2692306

2692306

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    INPUT MODULE 4 DIGITAL 24V

  • 数据手册
  • 价格&库存
2692306 数据手册
IB IL 24 DI 4 ... Inline terminal with 4 digital inputs Data Sheet 5550_en_05 © PHOENIX CONTACT - 05/2008 co 1 Description nt ne po om in ec – – Connections for four digital sensors Connection of sensors in 2 and 3-wire technology Maximum permissible load current per sensor: 250 mA Maximum permissible load current from the terminal: 1.0 A Diagnostic and status indicators Approved for the use in potentially explosive areas (observe the notes on page 7) on l – – – – Features s. The terminal is designed for use within an Inline station. It is used to acquire digital input signals. 1.1 m AUTOMATION This data sheet is only valid in association with the IL SYS INST UM E user manual. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for the products listed on the following page: IB IL 24 DI 4 ... 2 Ordering data Products Description Order No. Pcs./Pkt. IB IL 24 DI 4-PAC 2861234 1 Inline terminal with four digital inputs; without accessories; transmission speed of 500 kbps IB IL 24 DI 4 2726214 1 Inline terminal with four digital inputs; complete with accessories (connector and labeling field); transmission speed of 2 Mbps IB IL 24 DI 4-2MBD-PAC 2692306 1 Inline terminal with four digital inputs; without accessories; transmission speed of 2 Mbps IB IL 24 DI 4-2MBD 2855017 1 m Type Inline terminal with four digital inputs; complete with accessories (connector and labeling field); transmission speed of 500 kbps co One of the connectors listed below is needed for the complete fitting of the IB IL 24 DI 4 and IB IL 24 DI 4-2MBD terminals. Type Connector for digital 4-channel or 16-channel Inline terminals, w/o color print IB IL SCN-12 2726340 1 Connector for digital 4-channel or 16-channel Inline input terminals, with color print IB IL SCN-12-ICP 2727611 1 ne nt s. Accessories Description Documentation Description po Type Order No. Pcs./Pkt. Order No. Pcs./Pkt. 2698737 1 "Automation Terminals of the Inline Product Range" user manual IL SYS INST UM E "INTERBUS Addressing" data sheet DB GB IBS SYS ADDRESS 9000990 1 AH EN IL EX ZONE 2 – – Technical data General data in ec 3 om "Inline Terminals for Use in Zone 2 Potentially Explosive Areas" application note Housing dimensions (width x height x depth) Weight Operating mode 12.2 mm x 141 mm x 72 mm (with connectors) 44 g (without connector), 66 g (with connector) Process data operation with 4 bit (1 nibble) 2 and 3-wire technology -25°C to +55°C Ambient temperature (storage/transport) -25°C to +85°C on l Connection method for sensors Ambient temperatures (operation) Permissible humidity (operation/storage/transport) 10% to 95% according to DIN EN 61131-2 Permissible air pressure (operation/storage/transport) 70 kPa to 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Class of protection III, IEC 61140 Connection data for Inline connector Connection type Spring-cage terminals Conductor cross-section 0.2 mm2 to 1.5 mm2 (solid or stranded), 24 - 16 AWG Interface Local bus 5550_en_05 Through data routing PHOENIX CONTACT 2 IB IL 24 DI 4 ... Transmission speed IB IL 24 DI 4, IB IL 24 DI 4-PAC 500 kbps IB IL 24 DI 4-2MBD, IB IL 24 DI 4-2MBD-PAC 2 Mbps Power consumption 500 kbps Communications power 7.5 V 7.5 V Current consumption at UL 40 mA, maximum 51 mA, maximum 2 Mbps 0.3 W, maximum 0.4 W, maximum 24 V DC (nominal value) 24 V DC (nominal value) Nominal current consumption at US 1.0 A, maximum 1.0 A, maximum Supply of the module electronics and I/O through bus coupler/power terminal Via potential routing co Connection method m Power consumption at UL Segment supply voltage US Digital inputs 4 Input design According to EN 61131-2, Type 1 Definition of switching thresholds ULmax < 5 V nt Maximum low-level voltage s. Number UHmin > 15 V Minimum high-level voltage Segment supply, ground Nominal input voltage UIN 24 V DC ne Common potentials Permissible range -30 V < UIN < +30 V DC Nominal input current for UIN 3 mA, minimum po At 500 kbps At 2 Mbps 3 mA, typical None Permissible cable length to the sensor Use of AC sensors om Delay time 30 m (to ensure conformance with EMC Directive) AC sensors in the voltage range < UIN are limited in application (corresponding to the input design). in ec Characteristic curve: Current depending on the input voltage and the ambient temperature TA (at 500 kbps) Supply voltage Input current Input current acc. to t >= 20 s For TA = 25°C For TA = 55°C 18 V 24 V on l 30 V 3.0 mA 2.9 mA 2.5 mA 3.9 mA 3.8 mA 3.5 mA 4.5 mA 4.2 mA 3.0 mA The current is reduced depending on the ambient temperature TA and the number of inputs that are switched on (module internal temperature). Power dissipation Formula to calculate the power dissipation of the electronics n PTOT = 0.24 W + S [ UINi x 0.003 A ] i=1 ’ Where PTOT n UINi i Total power dissipation in the terminal Number of set inputs (n = 1 to 4) Input voltage of input i Index Power dissipation of the housing PHOU 0.6 W, maximum (within the permissible operating temperature) 5550_en_05 PHOENIX CONTACT 3 IB IL 24 DI 4 ... Limitation of simultaneity, derating IB IL 24 DI 4, IB IL 24 DI 4-PAC (500 kbps) No limitation of simultaneity, no derating IB IL 24 DI 4-2MBD, IB IL 24 DI 4-2MBD-PAC (2 Mbps) U 30.0 V 28.5 20.0 20 30 40 45 °C 55 TA 5550A007 s. Safety equipment 10 co 0 m 10.0 No Surge voltage Protective elements in the power terminal Polarity reversal Protective elements in the power terminal ne nt Overload in segment circuit Electrical isolation po To provide electrical isolation between the logic level and the I/O area it is necessary to supply the station bus coupler and the digital input terminal described here via the bus coupler or a power terminal from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted. (See also IL SYS INST UM E user manual.) Common potentials The 24 V main voltage, 24 V segment voltage, and GND have the same potential. FE is a separate potential area. om Separate potentials in the system consisting of bus coupler/power terminal and I/O terminal Test distance Test voltage 5 V supply incoming remote bus/7.5 V supply (bus logic) in ec 5 V supply outgoing remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min 500 V AC, 50 Hz, 1 min 7.5 V supply (bus logic) / 24 V supply (I/O) 500 V AC, 50 Hz, 1 min 24 V supply (I/O) / functional earth ground 500 V AC, 50 Hz, 1 min None Approvals on l Error messages to the higher-level control or computer system For the latest approvals, please visit www.download.phoenixcontact.com or www.eshop.phoenixcontact.com. 5550_en_05 PHOENIX CONTACT 4 IB IL 24 DI 4 ... 4 Internal circuit diagram L o c a l b u s 5 Local diagnostic/status indicators and terminal point assignment O P C D 1 2 3 4 U L D I4 2 2 2 s. co m 2 1 1 .1 1 1 2 .1 1 .2 2 2 2 .2 3 3 2 .3 4 4 nt ne + 2 4 V (U S ) po + 2 4 V (U M ) 1 .3 1 .4 1 .5 om in ec Figure 1 2 1 .6 2 .4 5 6 6 2 .5 5 2 .6 5 5 5 0 B 0 0 2 5 5 5 0 C 0 0 3 Figure 2 Terminal with appropriate connector Internal wiring of the terminal points on l Key: Protocol chip (bus logic including voltage conditioning) OPC LED (status indicator) 5.1 Local diagnostic and status indicators Des. D 1, 2, 3, 4 5.2 Color Green Yellow Meaning Diagnostics Status indicators for the inputs Function identification Light blue Optocoupler 2MBD: White stripe in the vicinity of the D LED Digital input Electrically isolated area Other symbols used are explained in the IL SYS INST UM E user manual. 5550_en_05 PHOENIX CONTACT 5 IB IL 24 DI 4 ... Terminal point assignment 1.6, 2.6 When connecting the sensors observe the assignment of the terminal points to the process data (see page 8). D 1 2 3 4 D I4 2 s. 1 2 2 3 3 4 4 5 5 6 6 + 2 4 V IN 3 + 2 4 V IN 1 po om in ec on l 5550_en_05 A B A + 2 4 V ne A + 2 4 V 1 nt 1 IN 2 1.4 2.4 1.5, 2.5 Assignment Signal input 1 (IN 1) Signal input 2 (IN 2) Segment voltage US for 2 and 3-wire termination Ground contact (GND) for 3-wire termination Signal input 3 (IN 3) Signal input 4 (IN 4) Segment voltage US for 2 and 3-wire termination Ground contact (GND) for 3-wire termination IN 4 1.3, 2.3 Connection example m Terminal point 1.1 2.1 1.2, 2.2 6 co 5.3 5 5 5 0 A 0 0 4 Figure 3 A B Typical sensor connections 3-wire termination 2-wire termination PHOENIX CONTACT 6 IB IL 24 DI 4 ... 7 Notes on using the terminal in potentially explosive areas for the IB IL 24 DI 4 and IB IL 24 DI 4-PAC terminals Approval according to EC Directive EG-RL 94/9 (ATEX) II 3G EEx nAC IIC T4 U WARNING: Explosion hazard This Inline terminal conforms to standard EN 50021 and can be installed in a zone 2 potentially explosive area. This Inline terminal is a category 3 item of equipment. Before startup, ensure that the following points and instructions are observed. 4. Before using an Inline terminal in a zone 2 potentially explosive area, check that the terminal has been approved for installation in this area. 5. For a list of terminals approved for use in zone 2 potentially explosive areas, please refer to the AH EN IL EX ZONE 2 application note. II 3 G E E x n A C IIC T 4 U P o te n tia l r o u tin g 4 A m a x im u m fo r u s e in E x a r e a s IN T E R B U S G L U L x x L IS T E D 3 1 Z N P r o c . C tr l. E q p t. F o r H a z . L o c s . C l. I, Z n . 2 , A E x n C IIC T 5 C l. I, Z n . 2 , E x n C IIC T 5 C l. I, D iv . 2 , G r p . A ,B ,C ,D T 5 5550_en_05 5 5 6 1 B 0 0 1 Typical labeling of terminals for use in potentially explosive areas on l Figure 4 X X /- in ec IB x IL x x x x x O rd e r-N o .: x x x x x x x M o d u le - ID : x x H W /F W om po Check the labeling on the Inline terminal and the packaging (see Figure 4). ne WARNING: Explosion hazard Only use Inline terminals that are approved for use in potentially explosive areas. m 3. co 2. s. This Inline terminal of the indicated hardware version or later is suitable for use in Class I, Division 2, Groups A, B, C, D. When working on the Inline terminal, always disconnect the supply voltage. The Inline terminal must only be installed, started up, and maintained by qualified specialist personnel. Install the Inline terminals in a control cabinet or metal housing. The minimum requirement for both items is IP54 protection according to EN 60529. The Inline terminal must not be subject to mechanical strain and thermal loads, which exceed the limits specified in the product documentation. The Inline terminal must not be repaired by the user. Repairs may only be carried out by the manufacturer. The Inline terminal is to be replaced by an approved terminal of the same type. Only category 3G equipment may be connected to Inline terminals in zone 2. Observe all applicable standards and national safety and accident prevention regulations for installing and operating equipment. nt 1. UL approval 6. 7. Restrictions WARNING: Explosion hazard When using terminals in potentially explosive areas, observe the technical data and limit values specified in the corresponding documentation (user manual, data sheet, package slip). WARNING: Explosion hazard, Restrictions regarding the Inline system Please make sure that the maximum permissible current of 4 A flowing through potential jumpers UM and US (total current) is not exceeded when using the Inline terminals in potentially explosive areas. PHOENIX CONTACT 7 IB IL 24 DI 4 ... Programming data/ configuration data 8.1 Local bus (INTERBUS) 9 ID code BEhex (190dec) Length code 41hex Input address area 4 bits 0 bits Parameter channel (PCP) 0 bits Register length (bus) 4 bits 8.2 For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet. 9.1 Assignment of the terminal points to the IN process data (Byte.bit) view Module Byte.Bit 0.3 0.2 0.1 0.0 Terminal point (signal) Terminal point (+24 V) Terminal point (GND) LED 2.4 1.4 2.1 1.1 2.5 1.5 2.2 1.2 2.6 1.6 2.3 1.3 4 3 2 1 m Output address area Process data Other bus systems For the programming data/configuration data of other bus systems, please refer to the corresponding electronic device data sheet (e.g., GSD, EDS). on l in ec om po ne nt s. Status indicator co 8 5550_en_05 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 www.phoenixcontact.com 8
2692306 价格&库存

很抱歉,暂时无法提供与“2692306”相匹配的价格&库存,您可以联系我们找货

免费人工找货