os. With two Ethernet interfaces. Complete with connector and bus base module. AXC F 2152 2404267 1 Bus base for extension modules that can be aligned to the AXC BS H XT left 2403678 5 Bus base module for left-aligning the AXC F 2xxx controllers AXC BS L 2 1064312 1 Axioline F short power connector (for e.g., AXL F BK ...) (Replacement item) AXL CN S/UL 2701421 5 Documentation Type Order No. Pcs./Pkt. User manual, English, Axioline F: System and installation UM EN AXL F SYS INST - - User manual, English, Axioline F: Diagnostic registers, and error messages UM EN AXL F SYS DIAG - - User manual, English, PROFINET basics UM EN PROFINET SYS - - 107237_en_01 PHOENIX CONTACT 3 / 12 AXC F XT ETH 1TX 4 Technical data Dimensions (nominal sizes in mm) 122,4 54 126,1 35 Width 35 mm Height 126.1 mm Depth 54 mm Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). General data Type modular Color traffic grey A RAL 7042 Weight 106 g (with connector and bus base module) Ambient temperature (operation) -25 °C ... 60 °C (up to 2000 m above sea level) Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 5 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 58 kPa ... 106 kPa (up to 4500 m above mean sea level) Degree of protection IP20 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Mounting type DIN rail mounting Connection data: Axioline F connector Connection method Push-in connection Conductor cross section solid / stranded 0.2 mm² ... 1.5 mm² / 0.2 mm² ... 1.5 mm² Conductor cross section [AWG] 24 ... 16 Stripping length 8 mm Interface Ethernet Number of interfaces 1 Connection method RJ45 socket Note on the connection method Auto negotiation and autocrossing 107237_en_01 PHOENIX CONTACT 4 / 12 AXC F XT ETH 1TX Interface Ethernet Bus system RJ45 Transmission speed 10/100/1000 Mbps (full duplex) Transmission length max. 100 m Interface Axioline F local bus Number of interfaces 1 Connection method Bus base module Transmission speed 100 Mbps Supply of the logic voltage UL Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Polarity reversal protection of the supply voltage Polarity protection diode Transient protection Suppressor diode NOTE: Damage to the electronics Provide external protection for the module. Error messages to the higher level control or computer system None Mechanical tests Vibration resistance in acc. with EN 60068-2-6/ IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g Continuous shock according to EN 60068-2-27/ IEC 60068-2-27 10g Conformance with EMC Directive 2014/30/EU Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/ IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV Transient overvoltage (surge) EN 61000-4-5/ IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/ asymmetrical) Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V Noise emission test according to EN 61000-6-3 Class B Approvals For the latest approvals, please visit phoenixcontact.net/products. 107237_en_01 PHOENIX CONTACT 5 / 12 AXC F XT ETH 1TX 5 Internal circuit diagram Ethernet 6 Module components Logic / FE 5 RJ45 6 LNK ACT Chipset UL UL VCC 4 Extension bus 1 24V 3 2 UL 24 V Figure 1 Basic circuit diagram Key: RJ45 RJ45 interface LED Power supply unit with electrical isolation Figure 2 1 2 3 4 5 6 Module components Bus base module Electronics module Supply connector Function identification Diagnostic and status indicators Ethernet interface Power supply unit XXX XXX Chipset Extension bus 107237_en_01 Chipset Axioline F extension modules aligned to the left PHOENIX CONTACT 6 / 12 AXC F XT ETH 1TX 7.3 Mounting Before the left-alignable Ethernet interface can be aligned to the controller, you must remove the controller electronics module. To do this, proceed as follows: • Insert a suitable tool (e.g., bladed screwdriver) into the upper and lower snap-on mechanisms (base latches) of the controller/module one after the other and release it (A). The base latches are locked in place in the open position. • Remove the electronics module vertically out of the DIN rail (B). A A X X .X X .X X .X X D .X R A C 4 r.: X O rd .N o. 24 04 26 7 R A -C A dd D Release the locking latch (A), tilt the supply connector upwards slightly (B), and remove it from the controller (C). .X X C F 21 52 B Removing the controller supply connector S 1 X 2 X X 2 X 1 A X X r.: o. .N rd O M dd A A 7 26 04 24 C A X X X .X X X .X 21 F C X .X 52 .X .X X 4 R S D -C A R D • In the case of AXC ... controllers, you must also remove the electronics module of the first module aligned to the right. X Mount all the modules required before supplying power to the Axioline F station. Modules to which power is only supplied following the controller boot process are not detected or may result in a malfunction. To ensure that the left-alignable Ethernet interface is detected correctly, proceed as follows: – Switch on the power to the left-alignable Ethernet interface before switching on the power to the controller OR – Switch on the power to the left-alignable Ethernet interface and to the controller simultaneously. X Please note: 7.1 Removing electronics modules M 7 Removing the electronics module X 1 X 2 Figure 4 To operate the left-alignable Ethernet interface on a controller for Axioline F, a special bus base module is required for the respective controller. The bus base module is not supplied as standard with AXC ... controllers. For the ordering data, please refer to the user manual for the controller you are using. In the case of AXC ... controllers, you must first replace the existing bus base module with the special bus base module. Figure 3 7.2 • Removing the supply connector Removing other connectors from the controller Remove all other connectors from the controller. To do this, proceed as follows: • Remove the controller bus base module from the bus base of the first module aligned to the right. • Remove the controller bus base module from the DIN rail. Proceed as follows to mount the special bus base module: 107237_en_01 PHOENIX CONTACT 7 / 12 AXC F XT ETH 1TX • C D • A B 7.4 • 7.5 Figure 5 • • • • Place the bus base modules of the additional AXC F XT ... modules to be aligned on the left on the DIN rail (B). Push each subsequent bus base module into the connection of the previous bus base module (C). Snapping on electronics modules Working from right to left, place each electronics module vertically on the corresponding bus base module and on the DIN rail until it snaps into place with a click. Make sure that the device plug for the bus base connection is situated above the corresponding socket on the bus base module. Inserting supply connector A Mount bus base module(s) Place the special controller bus base module on the DIN rail (A). Push the special controller bus base module into the connection for the bus base module of the module aligned to the right (B). Place the bus base module of the left-alignable Ethernet interface on the DIN rail (C). Push the left-alignable Ethernet interface bus base module into the connection for the special bus base module of the controller (D). Figure 7 • Inserting supply connector Place all supply connectors in position and press firmly. Make sure that the respective locking latch snaps in. Align additional AXC F XT ... modules on the left (in preparation): SZS 1,0X4,0 VDE A Figure 6 • C B Mounting the bus base modules of further AXC F XT ... modules Remove the cover cap of the preceding bus base module (A). 107237_en_01 PHOENIX CONTACT 8 / 12 AXC F XT ETH 1TX 8 Connecting the supply voltage and Ethernet 8.1 Connecting the supply voltage Please note: The supply voltage of the controller and the left-alignable Ethernet interface must be fed in via a shared power supply unit. • Connect the supply voltage via the Axioline F connector. TermiColor Assignment nal point Supply voltage input Supply voltage feed-in a1, a2 Red 24 V DC (bridged internally) (UL) b1, b2 Blue GND Reference potential of the supply voltage (bridged internally) 8.2 Connect the Ethernet network to the RJ45 socket. SD-CARD MAC Addr.: XX.XX.XX.XX.XX.XX Ord. No. 2404267 AXC F 2152 • Connecting Ethernet R • X4 • Use an Ethernet cable that complies with at least CAT5 of IEEE 802.3. Observe the bending radii of the Ethernet cable used. LNK UL ACT X2 X1 24 V GND Figure 10 Connecting Ethernet Pin assignment Figure 8 Connecting the supply voltage 1 Terminal point assignment 2 3 a1 a2 a1 b1 a2 b2 b1 b2 RJ45 4 5 6 7 Figure 9 8 Terminal point assignment Figure 11 107237_en_01 Pin assignment of the Ethernet socket (RJ45) PHOENIX CONTACT 9 / 12 AXC F XT ETH 1TX With the left-alignable Ethernet interface, you are extending the PLCnext controller by adding another separate network interface. You can thus realize two networks that are independent of each other: Connection example I/O I/O 2 ... RJ45 RJ45 RJ45 1 1 Figure 13 Example application Key: 1 9 Application example AXC F 2152 1000Base-T (1000 Mbps) Pin Assignment 1 DA+ (bidirectional) 2 DA- (bidirectional) 3 DB+ (bidirectional) 4 DC+ (bidirectional) 5 DC- (bidirectional) 6 DB- (bidirectional) 7 DD+ (bidirectional) 8 DD- (bidirectional) 10 AXC F XT ETH 1TX 10Base-T (10 Mbps)/100Base-T (100 Mbps) Pin Assignment 1 TxD + (transmit data +) 2 TxD - (transmit data -) 3 RxD+ (receive data +) 4 Reserved 5 Reserved 6 RxD- (receive data -) 7 Reserved 8 Reserved 2 Network 1: Communication with the I/O level, e. g., as a PROFINET controller Network 2: Communication with a control system 24 V DC +(UL) Figure 12 107237_en_01 Connection of the cables PHOENIX CONTACT 10 / 12 AXC F XT ETH 1TX 11 Diagnostics and status indicators 11.1 Diagnostics and status indicators of the left-alignable Ethernet interface LNK UL ACT 24 V DC + (UL) Figure 14 Diagnostics and status indicators of the left-alignable Ethernet interface Designation UL Color Green Meaning Communications power LNK Green Link status ACT Yellow Activity status 107237_en_01 State On Description Communications power present. Off On Off On Off Communications power not present. Connection active Connection not active Data transmission active No data transmission PHOENIX CONTACT 11 / 12 AXC F XT ETH 1TX 11.2 Diagnostic indicators of the controller EXT Figure 15 Diagnostic indicators of the controller The controller has an LED for diagnosing Axioline F extension modules that are aligned to the left. For information on all other LEDs, please refer to the user manual for the controller you are using. Designation EXT Color Red Yellow Green 107237_en_01 Meaning Left alignment State On On On Description Error at extension module Possible error causes: - Extension module is not supported. - Extension module is not mounted correctly or is defective. - Extension module was disconnected from power during operation or has been removed. Test of the extension module during the boot procedure Extension module operating without errors PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com 12 / 12
2403115 价格&库存

很抱歉,暂时无法提供与“2403115”相匹配的价格&库存,您可以联系我们找货

免费人工找货