The module is designed for use within an Axioline station.
On the one hand, it is used to acquire fast pulse sequences from sensors, and on the other hand to detect positions using incremental encoders.
The module combines two counter inputs for the evaluation of fast counter pulses and two incremental encoder inputs for position detection.
Product Features
2 counter inputs
2 incremental encoder inputs
Maximum input frequency: 300 kHz/100 kHz (depending on the wiring)
32-bit counter (up and down)
Output control according to two limit values
Counter: counting (source) is controlled via a control input (gate)
Counter: single or periodic counting
Incremental encoder acquisition: acquisition of digital signals from symmetrical and asymmetrical incremental encoders
Incremental encoder acquisition: evaluation of linear or rotary axes
Device rating plate stored
Diagnostic and status indicators
Key commercial data
Packing unit
1 pc
Weight per Piece (excluding packing)
240.0 GRM
Custom tariff number
85389091
Country of origin
Germany
Technical data
Dimensions
Width
53.6 mm
09/03/2014 Page 1 / 7
https://www.phoenixcontact.com/us/products/2688093
Special function module - AXL CNT 2/INC 2 - 2688093
Technical data
Dimensions
Height
126.1 mm
Depth
54 mm
Note on dimensions
The depth is valid when a TH 35-7.5 DIN rail is used (according to
EN 60715).
Ambient conditions
Ambient temperature (operation)
-25 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
5 % ... 95 % (non-condensing)
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protection
IP20
General
Weight
205 g
Note on weight specifications
with connectors and bus base module
Mounting type
DIN rail
Protection class
III, IEC 61140, EN 61140, VDE 0140-1
Test section
5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min
Conformance with EMC directives
Noise immunity test in accordance with EN 61000-6-2 Electrostatic
discharge (ESD) EN 61000‑4‑2/IEC 61000‑4‑2 Criterion B; 6 kV contact
discharge, 8 kV air discharge
Noise immunity test in accordance with EN 61000-6-2 Electromagnetic
fields EN 61000‑4‑3/IEC 61000‑4‑3 Criterion A; Field intensity: 10 V/m
Noise immunity test in accordance with EN 61000-6-2 Fast transients
(burst) EN 61000‑4‑4/IEC 61000‑4‑4 Criterion B, 2 kV
Noise immunity test in accordance with EN 61000-6-2 Transient surge
voltage (surge) EN 61000‑4‑5/IEC 61000‑4‑5 Criterion B; DC supply lines:
±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Noise immunity test in accordance with EN 61000-6-2 Conducted
interference EN 61000‑4‑6/IEC 61000‑4‑6 Criterion A; Test voltage 10 V
Noise emission test according to EN 61000-6-3 Radio interference
properties EN 55022 Class B
Mechanical tests
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Diagnostics messages
Short-circuit / overload of the digital outputs Yes
Error at the symmetrical incremental encoder Yes
09/03/2014 Page 2 / 7
https://www.phoenixcontact.com/us/products/2688093
Special function module - AXL CNT 2/INC 2 - 2688093
Technical data
Interfaces
Designation
Axioline F local bus
Connection method
Bus base module
Transmission speed
100 MBit/s
Axioline potentials
Communications power UBus
5 V DC (via bus base module)
Current consumption from UBus
typ. 100 mA
max. 120 mA
Supply of digital input modules UI
24 V DC
Current consumption from UI
typ. 50.5 mA (Own current consumption; without wiring of the terminal
points)
max. 2.5 A (dependent on the encoder or sensor type used and the load
on the digital output.)
Counter inputs
Number of inputs
2 (S1, S2)
Description of the input
EN 61131-2, type 3
Connection method
Push-in technology
Input voltage
24 V DC
Input voltage range "0" signal
-3 V DC ... 5 V DC
Input voltage range "1" signal
11 V DC ... 30 V DC
Input frequency
max. 300 kHz (1 channel wired)
max. 100 kHz (More than one channel wired or Z signal monitoring via the
firmware)
Input current
2.5 mA (per channel)
Resolution
32
Permissible cable length to the sensor
30 m
Encoder inputs
Input name
Incremental encoder inputs
Number of inputs
2 (A1, /A1, B1, /B1, Z1, /Z1; A2, /A2, B2, /B2, Z2, /Z2)
Connection method
Push-in technology
Encoder signals
Symmetrical and asymmetrical encoders
Cable length
30 m
Encoder data
Number of 5 V encoder supplies
2 (UE1, UE2)
Nominal output voltage
5 V DC
Voltage range
5 V DC ... 5.5 V DC
Current carrying capacity
max. 250 mA
09/03/2014 Page 3 / 7
https://www.phoenixcontact.com/us/products/2688093
Special function module - AXL CNT 2/INC 2 - 2688093
Technical data
Encoder data
Type of protection
Short-circuit protection
Protective circuit/component
Electronic
Number of 24 V encoder supplies
2 (US1, US2)
Nominal output voltage
24 V DC
Voltage range
19.2 V DC ... 30 V DC
Current carrying capacity
typ. 500 mA
Type of protection
Short-circuit protection
Protective circuit/component
Electronic
Designation
Symmetrical incremental encoders
Encoder types that can be connected
max. 2 (A, /A, B, /B, (Z, /Z))
Type of connection of signals
Push-in technology
Encoder supply voltage
5 V DC
24 V DC
Signal voltage level
Differential signal (signal – inverted signal) ±0.5 V, minimum; ±6 V,
maximum
Common mode voltage range signal - ground
-10 V ... 13.2 V
Input frequency
max. 300 kHz (1 channel wired)
max. 100 kHz (More than one channel wired or Z signal monitoring via the
firmware)
Designation
Asymmetrical incremental encoders
Encoder types that can be connected
max. 2 (A, B, (Z))
Type of connection of signals
Push-in technology
Signal voltage level
Low ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum)
Input frequency
max. 300 kHz (1 channel wired)
max. 100 kHz (More than one channel wired or Z signal monitoring via the
firmware)
Digital inputs
Input name
Digital inputs
Description of the input
EN 61131-2, type 3
Connection method
Push-in technology
1-wire (optionally 2, 3-wire)
Number of inputs
8 (CNT: G1, G2, Dir1, Dir2; INC: Ref1, Ref2, L1, L2)
Input voltage range "0" signal
-3 V DC ... 5 V DC
Input voltage range "1" signal
11 V DC ... 30 V DC
Nominal input current at UIN
2.5 mA (per channel)
Digital outputs
Output name
Digital outputs
09/03/2014 Page 4 / 7
https://www.phoenixcontact.com/us/products/2688093
Special function module - AXL CNT 2/INC 2 - 2688093
Technical data
Digital outputs
Connection method
Push-in technology
1-wire
Number of outputs
2 (Out1, Out2)
Protective circuit
Short-circuit protection, overload protection of the outputs
Output voltage
24 V DC
Nominal output voltage
24 V DC
Maximum output current per channel
500 mA
Nominal load, inductive
max. 12 VA (1.2 H; 48 Ω; with nominal voltage)
Nominal load, lamp
max. 12 W (at nominal voltage)
Nominal load, ohmic
max. 12 W (48 Ω; with nominal voltage)
Classifications
eCl@ss
eCl@ss 4.0
27240409
eCl@ss 4.1
27240409
eCl@ss 5.0
27242205
eCl@ss 5.1
27242605
eCl@ss 6.0
27242605
eCl@ss 7.0
27242605
eCl@ss 8.0
27242605
ETIM
ETIM 4.0
EC001601
ETIM 5.0
EC001601
UNSPSC
UNSPSC 6.01
43172015
UNSPSC 7.0901
43201404
UNSPSC 11
39121311
UNSPSC 12.01
39121311
UNSPSC 13.2
39121311
Approvals
Approvals
09/03/2014 Page 5 / 7
https://www.phoenixcontact.com/us/products/2688093
Special function module - AXL CNT 2/INC 2 - 2688093
Approvals
Approvals
UL Listed / cUL Listed / BSH / RINA / DNV / cULus Listed
Ex Approvals
Approvals submitted
Approval details
UL Listed
cUL Listed
BSH
RINA
DNV
cULus Listed
Drawings
09/03/2014 Page 6 / 7
https://www.phoenixcontact.com/us/products/2688093
Special function module - AXL CNT 2/INC 2 - 2688093
Connection diagram
00
01
02
Dimensioned drawing
53,6
03
54
A /A
2
10
11
12
13
20
21
22
23
30
31
32
33
B /B
2
Z /Z
2
24 V DC
122,4
126,1
VCC
2
Block diagram
UBus
mC
Axio bus
Supervisor
FE
D
UI
E1
+5V DC
A
B
Z
UI
24 V
2x
Internal wiring of the terminal points