0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2688051

2688051

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    OUTPUTMODULE32SOLIDSTATE24V

  • 数据手册
  • 价格&库存
2688051 数据手册
https://www.phoenixcontact.com/us/products/2688051 I/O module - AXL F DO32/1 1F - 2688051 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Axioline F, Digital output, Digital outputs: 32, 24 V DC, 500 mA, 1-wire, Transmission speed in the local bus 100 MBit/s, Degree of protection IP20, including bus base module and Axioline F connectors Product Description The module is designed for use within an Axioline˽F station. It is used to output digital signals. The outputs are protected against short circuit and overload. Product Features ■ ■ ■ ■ ■ ■ 32 digital outputs 24 V DC, 500 mA Connection of actuators in single-wire technology Minimum update time of < 100 μs Device rating plate stored Diagnostic and status indicators Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 240.0 g Custom tariff number 85389091 Country of origin Germany Technical data Dimensions Width 53.6 mm Height 126.1 mm Depth 54 mm Note on dimensions The depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715). 04/28/2016   Page 1 / 6 https://www.phoenixcontact.com/us/products/2688051 I/O module - AXL F DO32/1 1F - 2688051 Technical data Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Connection data Designation Axioline F connector Connection method Push-in connection Note on connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm General Mounting type DIN rail Net weight 240 g Note on weight specifications with connectors and bus base module Diagnostics messages Short-circuit / overload of the digital outputs Yes Interfaces Designation Axioline F local bus Connection method Bus base module Transmission speed 100 MBit/s Axioline potentials Communications power UBus 5 V DC (via bus base module) Current consumption from UBus max. 120 mA Supply of digital output modules UO 24 V DC Current consumption from UO max. 8 A (external fuse) Digital outputs Output name Digital outputs 04/28/2016   Page 2 / 6 https://www.phoenixcontact.com/us/products/2688051 I/O module - AXL F DO32/1 1F - 2688051 Technical data Digital outputs Connection method Push-in connection 1-wire Number of outputs 32 Protective circuit Short-circuit protection, overload protection of the outputs Electronic Output voltage 24 V Nominal output voltage 24 V DC Maximum output current per channel 500 mA Maximum output current per module 8 A (external fuse) Nominal load, inductive max. 12 VA (1.2 H, 48 Ω, with nominal voltage) Nominal load, lamp max. 12 W (at nominal voltage) Nominal load, ohmic max. 12 W (48 Ω; with nominal voltage) Standards and Regulations Conformity with EMC directives Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical) Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B Test section 5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min. 5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min. 24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min. Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Protection class III, IEC 61140, EN 61140, VDE 0140-1 Classifications eCl@ss eCl@ss 4.0 27240404 eCl@ss 4.1 27240404 04/28/2016   Page 3 / 6 https://www.phoenixcontact.com/us/products/2688051 I/O module - AXL F DO32/1 1F - 2688051 Classifications eCl@ss eCl@ss 5.0 27242204 eCl@ss 5.1 27242604 eCl@ss 6.0 27242604 eCl@ss 7.0 27242604 eCl@ss 8.0 27242604 eCl@ss 9.0 27242604 ETIM ETIM 4.0 EC001601 ETIM 5.0 EC001599 UNSPSC UNSPSC 6.01 43172015 UNSPSC 7.0901 43201404 UNSPSC 11 39121311 UNSPSC 12.01 39121311 UNSPSC 13.2 39121311 Approvals Approvals Approvals UL Listed / cUL Listed / BSH / RINA / LR / BV / ABS / EAC / cULus Listed Ex Approvals Approvals submitted Approval details UL Listed  04/28/2016   Page 4 / 6 https://www.phoenixcontact.com/us/products/2688051 I/O module - AXL F DO32/1 1F - 2688051 Approvals cUL Listed  BSH  RINA  LR  BV  ABS  EAC  cULus Listed  Drawings Connection diagram 02 03 04 05 06 07 10 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27 30 31 32 33 34 35 36 37 53,6 54 OUT8 OUT32 126,1 OUT25 01 122,4 OUT1 00 Dimensional drawing 04/28/2016   Page 5 / 6 https://www.phoenixcontact.com/us/products/2688051 I/O module - AXL F DO32/1 1F - 2688051 Diagram UBus 4x µC Local bus D UO E1 00 06 07 36 37 06 07 Output circuit 32x 16 17 00 06 07 36 Energy consumption [J] Block diagram 1,2 Only with external free running circuit 1,0 1 = 0,5 A 2 = 0,4 A 3 = 0,3 A 4 = 0,2 A 5 = 0,1 A 0,8 0,6 0,4 1 2 3 4 0,2 5 0 0 0,4 0,8 1,2 1,6 2,0 2,4 2,8 3,2 3,6 4,0 4,4 4,8 5,2 5,6 6,0 6,4 6,8 7,2 Inductance [H] 37 26 27 Maximum outputs power consumption when inductive loads are switched off 36 37 UO 24 V DO 1...32 Internal wiring of the terminal points Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 04/28/2016   Page 6 / 6
2688051 价格&库存

很抱歉,暂时无法提供与“2688051”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2688051
    •  国内价格 香港价格
    • 1+4000.558731+497.03220

    库存:3

    2688051
      •  国内价格
      • 1+552.74017

      库存:2