0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2688433

2688433

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    I/OMODULE1DIGITAL1ANALOG

  • 数据手册
  • 价格&库存
2688433 数据手册
https://www.phoenixcontact.com/us/products/2688433 Special function module - AXL SSI 1/AO 1 - 2688433 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Axioline special function module, 1 SSI interface for absolute encoder, 1 analog output: 0-10 V, ±10 V, 0-5 V, ±5 V, 0-20 mA, 4-20 mA, ±20 mA, 2-wire connection method (including bus base module and connectors) Product description The module is designed for use within an Axioline station. It is used to acquire data from absolute encoders with SSI interface with a maximum resolution of up to 56 bits. The module supports encoders with Gray and binary code. Transmission speeds of up to 2 MHz are supported. In addition, the module has an analog output which can be used to specify setpoints, e.g., for electrical and hydraulic drives.   Product Features  Permanent surge protection against 24 V DC for all interfaces  Permanent short-circuit protection for all interfaces  Device rating plate stored  Diagnostic and status indicators  1 SSI interface  Monitoring of the 24 V encoder supply  Supports transmission speeds from 62.5 kHz to 2 MHz for SSI  8-bit to 56-bit resolution  Supports Gray and binary code  1 analog, bipolar output channel for the connection of either voltage or current signals  Connection of actuators in 2-wire technology  Voltage ranges: 0 V ... 10 V, ±10 V, 0 V ... 5 V, ±5 V  Current ranges: 0 mA ... 20 mA, 4 mA ... 20 mA, ±20 mA   Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 200.0 GRM Custom tariff number 85389091 Country of origin Germany 09/03/2014   Page 1 / 6 https://www.phoenixcontact.com/us/products/2688433 Special function module - AXL SSI 1/AO 1 - 2688433 Technical data Dimensions Width 35 mm Height 126.1 mm Depth 54 mm Note on dimensions The depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715). Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 5 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Connection data Designation Axioline F connector Connection method Push-in technology Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 1.5 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 16 Stripping length 8 mm General Weight 135 g Note on weight specifications with connectors and bus base module Mounting type DIN rail Protection class III, IEC 61140, EN 61140, VDE 0140-1 Test section Logic 500 V AC 50 Hz 1 min SSI I/O (24 V supply) 500 V AC 50 Hz 1 min Functional earth ground 500 V AC 50 Hz 1 min Analog I/O 500 V AC 50 Hz 1 min Conformance with EMC directives Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000‑4‑2/IEC 61000‑4‑2 Criterion B; 6 kV contact discharge, 8 kV air discharge Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000‑4‑3/IEC 61000‑4‑3 Criterion A; Field intensity: 10 V/m 09/03/2014   Page 2 / 6 https://www.phoenixcontact.com/us/products/2688433 Special function module - AXL SSI 1/AO 1 - 2688433 Technical data General Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000‑4‑4/IEC 61000‑4‑4 Criterion B, 2 kV Noise immunity test in accordance with EN 61000-6-2 Transient surge voltage (surge) EN 61000‑4‑5/IEC 61000‑4‑5 Criterion B; supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); ±1 kV to shielded I/O cables Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000‑4‑6/IEC 61000‑4‑6 Criterion A; Test voltage 10 V Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Interfaces Designation Axioline F local bus Connection method Bus base module Transmission speed 100 MBit/s Axioline potentials Communications power UBus 5 V DC (via bus base module) Current consumption from UBus max. 140 mA Supply of digital input modules UI 24 V DC Current consumption from UI max. 60 mA (Supply of the SSI interface and the analog output (20 mA), without sensor supply) Encoder inputs Input name SSI interface Description of the input RS-422 interface according to SSI specification Number of inputs 1 Connection method Push-in technology Encoder signals Single-turn and multi-turn encoder, length measuring sticks Input frequency to 2 MHz (Can be parameterized: 67.5 kHz, 125 kHz (default), 250 kHz, 500 kHz, 1 MHz, 2 MHz) Parity Even, odd or no parity Transmission frequency 2 MHz Adjustable resolution 8 ... 56 Encoder supply voltage 24 V DC (UI - 0.5 V) Encoder data Nominal output voltage 24 V DC (UI - 0.5 V) Voltage range 19.5 V DC ... 30 V DC (including all tolerances, including ripple) Current carrying capacity max. 500 mA 09/03/2014   Page 3 / 6 https://www.phoenixcontact.com/us/products/2688433 Special function module - AXL SSI 1/AO 1 - 2688433 Technical data Encoder data Type of protection Surge protection Protective circuit/component Electronic (35 V, 0.5 s) Analog outputs Number of outputs 1 Connection method Push-in technology 2-wire (shielded, twisted pair) Output name Analog outputs D/A conversion time 5 µs D/A resolution 16 bit Type of protection Surge protection Short-circuit and overload protection Transient protection Protective circuit/component Electronic (35 V, permanent) Electronic Suppressor diode Data formats IB IL, S7-compatible Measured value representation 16 bits Representation of output values 16 bits (15 bits + sign) Current output signal 0 mA ... 20 mA 4 mA ... 20 mA -20 mA ... 20 mA Load/output load current output max. 500 Ω Voltage output signal 0 V ... 5 V -5 V ... 5 V 0 V ... 10 V -10 V ... 10 V Load/output load voltage output > 2 kΩ Precision typ. 0.1 % (of output range final value) typ. 0.1 % (of output range final value) Permissible cable length max. 250 m Classifications eCl@ss eCl@ss 4.0 27240405 eCl@ss 4.1 27240405 eCl@ss 5.0 27242201 09/03/2014   Page 4 / 6 https://www.phoenixcontact.com/us/products/2688433 Special function module - AXL SSI 1/AO 1 - 2688433 Classifications eCl@ss eCl@ss 5.1 27242601 eCl@ss 6.0 27242601 eCl@ss 7.0 27242601 eCl@ss 8.0 27242605 ETIM ETIM 3.0 EC001599 ETIM 4.0 EC001601 ETIM 5.0 EC001599 UNSPSC UNSPSC 6.01 43172015 UNSPSC 7.0901 43201404 UNSPSC 11 39121311 UNSPSC 12.01 39121311 UNSPSC 13.2 39121311 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approvals submitted Approval details UL Listed  09/03/2014   Page 5 / 6 https://www.phoenixcontact.com/us/products/2688433 Special function module - AXL SSI 1/AO 1 - 2688433 Approvals cUL Listed  cULus Listed  Drawings Connection diagram 00 01 02 Dimensioned drawing 35 03 54 U, I 10 11 12 13 AGND T /T 2 2 D /D U, I 122,4 GND 126,1 US SSI Block diagram UBus Supervisor mC Axio bus FE # U D UA E1 E2 00 10 01 11 02 12 U/I ELF UI 24 V SSI REF 03 13 US AO Internal wiring of the terminal points Phoenix Contact 2014 © - all rights reserved http://www.phoenixcontact.com 09/03/2014   Page 6 / 6
2688433 价格&库存

很抱歉,暂时无法提供与“2688433”相匹配的价格&库存,您可以联系我们找货

免费人工找货