ILB S3 24 DI8 DO4 AO2 INC-IN2
Inline Block IO module for sercos
Data sheet
8345_en_01
1
© PHOENIX CONTACT 2012-09-13
Description
The module is designed for use within a sercos network. It is
used for flexible control of two axes of motion regardless of
the drive hardware used. Using a ±10-V signal, two drive
amplifiers and using the incremental signal two rotary transducers can be connected to the module for position acquisition in combination with the digital I/Os for limit and home
position switches.
Features of the digital inputs
–
–
–
–
–
Connections for eight digital sensors
Connection of sensors in 2 or 3-wire technology
Maximum permissible load current per sensor: 250 mA
Maximum permissible load current from the sensor supply: 1 A (0.5 A per group)
Diagnostic and status indicators
sercos features
–
–
–
–
–
2 x Ethernet twisted pair according to 802.3u with auto
negotiation and auto crossing
100 Mbps transmission speed
I/O areas can be parameterized individually for each
channel
Supports sercos V1.1.2
sercos diagnostic LED
Features of the digital outputs
–
–
–
–
–
Connections for four digital actuators
Connection of actuators in 2 or 3-wire technology
Nominal current of each output: 0.5 A
Total current of all outputs: 4 A
Short-circuit-proof and overload-protected outputs
Make sure you always use the latest documentation.
It can be downloaded at www.phoenixcontact.net/catalog.
Here you will also find the current SDDML file.
This data sheet is only valid in association with the UM EN SERCOS SYS sercos system manual for I/O devices
and the "Assembly and removal of Inline Block IO modules" application note.
ILB S3 24 DI8 DO4 AO2 INC-IN2
Features of the analog outputs
–
–
–
–
–
–
Two analog signal outputs for the connection of voltage
signals
Connection of actuators in 2-wire technology
Voltage range: ±10 V
Resolution: 12 bits
Short-circuit-proof outputs
Parameterizable output values when the bus fails
Incremental encoder features
(for linear and rotary encoders)
Symmetrical incremental encoders (encoder with symmetrical data lines according to the RS 422 EIA standard):
– Encoder supply: 5 V DC or 24 V DC
– Connection method of the signals:
A and /A (inverted)
B and /B (inverted)
Z and /Z (inverted)
– Input frequency < 300 kHz
– Cable length up to 30 m
Asymmetrical incremental encoder (encoder with asymmetrical data cables, push pull 5 V to 24 V):
– Encoder supply: 5 V DC or 24 V DC
– Connection method of signals: A, B, Z
– Input frequency < 300 kHz
– Cable length up to 30 m
8345_en_01
PHOENIX CONTACT
2
ILB S3 24 DI8 DO4 AO2 INC-IN2
2
Table of contents
1
Description.................................................................................................................................. 1
2
Table of contents ........................................................................................................................ 3
3
Ordering data.............................................................................................................................. 4
4
Technical data ............................................................................................................................ 5
5
Internal basic circuit diagram ....................................................................................................10
6
Electrical isolation ......................................................................................................................11
7
Local diagnostic and status indicators .......................................................................................12
8
Connecting sercos, supply, analog sensors, and actuators ................................................................... 13
8.1
8.2
9
sercos connection ........................................................................................................................................ 13
Connecting the supply, actuators, and sensors............................................................................................ 14
Connection notes.......................................................................................................................16
10 sercos device profile ..................................................................................................................16
11 sercos ...................................................................................................................................................................... 16
11.1
11.2
sercos profiles classes, and function groups ................................................................................................ 16
Electronic rating plate................................................................................................................................... 17
12 Startup..................................................................................................................................................................... 17
13 IDN list, subdevice 1 ..................................................................................................................18
14 IDN list, subdevice 2 ..................................................................................................................25
15 Parameter descriptions..............................................................................................................31
8345_en_01
PHOENIX CONTACT
3
ILB S3 24 DI8 DO4 AO2 INC-IN2
3
Ordering data
Product
Description
Type
Inline Block IO module for sercos for the flexible control of two axes of motion ILB S3 24 DI8 DO4 AO2 INC-IN2
Order No.
Pcs. / Pkt.
2700174
1
Accessories: Ethernet
Description
Type
Order No.
Pcs. / Pkt.
Gray RJ45 plug set for linear cable
FL PLUG RJ45 GR/2
2744856
2
Green RJ45 plug set for crossed cable
FL PLUG RJ45 GN/2
2744571
2
Double sheathed Ethernet cable
FL CAT5 HEAVY
2744814
1
Flexible Ethernet cable
FL CAT5 FLEX
2744830
1
Assembly tool for RJ45 plugs
FL CRIMPTOOL
2744869
1
Matching dust protection covers and safety systems for RJ45 connections can be found in the product range from Reichle & DeMassari/Switzerland.
Accessories: Other
Description
Type
Order No.
Pcs. / Pkt.
End clamp for securing the module on the DIN rail for a horizontal mounting
position; to the right and left of the module
CLIPFIX 35
3022218
50
End clamp for securing the module on the DIN rail for a vertical mounting position; above and below the module
E/AL-NS 35
1201662
10
Documentation
Description
Type
Order No.
Pcs. / Pkt.
User manual: sercos system manual for I/O devices
UM EN SERCOS SYS
-
-
"Assembly and removal of Inline Block IO modules" application note
AH ILB INSTALLATION
9014931
-
8345_en_01
PHOENIX CONTACT
4
ILB S3 24 DI8 DO4 AO2 INC-IN2
4
Technical data
Housing dimensions
156
120
141
59
8345A002
Figure 1
Housing dimensions of the module (in mm)
General data
Weight
505 g (with connectors)
Operating mode
sercos process data mode
Transmission speed
100 Mbps
Connection method for sensors
2- and 3-wire technology (shielded)
Connection method for actuators
2-wire technology (shielded)
Connection data for Inline connectors
Connection method
Spring-cage terminals
Conductor cross section
0.08 mm2 ... 1.5 mm2 (solid or stranded), 28 - 16 AWG
Ambient conditions
Regulations
Developed according to VDE 0160 / EN 50178 / IEC 62103, UL 508
Ambient temperature (operation)
-25°C ... +60°C
Ambient temperature (storage/transport)
-25°C ... +85°C
Humidity (operation/storage/transport)
10% ... 95%, EN 61131-2
Air pressure (operation/storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protection
IP20
Class of protection
III, IEC 61140, EN 61140, VDE 0140-1
Air and creepage distances
According to DIN VDE 0110/IEC 60664, IEC 60664A,
DIN VDE 0160/EN 50178/IEC 62103
Housing material
Plastic, PVC-free, PBT, self-extinguishing (V0)
Pollution degree according to
EN 60664-1/IEC 60664-1, EN 61131-2/IEC 61131-2
2; condensation not permitted during operation
Surge voltage class
II
8345_en_01
PHOENIX CONTACT
5
ILB S3 24 DI8 DO4 AO2 INC-IN2
Interface
sercos interface
2 x sercos via RJ45 connector;
Shielding via parallel connection of R, C, and VDR
24 V module supply (communications power and sensor supply; UL and US)
Nominal value
24 V DC
Tolerance
-15%/+20% according to DIN EN 61131-2
Ripple
±5% according to DIN EN 61131-2
Permissible range
19.2 V DC to 30.0 V DC
Current consumption at UL
See “Supply of the module electronics with UL”
Current consumption at US
See “Supply of the senors with US at the digital inputs”
Current consumption from UA1/UA2
See “Supply of the digital outputs with UA1/UA2”
Protective measures for UL and US1/US2
Transient surge protection via arresters, serial protection against polarity reversal
Protective measures for UA1/UA2
Transient surge protection via arresters, serial protection against polarity reversal, channel-specific short-circuit protection
Connection
Via power connectors
Supply of the module logics with UL
Typical
Maximum
Current consumption at UL
750 mA
950 mA
With AO nominal load (IOUT = 20 mA with RL = 0 Ω) and connected incremental encoder signals (with supply of the increment encoder, 2 x 250 mA)
Supply of the sensors with US at the digital inputs
Typical
Maximum
Current consumption at US1/US2
-
1 A (0.5 A per group)
Supply of the digital outputs with UA1/UA2
Nominal value UA1/UA2
24 V DC
Current consumption at UA1/UA2
2A
Protection
Internal, channel-specific electronic fuse, short-circuit-proof
Digital inputs
Number
8
Connection method for sensors
2 and 3-wire technology
Input design
According to EN 61131-2 type 1
Definition of the switching thresholds
Maximum low-level voltage
ULmax < 5 V
Minimum high-level voltage
UHmin > 15 V
Common potentials
Sensor supply US, ground
Nominal input voltage UIN
24 V DC
Permissible range
-30 V < UIN < +30 V DC
Nominal input current at UIN
5 mA, typical
Current flow
Linear in the range 1 V < UIN < 30 V
Delay time
tON
tOFF
Approximately 50 µs typical, 100 µs maximum
Approximately 145 µs typical, 400 µs maximum
Permissible cable length to sensor
100 m
Use of AC sensors
AC sensors in the voltage range < UIN are limited in application
Error message to the higher-level control system
Missing sensor supply
Short circuit/overload of sensor supply
Digital outputs
Number
4
Connection method for actuators
2 or 3-wire technology
Nominal output voltage UOUT
24 V DC
Nominal current Inom per channel
0.5 A
8345_en_01
PHOENIX CONTACT
6
ILB S3 24 DI8 DO4 AO2 INC-IN2
Digital outputs [...]
Total current
2A
Protective measures
Channel-by-channel, electronic protection against short-circuit and overload
Delay time
tON
Approximately 40 µs typical, 200 µs maximum
tOFF
Approximately 150 µs typical, 400 µs maximum
Nominal load
Ohmic
48 Ω/12 W
Lamp
12 W
Inductive
12 VA (1.2 H, 50 Ω)
Switching frequency with nominal inductive load
0.5 Hz, maximum (1.2 H, 50 Ω)
Overload response
Auto restart
Response with inductive overload
Output may be damaged
Reverse voltage protection against short pulses
Protected against reverse voltages
Resistance to permanently applied reverse voltages
Protected against reverse voltages, permissible current 2 A, maximum
Response upon power down
The output follows the supply voltage without delay.
Limitation of the voltage induced on circuit interruption
-41.0 V
Single maximum energy in freewheeling
1 J, maximum
Protective circuit type
Integrated freewheeling circuit in the output chip
Overcurrent shutdown
At 0.7 A, minimum
Maximum output current when switched off
10 µA
When not loaded, a voltage can be measured even at an output that is not set.
Error message sent to the higher-level control system
Short circuit/overload of outputs
Analog outputs
Number
2
Voltage output range
±10 V
Maximum current per output (per channel)
5 mA
Protective measure
IB IL
Conversion time
75 µs
Resolution
12 bits (0.005 V/LSB)
Output load
Voltage output
RLmin = 2 kΩ
Transient protection
Yes, internally via arresters
Connection method of signals
2-wire termination; shielded, twisted pair cable
Short circuit protection
Voltage output
Yes, permanent electronic short-circuit protection
Enabling function
Yes, internal electronic
Optical indicators
5% output LED, channel-specific
Permissible cable lengths
Permissible cable lengths
30 m
The ambient conditions and the local conditions in the system can result in special requirements for the installation of cables. These must be
taken into consideration accordingly.
For the integration of shielded I/O cables in an equipotential bonding concept for the automation system, the following applies in principle:
Shielded analog I/O cables may only be connected directly to functional earth ground potential at a single point.This results in the prevention
of voltage equalization currents via the analog cable. Additional information is available on request.
8345_en_01
PHOENIX CONTACT
7
ILB S3 24 DI8 DO4 AO2 INC-IN2
Tolerances at TA = 25°C
AO output range
Absolute (typical)
±10V
±10 mV
Absolute (maximum)
Relative (typical)
Relative (maximum)
±15 mV
0.1%
±0.2%
The data contains the offset error, gain error, and linearity error. All percentage values refer to the relevant measuring range final value. Unless
stated otherwise, the values refer to nominal operation (nominal voltage US = UL = 24 V, preferred horizontal mounting position, "IB IL" format).
The maximum tolerance values represent the worst case measurement inaccuracy. They contain the theoretically maximum possible tolerances in the corresponding measuring ranges. In the same way, the theoretical maximum possible tolerances of the calibration and test
equipment have been taken into account.
Incremental encoder inputs
Number
2
Encoder signal
Two pulse trains (A and B, electrically shifted by 90°, leading or lagging depending on the direction of rotation) and one zero pulse (Z)
The corresponding red Ex LED (x = 1 to 4) lights up when the encoder cable is broken.
Connection method of signals
Shielded cable
Unshielded cables may lead to erroneous results in environments subject to heavy noise.
Encoder types
Symmetrical incremental encoders
Signal
5 V DC (symmetrical pulse train (RS-422) with transversal track)
Encoder supply
5 V DC or 24 V DC
Connection method of signals
A and /A, B and /B, Z and /Z
Signal voltage level
Differential signal (signal – inverted signal)
±0.5 V, minimum; ±6.0 V, maximum
Common mode range: signal–ground
-10 V ... +13.2 V
Input frequency
Up to 300 kHz
Cable length (for shielded cable)
< 30 m (to ensure conformance with EMC Directive)
Asymmetrical incremental encoders
Signal
5 V DC ... 24 V DC (asymmetrical pulse train without transversal track)
Encoder supply
5 V DC or 24 V DC
Connection method of signals
A, B, Z
Signal voltage level
Low ≤ 2.5 V, high ≥ 3.5 V (27 V, maximum)
Input frequency
Up to 300 kHz
Cable length (for shielded cable)
< 30 m (to ensure conformance with EMC Directive)
8345_en_01
PHOENIX CONTACT
8
ILB S3 24 DI8 DO4 AO2 INC-IN2
Electrical isolation/isolation of the voltage areas
Test distance
Test voltage
sercos/logic area
500 V AC, 50 Hz, 1 min
sercos/analog I/O
500 V AC, 50 Hz, 1 min
sercos/communications power UL
500 V AC, 50 Hz, 1 min
sercos/initiator supply US
500 V AC, 50 Hz, 1 min
sercos/functional earth ground
500 V AC, 50 Hz, 1 min
Incremental inputs/ I/O
500 V AC, 50 Hz, 1 min
Incremental inputs/functional earth ground
500 V AC, 50 Hz, 1 min
Incremental inputs/functional earth ground
500 V AC, 50 Hz, 1 min
Logic area/analog I/O
500 V AC, 50 Hz, 1 min
Logic area/communications power UL
500 V AC, 50 Hz, 1 min
Logic area/initiator supply US
500 V AC, 50 Hz, 1 min
Logic area/functional earth ground
500 V AC, 50 Hz, 1 min
Analog I/O/communications power UL
500 V AC, 50 Hz, 1 min
Analog I/O/initiator supply US
500 V AC, 50 Hz, 1 min
Analog I/O/functional earth ground
500 V AC, 50 Hz, 1 min
Communications power UL/initiator supply US
500 V AC, 50 Hz, 1 min
Communications power UL/functional earth ground
500 V AC, 50 Hz, 1 min
Initiator supply US/functional earth ground
500 V AC, 50 Hz, 1 min
Mechanical requirements
Vibration test sinusoidal vibrations according to
IEC 60068-2-6/EN 60068-2-6
5g load, 2.5 hours in each space direction
Shock test according to EN 60068-2-27/IEC 60068-2-27
30g load for 11 ms, half sinusoidal wave,
three shocks in each space direction and orientation
Broadband noise according to EN 60068-2-64/IEC 60068-2-64
0.78g load, 2.5 hours in each space direction
Conformance with EMC directive 2004/108/EC
Noise immunity test according to EN 61000-6-2
Electrostatic discharge (ESD)
EN 61000-4-2
IEC 61000-4-2
Criterion B
Electromagnetic fields
EN 61000-4-3
IEC 61000-4-3
Criterion A
Field strength: 10 V/m
Fast transients (burst)
EN 61000-4-4
IEC 61000-4-4
Criterion B
Remote bus: 2 kV
Voltage supply: 2 kV
I/O cables: 2 kV
4 kV contact discharge
8 kV air discharge
Criterion A
All interfaces: 1 kV
Surge voltage
EN 61000-4-5
IEC 61000-4-5
Criterion B
DC supply lines: ± 0.5 kV/± 0.5 kV
(symmetrical/asymmetrical)
Signal lines: ± 1 kV/± 1 kV
(symmetrical/asymmetrical)
Conducted interferences
EN 61000-4-6
IEC 61000-4-6
Criterion A
Test voltage 10 V
Noise emission test according to EN 61000-6-4
Radiated noise emission
EN 55011
Class A
Approvals
For the latest approvals, please visit www.phoenixcontact.net/catalog.
8345_en_01
PHOENIX CONTACT
9
ILB S3 24 DI8 DO4 AO2 INC-IN2
5
Internal basic circuit diagram
μP / FPGA
4x
5V
2x
4x
2x
24 V
5V
A
A
B
Z
24 V
B
Z
Imax=
0,5 A
Power
for INC
0,5 A
Imax=
0,5 A
24 V
US 2
IN 2
IN 1
OUT 1
OUT 2
UL
AOUT 1
UA 2
US 1 UA 1
Power
for INC
Imax=
A
/A
IN 1
5V
B
PWR 1
Figure 2
AGND
PWR 2
OUT 2
UI 2
GND
IN 3
OUT 1
/B
UI 1
FE
IN 2
Z
/Z
IN 3
IN 4
DI 1
DO 1
AO 1
INC 1
AOUT 2
0,5 A
24 V
A
/A
5V
B
/B
Z
/Z
AGND
Imax=
IN 4
DI 2
DO 2
AO 2
INC 2
Internal wiring of the terminal points
Input amplifier for current (I) or voltage (U)
U/I
Key:
Amplifier
Optocoupler
Power supply unit without electrical isolation
Switch
Power supply unit with electrical isolation
Transmitter
Electronic fuse
FPGA
MU X
FPGA (field programmable array)
Multiplexer
Digital/analog converter
U/I
8345_en_01
Universal output driver for current (I) or voltage (U) with integrated output shutdown
PHOENIX CONTACT
10
ILB S3 24 DI8 DO4 AO2 INC-IN2
6
Electrical isolation
INC encoder supply 24 V
(Power for INC)
INC encoder supply 5 V
(Power for INC)
INC encoder input
sercos
(5 V DC)
UL
(24 V DC)
Logic supply
INC encoder
(INC1 and INC2)
sercos
Logic part
(3,3 V DC / 2,5 V DC /1,2 V DC)
FPGA, switch
Analog periphery
(5 V DC /+- 15 V DC)
DAC, ADC, ...
Analog outputs
(A01 and A02)
U I1
U I2
US
(24 V DC)
Initiator supply
Initiator supply 24 V
UA1
UA2
(24 V DC)
Output supply
Digital inputs
Initiator
Digital outputs
Actuator
Figure 3
FE
Electrical isolation of the individual function areas
Shield
The shielding ground of the connected twisted
pair cables is electrically connected to FE. When
connecting network segments, avoid ground
loops, potential transfers, and voltage equalization currents via the braided shield.
NOTE: Electrostatic discharge
The module contains components that can be
damaged or destroyed by electrostatic discharge.
When handling the module, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and
IEC 61340-5-1.
Housing
Only personnel authorized by Phoenix Contact
are permitted to open the housing.
8345_en_01
PHOENIX CONTACT
11
ILB S3 24 DI8 DO4 AO2 INC-IN2
7
Local diagnostic and status indicators
Figure 4
Local diagnostic and status indicators
LED
LED
sercos
S3
Color/status
Green
ON:
Flashing at
4 Hz:
Red
ON:
Flashing at
4 Hz:
Red/green
Flashing at
4 Hz:
Orange
ON:
Flashing at
4 Hz:
OFF:
LNK1/2 Green
ON:
ACT1/2 Yellow
ON:
8345_en_01
Meaning
CP4 no error
Loop back activated
SIII C1D (Class 1 diagnostics)
Error on the module
Color/status
PWR1/PWR2
US1/2 Green
ON:
OFF:
UA1/2 Green
ON:
OFF:
UL
Green
ON:
OFF:
WARNING:
Loss of sercos telegram
CP0 ... CP3
Identification (bit 15 in device control)
Used for address assignment and
configuration errors
24 V communications power not
present or no sercos communication
Link1/2
The connection to a module via
Ethernet is established using port
1/2
Activity1/2
If the yellow LED is on, this indicates transmission or reception of
a telegram at port 1/2.
DI1 ... DI4
E
Red
ON:
OFF:
1 ... 4
Yellow
ON:
OFF:
DO1/DO2
E
Red
ON:
OFF:
1/2
Yellow
ON:
OFF:
Meaning
Sensor supply 1/2
Sensor supply 1/2 present
Sensor supply 1/2 not present
Actuator supply 1/2
Actuator supply 1/2 present
Actuator supply 1/2 not present
24 V communications power
24 V communications power present
24 V communications power not
present
Sensor supply error
Short-circuit or overload of one of
the sensor supplies
No sensor supply error
Status indicators for the inputs
Input active
Input not active
Output error message
Output short circuit or overload
No output error
Output status indicators
Output active
Output not active.
PHOENIX CONTACT
12
ILB S3 24 DI8 DO4 AO2 INC-IN2
O-S
ON:
OFF:
Orange
ON:
5V
Green
ON:
OFF:
INC1/INC2
UP
Yellow
ON and DN
LED OFF:
OFF and
DN LED
OFF:
DN
Yellow
ON and UP
LED OFF:
OFF and UP
LED OFF:
Z
Yellow
ON:
OFF:
8345_en_01
Meaning
8
Connecting sercos, supply, analog
sensors, and actuators
Status of the 24 V sensor supply
24 V sensor supply present
24 V sensor supply not present
Behavior of the analog output
in the event of an interruption
Behavior of the analog output when
the connection to the sercos master is interrupted: The default upon
delivery is parameterized.
Status of the 5 V sensor supply
5 V sensor supply present
5 V sensor supply not present.
8.1
sercos connection
State of position counter
Position counter counting upwards
Stopped
By default upon delivery, the Ethernet connections have
been set to auto negotiation with auto crossing.
The module can be connected with a 1:1 cable or a crossover cable.
Connect sercos to the module via an 8-pos. RJ45 connector. For the pin assignment of the female connector, please
refer to the following table:
Pin
1
2
3
4
5
6
7
8
Assignment
TD+ (transmit data +)
TD- (transmit data -)
RD+ (receive data +)
Reserved
Reserved
RD- (receive data -)
Reserved
Reserved
RJ45
State of position counter
Position counter counting upwards
Stopped
State of position counter
Z signal present
Z signal not active
Pin 4
Pin 3
Pin 2
Pin 1
Color/status
AO1/AO2
24 V
Green
Pin 8
Pin 7
Pin 6
Pin 5
LED
Figure 5
Pin assignment of RJ45 sockets
Figure 6
8-pos. RJ45 sockets
PHOENIX CONTACT
13
ILB S3 24 DI8 DO4 AO2 INC-IN2
Observe bending radii
Shield
The housing dimensions specified under “General data” on page 5 refer to the bus coupler with
Inline connectors without Ethernet connection.
When installing the bus coupler in a control box
observe the bending radii of the Ethernet cables
and the connectors used.If required, use angled
RJ45 connectors to maintain these bending radii.
The shielding ground of the connected twisted
pair cables is electrically connected to the socket.
When connecting network segments, avoid
ground loops, potential transfers, and voltage
equalization currents via the braided shield.
8.2
Connecting the supply, actuators, and sensors
Figure 7
Terminal point assignment of the connectors
Power is supplied via the PWR1 and PWR2 terminals. Sensors and actuators of axis1 or I/O group1 are supplied via PWR1,
and those of axis2 or I/O group2 are supplied via PWR2.
Inline power connector 1 (PWR1)
Terminal
Assignment
point
1.1
24 V sensor supply US1
1.2
24 V communications power UL
1.3
GND
1.4
FE
8345_en_01
Terminal
point
2.1
2.2
2.3
2.4
Assignment
Actuator supply UA1
24 V communications power UL
GND
FE
PHOENIX CONTACT
14
ILB S3 24 DI8 DO4 AO2 INC-IN2
Inline power connector 2 (PWR2)
Terminal
Assignment
point
1.1
24 V sensor supply US2
1.2
24 V communications power UL
1.3
GND
1.4
FE
Inline connector 3 and Inline connector 7 (DI1 and DI2)
Terminal
Assignment
point
1.1
Signal input 1 (IN 1)
1.2
Sensor voltage US1/US2
for 2 and 3-wire termination
1.3
Ground contact (GND)
for 3-wire termination
1.4
Signal input 3 (IN 3)
1.5
Sensor voltage US1/US2
for 2 and 3-wire termination
1.6
Ground contact (GND)
for 3-wire termination
Terminal
point
2.1
2.2
2.3
2.4
Assignment
Terminal
point
2.1
2.2
Assignment
2.3
2.4
2.5
2.6
Inline connector 4 and Inline connector 8 (DO1 and DO2)
Terminal
Assignment
Terminal
point
point
1.1
Signal output 1 (OUT1)
2.1
1.2
Not used
2.2
1.3
Ground contact (GND)
2.3
for 3-wire termination
1.4
FE
2.4
Inline connector 5 and Inline connector 9 (AO1 and AO2)
Terminal
Assignment
Terminal
point
point
1.1
Analog output (AOUT1)
2.1
1.2
Not used
2.2
1.3
AGND
2.3
1.4
FE
2.4
Inline connector 6 and Inline connector 10 (INC1 and INC2)
Terminal
Assignment
Terminal
point
point
1.1
A+
2.1
1.2
B+
2.2
1.3
Z+
2.3
1.4
FE
2.4
8345_en_01
Actuator supply UA2
24 V communications power UL
GND
FE
Signal input 2 (IN 2)
Sensor voltage US1/US2
for 2 and 3-wire termination
Ground contact (GND)
for 3-wire termination
Signal input 4 (IN 4)
Sensor voltage US1/US2
for 2 and 3-wire termination
Ground contact (GND)
for 3-wire termination
Assignment
Signal output 2 (OUT2)
Not used
Ground contact (GND)
for 3-wire termination
FE
Assignment
24 V encoder supply
5 V encoder supply
GND
FE
Assignment
ABZFE
PHOENIX CONTACT
15
ILB S3 24 DI8 DO4 AO2 INC-IN2
9
Connection notes
sercos
The module has an FE spring (metal clip) on the
bottom of the electronics base. This spring establishes an electrical connection to the DIN rail. Use
grounding terminals to connect the DIN rail to protective earth ground. The module is grounded
when it is snapped onto the DIN rail.
To ensure reliable functional earth grounding
of the module even when the DIN rail is dirty
or the metal clip is damaged, always ground
the module additionally via the FE terminal
point.
Up to a sercos cycle time of 500 µs, all inputs and outputs
are detected or output clock-synchronously to the sercos
cycle.
With sercos cycle times of less than 500 µs, the I/O update
cycle time is 500 µs.
Always connect the analog sensors using shielded, twisted pair cables.
Connect the shielding to the module using the
shield connection clamp. The clamp connects the
shield to FE on the module side. Avoid connection to FE from both sides.
sercos device profile:
(GDP: Generic Device Profile)
The module is supplied with a shield connector
and a standard connector for each input channel.
The shield connection can be used for the standard signal (current/voltage).
10
11
sercos device profile
The device consists of two subdevices. Each subdevice has
an I/O resource (FSP-IO) and a drive resource (FSP-Drive).
The module allows a maximum of two real-time connections
(IDN/S-0-1050.0.x and IDN/S-0-1050.3.x).
11.1
sercos profiles classes, and function groups
The following sercos profiles and classes according to the
specification version V1.1.2 are implemented in the module:
Basic device profile (GDP_Basic)
– Diagnostics (FG_Diagnosis)
– Administration (FG_Administration)
– Device identification (FG_Identification)
sercos communication profile
(SCP: Communication Profiles)
–
–
–
–
–
–
–
Variable configuration (SCP_VarCfg)
Synchronizsation (SCP_Sync)
Watchdog (SCP_WD)
Diagnostics (SCP_Diag)
Unified Communication Channel (SCP_NRT)
GDP basic profile (GDP_Basic)
Electronic rating plate (FG Identification)
sercos function profile
(FSP: Function-Specific Profile IO)
–
–
Figure 8
8345_en_01
I/O profile (FSP_IO)
Drive profile (FSP-Drive)
Device profile
PHOENIX CONTACT
16
ILB S3 24 DI8 DO4 AO2 INC-IN2
11.2
Electronic rating plate
12
Startup
The electronic rating place includes the following IDNs.
Delivery state
IDN
Contents
S-0-1300.0.01
Component
Name
PxC axis IO module
S-0-1300.0.02
VendorName
„Phoenix Contact”
S-0-1300.0.03
VendorCode
„200“
S-0-1300.0.04
DeviceName
„ILB S3 24 DI8 DO4 AO2 INC-IN2”
S-0-1300.0.05
VendorDevice ID
„2700174”
S-0-1300.0.06
Connected to
0
sub-deviceModul
S-0-1300.0.07
Function
Revision
1
S-0-1300.0.08
Hardware
Revision
V01R02
S-0-1300.0.09
SoftwareRevision V01R27.Nf
S-0-1300.0.10
Firmware loader
Revision
V01R01
S-0-1300.0.11
Order number
„2700174”
S-0-1300.0.12
Serial number
“171949-xxxxx“, xxxxx = consecutive number, starting with 00001
S-0-1300.0.13
Manfacturing
date
z.B. „2009-06-15T12:00:30Z“
sercos address = 55
S-0-1300.0.14
QS date
Date of final test after production
S-0-1300.0.20
Operational
hours
Operating hours counters
S-0-1300.0.21
Service date
Service date (e.g. firmware update)
S-0-1300.0.22
Calibration date
Calibration date
S-0-1300.0.23
Calibration due
date
Date of next calibration
S-0-1300.0.128
FPGA version identification
S-0-1300.0.129
Identification of the processor kernel
S-0-1300.0.130
Time stamp of FPGA creation
S-0-1300.0.131
Identification of the configuration
data record stored in the flash
S-0-1300.0.132
Checksum of the firmware
S-0-1300.0.133
Last boot filename assigned via
BootP
S-0-1300.0.134
Part of the configuration data saved
in the flash
S-0-1300.0.135
Internal version information of the S
stack used
S-0-1300.0.136
Build string with SVN revision and
date/clock
8345_en_01
By default upon delivery, the following features are available:
Reconfiguration button
The reconfiguration button is currently not supported.
sercos address assignment
–
–
–
There is no switch for setting the sercos address.
The module supports automatic address assignment
for the sercos address.
The sercos address is stored retentively.
For additional information about automatic address assignment, please refer to the sercos
master documentation.
PHOENIX CONTACT
17
ILB S3 24 DI8 DO4 AO2 INC-IN2
13
IDN list, subdevice 1
The following table lists all implemented sercos parameters (S parameters) with important features.
IDN
Name
Attributes
Default value
Unit
S-0-0011.0.0
Class 1 diagnostic (C1D)
0x70010001
S-0-0012.0.0
Class 2 diagnostic (C2D)
0x70010001
S-0-0014.0.0
Interface status
0x70010001
S-0-0017.0.0
IDN-list of all operation data
0x70560001
S-0-0021.0.0
IDN-list of invalid operation data for CP2
0x560001
S-0-0022.0.0
IDN-list of invalid operation data for CP3
0x560001
S-0-0025.0.0
IDN-list of all procedure commands
0x70560001
S-0-0032.0.0
Primary operation mode
0x10001
S-0-0033.0.0
Secondary operation mode 1
0x10001
S-0-0036.0.0
Velocity command value
0x1220001
rpm
S-0-0037.0.0
Additive velocity command value
0x1220001
rpm
S-0-0038.0.0
Positive velocity limit value
0x1220001
rpm
S-0-0039.0.0
Negative velocity limit value
0x1220001
rpm
S-0-0040.0.0
Velocity feedback value 1
0x1220001
rpm
S-0-0041.0.0
Homing velocity
0x1220001
rpm
S-0-0042.0.0
Homing acceleration
0x120001
--
S-0-0043.0.0
Velocity polarity parameter
0x40010001
S-0-0044.0.0
Velocity data scaling type
0x40010001
S-0-0045.0.0
Velocity data scaling factor
0x40110001
S-0-0046.0.0
Velocity data scaling exponent
0x40210001
S-0-0047.0.0
Position command value
0x6220001
deg
S-0-0051.0.0
Position feedback value 1 (motor feedback)
0x76220001
deg
S-0-0053.0.0
Position feedback value 2 (external feedback)
0x76220001
deg
S-0-0060.0.0
Position switch point 1
0x6220001
deg
S-0-0061.0.0
Position switch point 2
0x6220001
deg
S-0-0062.0.0
Position switch point 3
0x6220001
deg
S-0-0063.0.0
Position switch point 4
0x6220001
deg
S-0-0064.0.0
Position switch point 5
0x6220001
deg
S-0-0065.0.0
Position switch point 6
0x6220001
deg
S-0-0066.0.0
Position switch point 7
0x6220001
deg
S-0-0067.0.0
Position switch point 8
0x6220001
deg
S-0-0068.0.0
Position switch point 9
0x6220001
deg
S-0-0069.0.0
Position switch point 10
0x6220001
deg
S-0-0070.0.0
Position switch point 11
0x6220001
deg
S-0-0071.0.0
Position switch point 12
0x6220001
deg
S-0-0072.0.0
Position switch point 13
0x6220001
deg
S-0-0073.0.0
Position switch point 14
0x6220001
deg
S-0-0074.0.0
Position switch point 15
0x6220001
deg
S-0-0075.0.0
Position switch point 16
0x6220001
deg
S-0-0076.0.0
Position data scaling type
0x40010001
S-0-0077.0.0
Linear position data scaling type
0x40110001
S-0-0078.0.0
Linear position data scaling exponent
0x40210001
S-0-0079.0.0
Rotational position resolution
0x40120001
S-0-0080.0.0
Torque command value
0x210001
--
S-0-0081.0.0
Additive torque command value
0x210001
--
S-0-0082.0.0
Positive torque limit value
0x210001
--
S-0-0083.0.0
Negative torque limit value
0x210001
--
S-0-0084.0.0
Torque feedback value
0x210001
--
8345_en_01
Minimum
Maximum
0
0
1
1
1
PHOENIX CONTACT
18
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
Minimum
Maximum
S-0-0086.0.0
Torque/force data scaling type
0x40010001
S-0-0095.0.0
Diagnostic message
0x70440001
S-0-0099.0.0
Reset class 1 diagnostic
0x90001
S-0-0100.0.0
Velocity loop proportional gain
0x120001
0
0
S-0-0101.0.0
Velocity loop integral action time
0x1110001
S-0-0102.0.0
Velocity loop differential time
0x110001
ms
S-0-0103.0.0
Modulo value
0x120001
--
S-0-0104.0.0
Position loop KV-factor
0x110001
m/min
S-0-0105.0.0
Position loop integral action time
0x110001
ms
S-0-0106.0.0
Current loop proportional gain 1
0x120001
S-0-0107.0.0
Current loop integral action time 1
0x110001
µs
S-0-0108.0.0
Feedrate override
0x110001
%
S-0-0109.0.0
Motor peak current
0x3120001
A
S-0-0113.0.0
Maximum motor speed
0x4120001
1/min
S-0-0115.0.0
Position feedback 2 type
0x10001
S-0-0116.0.0
Resolution of feedback 1
0x60120001
S-0-0117.0.0
Resolution of feedback 2
0x60120001
S-0-0127.0.0
CP3 transition check
0x60090001
S-0-0128.0.0
0
0
CP4 transition check
0x50090001
0
0
S-0-0130.0.0
Probe value 1 positive edge
0x6220001
deg
S-0-0131.0.0
Probe value 1 negative edge
0x6220001
deg
S-0-0132.0.0
Probe value 2 positive edge
0x6220001
deg
S-0-0133.0.0
Probe value 2 negative edge
0x6220001
deg
S-0-0134.0.0
Drive control
0x310001
S-0-0135.0.0
Drive status
0x70310001
S-0-0146.0.0
Control unit controlled homing procedure command
0x90001
S-0-0147.0.0
Homing parameter
0x10001
S-0-0148.0.0
Drive controlled homing procedure command
0x90001
S-0-0169.0.0
Probe control
0x10001
S-0-0170.0.0
Probing cycle procedure command
0x90001
S-0-0187.0.0
IDN-list of configurable data in the AT
0x70560001
ID
S-0-0188.0.0
IDN-list of configurable data in the MDT
0x70560001
ID
S-0-0192.0.0
IDN-List of all backup operation data
0x70560001
S-0-0193.0.0
Positioning jerk
0x220001
S-0-0206.0.0
Drive on delay time
0x1110001
ms
S-0-0207.0.0
Drive off delay time
0x1110001
ms
S-0-0256.0.0
Multiplication factor 1
0x120001
S-0-0257.0.0
Multiplication factor 2
0x120001
S-0-0258.0.0
Target position
0x6220001
deg
S-0-0259.0.0
Positioning velocity
0x1220001
rpm
S-0-0260.0.0
Positioning acceleration
0x220001
--
S-0-0264.0.0
Backup working memory procedure command
0x60090001
S-0-0267.0.0
Password
0x60440001
S-0-0273.0.0
Maximum drive off delay time
0x1110001
S-0-0277.0.0
Position feedback 1 type
0x10001
S-0-0279.0.0
List of password protected data
0x60560001
S-0-0292.0.0
List of supported operation modes
0x70350001
S-0-0295.0.0
Drive enable delay time
0x1110001
S-0-0304.0.0
Real-time status bit 1
0x10001
S-0-0305.0.0
Allocation of real-time status bit 1
0x520001
S-0-0306.0.0
Real-time status bit 2
0x10001
S-0-0307.0.0
Allocation of real-time status bit 2
0x520001
8345_en_01
Default value
Unit
ms
--
PW71949
ms
ms
PHOENIX CONTACT
19
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
Default value
Unit
Minimum
Maximum
S-0-0359.0.0
Positioning deceleration
0x220001
S-0-0390.0.0
Diagnostic Number
0x70320001
S-0-0393.0.0
Command value mode
0x10001
S-0-0400.0.0
Home switch
0x10001
S-0-0405.0.0
Probe 1 enable
0x10001
S-0-0406.0.0
Probe 2 enable
0x10001
S-0-0409.0.0
Probe 1 positive latched
0x110001
S-0-0410.0.0
Probe 1 negative latched
0x110001
S-0-0411.0.0
Probe 2 positive latched
0x110001
S-0-0412.0.0
Probe 2 negative latched
0x110001
S-0-0415.0.0
Bit number allocation of real-time status bit 1
S-0-0416.0.0
Bit number allocation of real-time status bit 2
0x110001
0
63
0x110001
0
S-0-0417.0.0
Positioning velocity threshold in modulo mode
0x1120001
rpm
63
S-0-0418.0.0
Target position window in modulo mode
0x6120001
deg
S-0-0426.0.0
Measuring data allocation 1
0x520001
250000
65000000
65000000
--
S-0-0427.0.0
Measuring data allocation 2
0x520001
S-0-0428.0.0
IDN list of configurable measuring data
0x70560001
S-0-0430.0.0
Active target position
0x6220001
S-0-0437.0.0
Positioning status
0x10001
S-0-0440.0.0
Marker position feedback 1
0x6220001
deg
S-0-0441.0.0
Marker position feedback 2
0x6220001
deg
S-0-0442.0.0
Counter marker position feedback 1
0x110001
S-0-0443.0.0
Counter marker position feedback 2
0x110001
S-0-1000.0.0
SCP Type & Version
0x70350001
S-0-1002.0.0
Cycle time (tScyc)
0x63120001
S-0-1003.0.0
Allowed MST losses in CP3/CP4
0x60120001
S-0-1005.0.0
Minimum feedback processing time (t5)
0x73120001
ns
S-0-1006.0.0
AT transmission starting time (t1)
0x63120001
ns
0
S-0-1007.0.0
Feedback acquisition capture point (t4)
0x63120001
ns
0
65000000
S-0-1008.0.0
Command value valid time (t3)
0x63120001
ns
0
65000000
S-0-1009.0.0
Device Control
0x60310001
S-0-1010.0.0
Lengths of MDT
0x60150001
S-0-1011.0.0
Device Status offset in AT
0x60310001
deg
0x0201
0x0301
0x0401
0x0501
0x0A01
ns
S-0-1012.0.0
Lengths of ATs
0x60150001
S-0-1013.0.0
SVC offset in MDT
0x60310001
S-0-1014.0.0
SVC offset in AT
0x63310001
S-0-1015.0.0
Ring delay
0x3120001
ns
S-0-1016.0.0
Slave delay (P/S)
0x73160001
ns
S-0-1017.0.0
NRC transmission time
0x63160001
S-0-1019.0.0
MAC address
0x70340001
00-60-34-xx-xx-xx
S-0-1020.0.0
IP address
0x140001
149.208.18.209
S-0-1021.0.0
Subnet mask
0x140001
255.255.0.0
S-0-1022.0.0
Gateway address
0x140001
0.0.0.0
S-0-1023.0.0
SYNC jitter
0x63120001
S-0-1024.0.0
SYNC delay measuring procedure command
0x90001
S-0-1026.0.0
Version of communication hardware
0x70440001
1048575
ns
ns
63750
0
0
S-0-1027.0.1
Maximum transmission unit sent within the NRT channel 0x60110001
46
1500
S-0-1027.0.2
Maximum transm
0x70110001
46
1500
S-0-1028.0.0
Error counter MST P/S
0x110001
8345_en_01
PHOENIX CONTACT
20
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
S-0-1035.0.0
Error counter Port1 & Port2
0x320001
S-0-1040.0.0
sercos address
0x110001
S-0-1041.0.0
AT Command value valid time (t9)
0x63120001
S-0-1044.0.0
Device Control
0x70310001
S-0-1045.0.0
Device Status
0x70310001
S-0-1046.0.0
List of sercos addresses in device
0x70150001
S-0-1050.0.1
Configuration of The Connection
0x60310001
S-0-1050.0.2
Connection Number
0x60110001
S-0-1050.0.3
Telegram Assignment
0x60310001
S-0-1050.0.4
Max. Length of Connection
0x70110001
S-0-1050.0.5
Actual Length of Connection
0x70110001
S-0-1050.0.6
Configuration List
0x60560001
S-0-1050.0.8
Connection Control (C-Con)
0x10001
S-0-1050.0.10
Producer Cycle Time
0x63120001
S-0-1050.0.11
Allowed Data Losses
0x60110001
S-0-1050.0.12
Error Counter Data Losses
0x70110001
S-0-1050.0.20
IDN allocation of real-time bit
0x560001
S-0-1050.0.21
Bit allocation of real-time bit
0x150001
S-0-1050.1.1
Configuration Of The Connection
0x60310001
S-0-1050.1.2
Connection Number
0x60110001
S-0-1050.1.3
Telegram Assignment
0x60310001
S-0-1050.1.4
Max. Length of Connection
0x70110001
S-0-1050.1.5
Actual Length of Connection
0x70110001
S-0-1050.1.6
Configuration List
0x60560001
S-0-1050.1.8
Connection Control (C-Con)
0x10001
S-0-1050.1.10
Producer Cycle Time
0x63120001
S-0-1050.1.11
Allowed Data Losses
0x60110001
S-0-1050.1.12
Error Counter Data Losses
0x70110001
S-0-1050.1.20
IDN allocation of real-time bit
0x560001
S-0-1050.1.21
Bit allocation of real-time bit
0x150001
S-0-1050.2.1
Configuration of the Connection
0x60310001
S-0-1050.2.2
Connection Number
0x60110001
S-0-1050.2.3
Telegram Assignment
0x60310001
S-0-1050.2.4
Max. Length of Connection
0x70110001
S-0-1050.2.5
Actual Length of Connection
0x70110001
S-0-1050.2.6
Configuration List
0x60560001
S-0-1050.2.8
Connection Control (C-Con)
0x10001
S-0-1050.2.10
Producer Cycle Time
0x63120001
S-0-1050.2.11
Allowed Data Losses
0x60110001
S-0-1050.2.12
Error Counter Data Losses
0x70110001
S-0-1050.2.20
IDN allocation of real-time bit
0x560001
S-0-1050.2.21
Bit allocation of real-time bit
0x150001
S-0-1050.3.1
Configuration of the Connection
0x60310001
S-0-1050.3.2
Connection Number
0x60110001
S-0-1050.3.3
Telegram Assignment
0x60310001
S-0-1050.3.4
Max. Length of Connection
0x70110001
S-0-1050.3.5
Actual Length of Connection
0x70110001
S-0-1050.3.6
Configuration List
0x60560001
S-0-1050.3.8
Connection Control (C-Con)
0x10001
S-0-1050.3.10
Producer Cycle Time
0x63120001
S-0-1050.3.11
Allowed Data Losses
0x60110001
S-0-1050.3.12
Error Counter Data Losses
0x70110001
8345_en_01
Default value
Unit
Minimum
0
511
µs
0
65000000
0
65535
2
1484
55
ns
ns
ns
ns
Maximum
1000000
65000000
1
65535
0
65535
2
1484
1000000
65000000
1
65535
0
65535
2
1484
1000000
65000000
1
65535
0
65535
2
1484
1000000
65000000
1
65535
PHOENIX CONTACT
21
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
S-0-1050.3.20
IDN allocation of real-time bit
0x560001
S-0-1050.3.21
Bit allocation of real-time bit
0x150001
Default value
Unit
Minimum
Maximum
S-0-1051.0.0
Image of connection setups
0x70350001
S-0-1300.0.1
Component Name
0x70440001
?
S-0-1300.0.2
Vendor name
0x70440001
?
S-0-1300.0.3
Vendor Code
0x70110001
?
S-0-1300.0.4
Device Name
0x70440001
?
S-0-1300.0.5
Device ID
0x70440001
?
S-0-1300.0.6
Connected to sub-device
0x70110001
?
0
511
S-0-1300.0.7
Function Revision
0x70110001
?
0
9999
S-0-1300.0.8
Hardware Revision
0x70440001
?
S-0-1300.0.9
Software Revision
0x70440001
?
S-0-1300.0.10
Firmware Loader Revision
0x70440001
?
S-0-1300.0.11
Order number
0x70440001
?
S-0-1300.0.12
Serial number
0x70440001
?
S-0-1300.0.13
Manufacturing Date
0x70440001
S-0-1300.0.20
Operational Hours
0x70120001
S-0-1300.0.128
FPGA register BOARD-ID
0x70310001
S-0-1300.0.129
FPGA register SYSID-ID
0x70120001
S-0-1300.0.130
FPGA register SYSID-Timestamp
0x70120001
S-0-1300.0.131
Configuration data-set identification
0x70440001
S-0-1300.0.132
Firmware checksum
0x70310001
S-0-1300.0.133
Firmware filename
0x70440001
S-0-1300.0.134
INI block content
0x70440001
S-0-1300.0.135
Slave communication stack
0x70440001
S-0-1301.0.0
List of GDP Classes & Version
0x70350001
0x0101
S-0-1302.0.1
FSP Type & Version
0x70320001
0x00010001
S-0-1302.0.2
Function Groups
0x70560001
S-0-1500.0.0
S-0-1504.1.0
S-0-1505.1.0
S-0-1515.1.0
S-0-1504.2.0
S-0-1505.2.0
S-0-1515.2.0
S-0-1504.3.0
S-0-1505.3.0
S-0-1515.3.0
S-0-1504.4.0
S-0-1505.4.0
S-0-1515.4.0
S-0-1302.0.3
Application Type
0x440001
Axis
S-0-1303.0.1
List of Diagnostic Numbers
0x360001
S-0-1303.0.3
List of faulty Function Groups
0x560001
S-0-1303.0.4
List of additional diag. Infos
0x50001
S-0-1500.0.1
IO Control
0x10001
S-0-1500.0.2
IO Status
0x10001
S-0-1500.0.3
Module Type Code
0x70370001
S-0-1500.0.5
Container OutputData
0x350001
S-0-1500.0.9
Container InputData
0x350001
S-0-1500.0.19
Parameter Channel Receive
0x70340001
S-0-1500.0.20
Parameter Channel Transmit
0x60340001
S-0-1500.0.32
IO Diagnosis Message
0xF1
S-0-1502.0.1
Name of IO_FG
0x440001
S-0-1502.0.2
Configuration of IO_FG
0x60010001
S-0-1502.0.3
Channel Quantity PDOUT
0x70110001
8345_en_01
h
0
?
2
PHOENIX CONTACT
22
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
Default value
Unit
S-0-1502.0.4
Channel Size PDOUT
0x70110001
1
S-0-1502.0.5
PDOUT
0x10001
S-0-1502.0.19
Parameter Channel Receive
0x70340001
S-0-1502.0.20
Parameter Channel Transmit
0x70340001
S-0-1502.0.22
Fall Back Value Output
0x10001
S-0-1502.0.23
Min. Delay Time
0x70120001
ns
S-0-1502.0.24
Max. Delay Time
0x70120001
ns
S-0-1503.0.1
Name of IO_FG
0x440001
S-0-1503.0.2
Configuration of IO_FG
0x60010001
S-0-1503.0.7
Channel Quantity PDIN
0x70110001
4
S-0-1503.0.8
Channel Size PDIN
0x70110001
1
S-0-1503.0.9
PDIN
0x70010001
S-0-1503.0.19
Parameter Channel Receive
0x70340001
S-0-1503.0.20
Parameter Channel Transmit
0x70340001
S-0-1503.0.23
Min. Delay Time
0x70120001
ns
S-0-1503.0.24
Max. Delay Time
0x70120001
ns
S-0-1504.0.1
Name of IO_FG
0x440001
S-0-1504.0.2
Configuration of IO_FG
0x60010001
S-0-1504.0.3
Channel Quantity PDOUT
0x70110001
1
S-0-1504.0.4
Channel Size PDOUT
0x70110001
16
S-0-1504.0.5
PDOUT
0x110001
S-0-1504.0.19
Parameter Channel Receive
0x70340001
S-0-1504.0.20
Parameter Channel Transmit
0x70340001
S-0-1504.0.22
Fall Back Value Output
0x110001
S-0-1504.0.23
Min. Delay Time
0x70120001
ns
S-0-1504.0.24
Max. Delay Time
0x70120001
ns
S-0-1506.0.1
Name of IO_FG
0x440001
S-0-1506.0.2
Configuration of IO_FG
0x60010001
S-0-1506.0.7
Channel Quantity PDIN
0x70110001
S-0-1506.0.8
Channel Size PDIN
0x70110001
S-0-1506.0.9
PDIN
0x70120001
S-0-1506.0.19
Parameter Channel Receive
0x70340001
S-0-1506.0.20
Parameter Channel Transmit
0x70340001
S-0-1506.0.23
Min. Delay Time
0x70120001
ns
S-0-1506.0.24
Max. Delay Time
0x70120001
ns
P-0-1002.0.1
Reference Input Select
0x20001
P-0-1002.0.2
Overtemperature Input Select
0x20001
P-0-1002.0.3
Inverter Error Input Select
0x20001
P-0-1003.1.1
Logic Position-Switch S-0-0060 for Output 1
0x20001
P-0-1003.1.2
Logic Position-Switch S-0-0061 for Output 1
0x20001
P-0-1003.1.3
Logic Position-Switch S-0-0062 for Output 1
0x20001
P-0-1003.1.4
Logic Position-Switch S-0-0063 for Output 1
0x20001
P-0-1003.1.5
Logic Position-Switch S-0-0064 for Output 1
0x20001
P-0-1003.1.6
Logic Position-Switch S-0-0065 for Output 1
0x20001
P-0-1003.1.7
Logic Position-Switch S-0-0066 for Output 1
0x20001
P-0-1003.1.8
Logic Position-Switch S-0-0067 for Output 1
0x20001
P-0-1003.1.9
Logic Position-Switch S-0-0068 for Output 1
0x20001
P-0-1003.1.10
Logic Position-Switch S-0-0069 for Output 1
0x20001
P-0-1003.1.11
Logic Position-Switch S-0-0070 for Output 1
0x20001
P-0-1003.1.12
Logic Position-Switch S-0-0071 for Output 1
0x20001
P-0-1003.1.13
Logic Position-Switch S-0-0072 for Output 1
0x20001
P-0-1003.1.14
Logic Position-Switch S-0-0073 for Output 1
0x20001
8345_en_01
Minimum
Maximum
PHOENIX CONTACT
23
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
P-0-1003.1.15
Logic Position-Switch S-0-0074 for Output 1
0x20001
P-0-1003.1.16
Logic Position-Switch S-0-0075 for Output 1
0x20001
P-0-1003.2.1
Logic Position-Switch S-0-0060 for Output 2
0x20001
P-0-1003.2.2
Logic Position-Switch S-0-0061 for Output 2
0x20001
P-0-1003.2.3
Logic Position-Switch S-0-0062 for Output 2
0x20001
P-0-1003.2.4
Logic Position-Switch S-0-0063 for Output 2
0x20001
P-0-1003.2.5
Logic Position-Switch S-0-0064 for Output 2
0x20001
P-0-1003.2.6
Logic Position-Switch S-0-0065 for Output 2
0x20001
P-0-1003.2.7
Logic Position-Switch S-0-0066 for Output 2
0x20001
P-0-1003.2.8
Logic Position-Switch S-0-0067 for Output 2
0x20001
P-0-1003.2.9
Logic Position-Switch S-0-0068 for Output 2
0x20001
P-0-1003.2.10
Logic Position-Switch S-0-0069 for Output 2
0x20001
P-0-1003.2.11
Logic Position-Switch S-0-0070 for Output 2
0x20001
P-0-1003.2.12
Logic Position-Switch S-0-0071 for Output 2
0x20001
P-0-1003.2.13
Logic Position-Switch S-0-0072 for Output 2
0x20001
P-0-1003.2.14
Logic Position-Switch S-0-0073 for Output 2
0x20001
P-0-1003.2.15
Logic Position-Switch S-0-0074 for Output 2
0x20001
P-0-1003.2.16
Logic Position-Switch S-0-0075 for Output 2
0x20001
P-0-1004.0.1
Select Analogue Output Signal
0x20001
P-0-1004.0.4
Analogue Output Value
0x72220001
P-0-1005.1.1
Select Digital Output Signal 1
0x20001
P-0-1005.2.1
Select Digital Output Signal 2
0x20001
8345_en_01
Default value
Unit
Minimum
Maximum
Volt
PHOENIX CONTACT
24
ILB S3 24 DI8 DO4 AO2 INC-IN2
14
IDN list, subdevice 2
The following table lists all implemented sercos parameters (S parameters) with important features.
IDN
Name
Attributes
S-0-0011.0.0
Class 1 diagnostic (C1D)
0x70010001
S-0-0012.0.0
Class 2 diagnostic (C2D)
0x70010001
S-0-0014.0.0
Interface status
0x70010001
Unit
S-0-0017.0.0
IDN-list of all operation data
0x60560001
S-0-0021.0.0
IDN-list of invalid operation data for CP2
0x560001
S-0-0022.0.0
IDN-list of invalid operation data for CP3
0x560001
S-0-0025.0.0
IDN-list of all procedure commands
0x70560001
S-0-0032.0.0
Primary operation mode
0x10001
S-0-0033.0.0
Secondary operation mode 1
0x10001
S-0-0036.0.0
Velocity command value
0x1220001
rpm
S-0-0037.0.0
Additive velocity command value
0x1220001
rpm
S-0-0038.0.0
Positive velocity limit value
0x1220001
rpm
S-0-0039.0.0
Negative velocity limit value
0x1220001
rpm
S-0-0040.0.0
Velocity feedback value 1
0x1220001
rpm
S-0-0041.0.0
Homing velocity
0x1220001
rpm
S-0-0042.0.0
Homing acceleration
0x120001
--
S-0-0043.0.0
Velocity polarity parameter
0x40010001
S-0-0044.0.0
Velocity data scaling type
0x40010001
S-0-0045.0.0
Velocity data scaling factor
0x40110001
S-0-0046.0.0
Velocity data scaling exponent
0x40210001
Maximum
0
0
1
S-0-0047.0.0
Position command value
0x6220001
deg
S-0-0051.0.0
Position feedback value 1 (motor feedback)
0x76220001
deg
S-0-0053.0.0
Position feedback value 2 (external feedback)
0x76220001
deg
S-0-0060.0.0
Position switch point 1
0x6220001
deg
S-0-0061.0.0
Position switch point 2
0x6220001
deg
S-0-0062.0.0
Position switch point 3
0x6220001
deg
S-0-0063.0.0
Position switch point 4
0x6220001
deg
S-0-0064.0.0
Position switch point 5
0x6220001
deg
S-0-0065.0.0
Position switch point 6
0x6220001
deg
S-0-0066.0.0
Position switch point 7
0x6220001
deg
S-0-0067.0.0
Position switch point 8
0x6220001
deg
S-0-0068.0.0
Position switch point 9
0x6220001
deg
S-0-0069.0.0
Position switch point 10
0x6220001
deg
S-0-0070.0.0
Position switch point 11
0x6220001
deg
S-0-0071.0.0
Position switch point 12
0x6220001
deg
S-0-0072.0.0
Position switch point 13
0x6220001
deg
S-0-0073.0.0
Position switch point 14
0x6220001
deg
S-0-0074.0.0
Position switch point 15
0x6220001
deg
S-0-0075.0.0
Position switch point 16
0x6220001
deg
S-0-0076.0.0
Position data scaling type
0x40010001
S-0-0077.0.0
Linear position data scaling type
0x40110001
S-0-0078.0.0
Linear position data scaling exponent
0x40210001
S-0-0079.0.0
Rotational position resolution
0x40120001
S-0-0080.0.0
Torque command value
0x210001
1
1
--
S-0-0081.0.0
Additive torque command value
0x210001
--
S-0-0082.0.0
Positive torque limit value
0x210001
--
S-0-0083.0.0
Negative torque limit value
0x210001
--
S-0-0084.0.0
Torque feedback value
0x210001
--
S-0-0086.0.0
Torque/force data scaling type
0x40010001
8345_en_01
Minimum
PHOENIX CONTACT
25
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
S-0-0095.0.0
Diagnostic message
0x70440001
S-0-0096.0.0
Slave arrangement (SLKN)
0x70310001
S-0-0097.0.0
Mask class 2 diagnostic
S-0-0098.0.0
Minimum
Maximum
0x10001
0
65535
Mask class 3 diagnostic
0x10001
0
65535
S-0-0099.0.0
Reset class 1 diagnostic
0x90001
0
0
S-0-0100.0.0
Velocity loop proportional gain
0x120001
S-0-0101.0.0
Velocity loop integral action time
0x1110001
ms
S-0-0102.0.0
Velocity loop differential time
0x110001
ms
S-0-0103.0.0
Modulo value
0x120001
--
S-0-0104.0.0
Position loop KV-factor
0x110001
m/min
S-0-0105.0.0
Position loop integral action time
0x110001
ms
S-0-0106.0.0
Current loop proportional gain 1
0x120001
S-0-0107.0.0
Current loop integral action time 1
0x110001
µs
S-0-0108.0.0
Feedrate override
0x110001
%
S-0-0109.0.0
Motor peak current
0x3120001
A
S-0-0113.0.0
Maximum motor speed
0x4120001
1/min
S-0-0115.0.0
Position feedback 2 type
0x10001
S-0-0116.0.0
Resolution of feedback 1
0x60120001
S-0-0117.0.0
Resolution of feedback 2
0x60120001
S-0-0127.0.0
CP3 transition check
0x60090001
0
0
S-0-0128.0.0
CP4 transition check
0x50090001
0
0
S-0-0130.0.0
Probe value 1 positive edge
0x6220001
deg
S-0-0131.0.0
Probe value 1 negative edge
0x6220001
deg
S-0-0132.0.0
Probe value 2 positive edge
0x6220001
deg
S-0-0133.0.0
Probe value 2 negative edge
0x6220001
deg
S-0-0134.0.0
Drive control
0x310001
S-0-0135.0.0
Drive status
0x70310001
S-0-0146.0.0
Control unit controlled homing procedure command
0x90001
S-0-0147.0.0
Homing parameter
0x10001
S-0-0148.0.0
Drive controlled homing procedure command
0x90001
S-0-0169.0.0
Probe control
0x10001
Unit
S-0-0170.0.0
Probing cycle procedure command
0x90001
S-0-0187.0.0
IDN-list of configurable data in the AT
0x70560001
ID
S-0-0188.0.0
IDN-list of configurable data in the MDT
0x70560001
ID
S-0-0192.0.0
IDN-List of all backup operation data
0x70560001
S-0-0193.0.0
Positioning jerk
0x220001
S-0-0206.0.0
Drive on delay time
0x1110001
ms
S-0-0207.0.0
Drive off delay time
0x1110001
ms
S-0-0256.0.0
Multiplication factor 1
0x120001
S-0-0257.0.0
Multiplication factor 2
0x120001
S-0-0258.0.0
Target position
0x6220001
deg
S-0-0259.0.0
Positioning velocity
0x1220001
rpm
S-0-0260.0.0
Positioning acceleration
0x220001
--
S-0-0264.0.0
Backup working memory procedure command
0x60090001
S-0-0267.0.0
Password
0x60440001
S-0-0273.0.0
Maximum drive off delay time
0x1110001
S-0-0277.0.0
Position feedback 1 type
0x10001
S-0-0279.0.0
List of password protected data
0x60560001
S-0-0292.0.0
List of supported operation modes
0x70350001
S-0-0295.0.0
Drive enable delay time
0x1110001
S-0-0304.0.0
Real-time status bit 1
0x10001
S-0-0305.0.0
Allocation of real-time status bit 1
0x520001
S-0-0306.0.0
Real-time status bit 2
0x10001
8345_en_01
--
ms
ms
PHOENIX CONTACT
26
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
S-0-0307.0.0
Allocation of real-time status bit 2
0x520001
S-0-0359.0.0
Positioning deceleration
0x220001
S-0-0390.0.0
Diagnostic Number
0x70320001
S-0-0393.0.0
Command value mode
0x10001
S-0-0400.0.0
Home switch
0x10001
S-0-0405.0.0
Probe 1 enable
0x10001
S-0-0406.0.0
Probe 2 enable
0x10001
S-0-0409.0.0
Probe 1 positive latched
0x110001
S-0-0410.0.0
Probe 1 negative latched
0x110001
S-0-0411.0.0
Probe 2 positive latched
0x110001
Unit
Minimum
Maximum
--
S-0-0412.0.0
Probe 2 negative latched
0x110001
S-0-0415.0.0
Bit number allocation of real-time status bit 1
0x110001
0
63
S-0-0416.0.0
Bit number allocation of real-time status bit 2
0x110001
0
63
S-0-0417.0.0
Positioning velocity threshold in modulo mode
0x1120001
rpm
S-0-0418.0.0
Target position window in modulo mode
0x6120001
deg
S-0-0426.0.0
Measuring data allocation 1
0x520001
S-0-0427.0.0
Measuring data allocation 2
0x520001
S-0-0428.0.0
IDN list of configurable measuring data
0x70560001
S-0-0430.0.0
Active target position
0x6220001
S-0-0437.0.0
Positioning status
0x10001
S-0-0440.0.0
Marker position feedback 1
0x6220001
deg
S-0-0441.0.0
Marker position feedback 2
0x6220001
deg
S-0-0442.0.0
Counter marker position feedback 1
0x110001
250000
65000000
65000000
deg
S-0-0443.0.0
Counter marker position feedback 2
0x110001
S-0-1000.0.0
SCP Type & Version
0x70350001
S-0-1002.0.0
Cycle time (tScyc)
0x63120001
S-0-1003.0.0
Allowed MST losses in CP3/CP4
0x60120001
S-0-1005.0.0
Minimum feedback processing time (t5)
0x73120001
ns
S-0-1006.0.0
AT transmission starting time (t1)
0x63120001
ns
0
S-0-1007.0.0
Feedback acquisition capture point (t4)
0x63120001
ns
0
65000000
S-0-1008.0.0
Command value valid time (t3)
0x63120001
ns
0
65000000
S-0-1009.0.0
Device Control
0x60310001
S-0-1010.0.0
Lengths of MDT
0x60150001
S-0-1011.0.0
Device Status offset in AT
0x60310001
µs
S-0-1012.0.0
Lengths of ATs
0x60150001
S-0-1013.0.0
SVC offset in MDT
0x60310001
S-0-1014.0.0
SVC offset in AT
0x63310001
S-0-1015.0.0
Ring delay
0x3120001
ns
S-0-1016.0.0
Slave delay (P/S)
0x73160001
ns
S-0-1017.0.0
NRC transmission time
0x63160001
ns
S-0-1019.0.0
MAC address
0x70340001
S-0-1020.0.0
IP address
0x140001
S-0-1021.0.0
Subnet mask
0x140001
S-0-1022.0.0
Gateway address
0x140001
S-0-1023.0.0
SYNC jitter
0x63120001
S-0-1024.0.0
SYNC delay measuring procedure command
0x90001
S-0-1026.0.0
Version of communication hardware
0x70440001
S-0-1027.0.1
Maximum transmission unit sent within the NRT channel
S-0-1027.0.2
Maximum transm
S-0-1028.0.0
Error counter MST P/S
0x110001
S-0-1035.0.0
Error counter Port1 & Port2
0x320001
S-0-1040.0.0
SERCOS address
0x110001
S-0-1041.0.0
AT Command value valid time (t9)
0x63120001
8345_en_01
1048575
ns
63750
0
0
0x60110001
46
1500
0x60110001
46
1500
µs
0
511
0
65000000
PHOENIX CONTACT
27
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
S-0-1044.0.0
Device Control
0x70310001
S-0-1045.0.0
Device Status
0x70310001
S-0-1046.0.0
List of sercos addresses in device
0x70150001
S-0-1050.0.1
Configuration of the Connection
0x60310001
S-0-1050.0.2
Connection Number
0x60110001
S-0-1050.0.3
Telegram Assignment
0x60310001
S-0-1050.0.4
Max. Length Of Connection
0x70110001
S-0-1050.0.5
Actual Length of Connection
0x70110001
S-0-1050.0.6
Configuration List
0x60560001
S-0-1050.0.8
Connection Control (C-Con)
0x10001
S-0-1050.0.10
Producer Cycle Time
0x63120001
S-0-1050.0.11
Allowed Data Losses
0x60110001
S-0-1050.0.12
Error Counter Data Losses
0x70110001
S-0-1050.0.20
IDN allocation of real-time bit
0x560001
S-0-1050.0.21
Bit allocation of real-time bit
0x150001
S-0-1050.1.1
Configuration Of The Connection
0x60310001
S-0-1050.1.2
Connection Number
0x60110001
S-0-1050.1.3
Telegram Assignment
0x60310001
S-0-1050.1.4
Max. Length Of Connection
0x70110001
S-0-1050.1.5
Actual Length of Connection
0x70110001
S-0-1050.1.6
Configuration List
0x60560001
S-0-1050.1.8
Connection Control (C-Con)
0x10001
S-0-1050.1.10
Producer Cycle Time
0x63120001
S-0-1050.1.11
Allowed Data Losses
0x60110001
S-0-1050.1.12
Error Counter Data Losses
0x70110001
S-0-1050.1.20
IDN allocation of real-time bit
0x560001
S-0-1050.1.21
Bit allocation of real-time bit
0x150001
S-0-1050.2.1
Configuration Of The Connection
0x60310001
S-0-1050.2.2
Connection Number
0x60110001
S-0-1050.2.3
Telegram Assignment
0x60310001
S-0-1050.2.4
Max. Length Of Connection
0x70110001
S-0-1050.2.5
Actual Length of Connection
0x70110001
S-0-1050.2.6
Configuration List
0x60560001
S-0-1050.2.8
Connection Control (C-Con)
0x10001
S-0-1050.2.10
Producer Cycle Time
0x63120001
S-0-1050.2.11
Allowed Data Losses
0x60110001
S-0-1050.2.12
Error Counter Data Losses
0x70110001
S-0-1050.2.20
IDN allocation of real-time bit
0x560001
S-0-1050.2.21
Bit allocation of real-time bit
0x150001
S-0-1050.3.1
Configuration Of The Connection
0x60310001
S-0-1050.3.2
Connection Number
0x60110001
S-0-1050.3.3
Telegram Assignment
0x60310001
S-0-1050.3.4
Max. Length Of Connection
0x70110001
S-0-1050.3.5
Actual Length of Connection
0x70110001
S-0-1050.3.6
Configuration List
0x60560001
S-0-1050.3.8
Connection Control (C-Con)
0x10001
S-0-1050.3.10
Producer Cycle Time
0x63120001
S-0-1050.3.11
Allowed Data Losses
0x60110001
S-0-1050.3.12
Error Counter Data Losses
0x70110001
S-0-1050.3.20
IDN allocation of real-time bit
0x560001
S-0-1050.3.21
Bit allocation of real-time bit
0x150001
S-0-1051.0.0
Image of connection setups
0x70350001
S-0-1300.0.1
Component Name
0x70440001
8345_en_01
Unit
ns
ns
ns
ns
Minimum
Maximum
0
65535
2
1484
1000000
65000000
1
65535
0
65535
2
1484
1000000
65000000
1
65535
0
65535
2
1484
1000000
65000000
1
65535
0
65535
2
1484
1000000
65000000
1
65535
PHOENIX CONTACT
28
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
S-0-1300.0.2
Vendor name
0x70440001
S-0-1300.0.3
Vendor Code
0x70110001
S-0-1300.0.4
Device Name
0x70440001
S-0-1300.0.5
Device ID
0x70440001
S-0-1300.0.6
Connected to sub-device
S-0-1300.0.7
Unit
Minimum
Maximum
0x70110001
0
511
Function Revision
0x70110001
0
9999
S-0-1300.0.8
Hardware Revision
0x70440001
S-0-1300.0.9
Software Revision
0x70440001
S-0-1300.0.10
Firmware Loader Revision
0x70440001
S-0-1300.0.11
Order number
0x70440001
S-0-1300.0.12
Serial number
0x70440001
S-0-1300.0.13
Manufacturing Date
0x70440001
S-0-1300.0.20
Operational Hours
0x70120001
S-0-1301.0.0
List of GDP Classes & Version
0x70350001
S-0-1302.0.1
FSP Type & Version
0x70320001
S-0-1302.0.2
Function Groups
0x70560001
S-0-1302.0.3
Application Type
0x440001
S-0-1303.0.1
List of Diagnostic Numbers
0x360001
S-0-1303.0.3
List of faulty Function Groups
0x560001
h
S-0-1303.0.4
List of additional diag. Infos
0x50001
S-0-1500.0.1
IO Control
0x10001
S-0-1500.0.2
IO Status
0x10001
S-0-1500.0.3
Module Type Code
0x70370001
S-0-1500.0.5
Container OutputData
0x350001
S-0-1500.0.9
Container InputData
0x350001
S-0-1500.0.19
Parameter Channel Receive
0x70340001
S-0-1500.0.20
Parameter Channel Transmit
0x60340001
S-0-1500.0.32
IO Diagnosis Message
0xEC
S-0-1502.0.1
Name of IO_FG
0x440001
S-0-1502.0.2
Configuration of IO_FG
0x60010001
S-0-1502.0.3
Channel Quantity PDOUT
0x70110001
S-0-1502.0.4
Channel Size PDOUT
0x70110001
S-0-1502.0.5
PDOUT
0x10001
S-0-1502.0.19
Parameter Channel Receive
0x70340001
S-0-1502.0.20
Parameter Channel Transmit
0x70340001
S-0-1502.0.22
Fall Back Value Output
0x10001
S-0-1502.0.23
Min. Delay Time
0x70120001
ns
S-0-1502.0.24
Max. Delay Time
0x70120001
ns
S-0-1503.0.1
Name of IO_FG
0x440001
S-0-1503.0.2
Configuration of IO_FG
0x60010001
S-0-1503.0.7
Channel Quantity PDIN
0x70110001
S-0-1503.0.8
Channel Size PDIN
0x70110001
S-0-1503.0.9
PDIN
0x70010001
S-0-1503.0.19
Parameter Channel Receive
0x70340001
S-0-1503.0.20
Parameter Channel Transmit
0x70340001
S-0-1503.0.23
Min. Delay Time
0x70120001
ns
S-0-1503.0.24
Max. Delay Time
0x70120001
ns
S-0-1504.0.1
Name of IO_FG
0x440001
S-0-1504.0.2
Configuration of IO_FG
0x60010001
S-0-1504.0.3
Channel Quantity PDOUT
0x70110001
S-0-1504.0.4
Channel Size PDOUT
0x70110001
S-0-1504.0.5
PDOUT
0x110001
S-0-1504.0.19
Parameter Channel Receive
0x70340001
8345_en_01
0
PHOENIX CONTACT
29
ILB S3 24 DI8 DO4 AO2 INC-IN2
IDN
Name
Attributes
S-0-1504.0.20
Parameter Channel Transmit
0x70340001
Unit
S-0-1504.0.22
Fall Back Value Output
0x110001
S-0-1504.0.23
Min. Delay Time
0x70120001
ns
S-0-1504.0.24
Max. Delay Time
0x70120001
ns
S-0-1506.0.1
Name of IO_FG
0x440001
S-0-1506.0.2
Configuration of IO_FG
0x60010001
S-0-1506.0.7
Channel Quantity PDIN
0x70110001
S-0-1506.0.8
Channel Size PDIN
0x70110001
S-0-1506.0.9
PDIN
0x70120001
S-0-1506.0.19
Parameter Channel Receive
0x70340001
S-0-1506.0.20
Parameter Channel Transmit
0x70340001
S-0-1506.0.23
Min. Delay Time
0x70120001
ns
S-0-1506.0.24
Max. Delay Time
0x70120001
ns
P-0-1002.0.1
Reference Input Select
0x20001
P-0-1002.0.2
Overtemperature Input Select
0x20001
P-0-1002.0.3
Inverter Error Input Select
0x20001
P-0-1003.1.1
Logic Position-Switch S-0-0060 for Output 1
0x20001
P-0-1003.1.2
Logic Position-Switch S-0-0061 for Output 1
0x20001
P-0-1003.1.3
Logic Position-Switch S-0-0062 for Output 1
0x20001
P-0-1003.1.4
Logic Position-Switch S-0-0063 for Output 1
0x20001
P-0-1003.1.5
Logic Position-Switch S-0-0064 for Output 1
0x20001
P-0-1003.1.6
Logic Position-Switch S-0-0065 for Output 1
0x20001
P-0-1003.1.7
Logic Position-Switch S-0-0066 for Output 1
0x20001
P-0-1003.1.8
Logic Position-Switch S-0-0067 for Output 1
0x20001
P-0-1003.1.9
Logic Position-Switch S-0-0068 for Output 1
0x20001
P-0-1003.1.10
Logic Position-Switch S-0-0069 for Output 1
0x20001
P-0-1003.1.11
Logic Position-Switch S-0-0070 for Output 1
0x20001
P-0-1003.1.12
Logic Position-Switch S-0-0071 for Output 1
0x20001
P-0-1003.1.13
Logic Position-Switch S-0-0072 for Output 1
0x20001
P-0-1003.1.14
Logic Position-Switch S-0-0073 for Output 1
0x20001
P-0-1003.1.15
Logic Position-Switch S-0-0074 for Output 1
0x20001
P-0-1003.1.16
Logic Position-Switch S-0-0075 for Output 1
0x20001
P-0-1003.2.1
Logic Position-Switch S-0-0060 for Output 2
0x20001
P-0-1003.2.2
Logic Position-Switch S-0-0061 for Output 2
0x20001
P-0-1003.2.3
Logic Position-Switch S-0-0062 for Output 2
0x20001
P-0-1003.2.4
Logic Position-Switch S-0-0063 for Output 2
0x20001
P-0-1003.2.5
Logic Position-Switch S-0-0064 for Output 2
0x20001
P-0-1003.2.6
Logic Position-Switch S-0-0065 for Output 2
0x20001
P-0-1003.2.7
Logic Position-Switch S-0-0066 for Output 2
0x20001
P-0-1003.2.8
Logic Position-Switch S-0-0067 for Output 2
0x20001
P-0-1003.2.9
Logic Position-Switch S-0-0068 for Output 2
0x20001
P-0-1003.2.10
Logic Position-Switch S-0-0069 for Output 2
0x20001
P-0-1003.2.11
Logic Position-Switch S-0-0070 for Output 2
0x20001
P-0-1003.2.12
Logic Position-Switch S-0-0071 for Output 2
0x20001
P-0-1003.2.13
Logic Position-Switch S-0-0072 for Output 2
0x20001
P-0-1003.2.14
Logic Position-Switch S-0-0073 for Output 2
0x20001
P-0-1003.2.15
Logic Position-Switch S-0-0074 for Output 2
0x20001
P-0-1003.2.16
Logic Position-Switch S-0-0075 for Output 2
0x20001
P-0-1004.0.1
Select Analogue Output Signal
0x20001
P-0-1004.0.4
Analogue Output Value
0x72220001
P-0-1005.1.1
Select Digital Output Signal 1
0x20001
P-0-1005.2.1
Select Digital Output Signal 2
0x20001
8345_en_01
Minimum
Maximum
Volt
PHOENIX CONTACT
30
ILB S3 24 DI8 DO4 AO2 INC-IN2
15
Parameter descriptions
P-0-1002.0.1: Reference Input Select
Name
Attributes
Reference Input Select
Length (Octet)
Data Type and Display Format
Function
Decimal Point
Write Protection
Conversion Factor
Unit
Minimum Value
Maximum Value
Scaling / Resolution
Structure of reference input select
Bit 0 to bit 3 0000 No input
0001 - Digital input 1
0010 - Digital input 2
0011 - Digital input 3
0100 - Digital input 4
P-0-1002.0.3: Generic Driver Error Input Select
4
Binary
Parameters
n/a
n/a
1
n/a
n/a
n/a
No
Name
Attributes
Generic Driver Error Input Select
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Generic Driver Error Input Select
(Input is LOW active!)
Bit 0 to bit 3 0000 No input
0001 - Digital input 1
0010 - Digital input 2
0011 - Digital input 3
0100 - Digital input 4
P-0-1002.0.2: Over-Temperature Input Select
Name
Attributes
Over-Temperature Input Select
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of overtemperature input select
(The input is LOW active!)
Bit 0 to bit 3 0000 No input
0001 - Digital input 1
0010 - Digital input 2
0011 - Digital input 3
0100 - Digital input 4
8345_en_01
P-0-1003.0.1: Logic Position-Switch S-0-0060 for Output x
Name
Logic Position-Switch S-0-0060
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0060 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
PHOENIX CONTACT
31
ILB S3 24 DI8 DO4 AO2 INC-IN2
P-0-1003.0.2: Logic Position-Switch S-0-0061 for Output x
Name
Logic Position-Switch S-0-0061 for
Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0061 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
P-0-1003.0.3: Logic Position-Switch S-0-0062 for Output x
Name
Logic Position-SwitchS-0-0062
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0062 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
8345_en_01
P-0-1003.0.4: Logic Position-Switch S-0-0063 for Output x
Name
Logic Position-Switch S-0-0063
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0063 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
P-0-1003.0.5: Logic Position-Switch S-0-0064 for Output x
Name
Logic Position -Switch S-0-0064
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0064 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
PHOENIX CONTACT
32
ILB S3 24 DI8 DO4 AO2 INC-IN2
P-0-1003.0.6: Logic Position-Switch S-0-0065 for Output x
Name
Logic Position-Switch S-0-0065
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0065 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
P-0-1003.0.7: Logic Position-Switch S-0-0066 for Output x
Name
Logic Position -SwitchS-0-0066
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0066 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
8345_en_01
P-0-1003.0.8: Logic Position-Switch S-0-0067 for Output x
Name
Logic Position-Switch S-0-0067
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0067 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
P-0-1003.0.9: Logic Position-Switch S-0-0068 for Output x
Name
Logic Position-Switch S-0-0068
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0068 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
PHOENIX CONTACT
33
ILB S3 24 DI8 DO4 AO2 INC-IN2
P-0-1003.0.10: Logic Position-Switch S-0-0069 for Output x
Name
Logic Position-Switch S-0-0069
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0069 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
P-0-1003.0.11: Logic Position-Switch S-0-0070 for Output x
Name
Logic Position-Switch S-0-0070 for
Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0070 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
8345_en_01
P-0-1003.0.12: Logic Position-Switch S-0-0071 for Output x
Name
Logic Position -Switch S-0-0071
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0071 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
P-0-1003.0.13: Logic Position-Switch S-0-0072 for Output x
Name
Logic Position-Switch S-0-0072
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0072 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
PHOENIX CONTACT
34
ILB S3 24 DI8 DO4 AO2 INC-IN2
P-0-1003.0.14: Logic Position-Switch S-0-0073 for Output x
Name
Logic Position-Switch S-0-0073
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0073 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
P-0-1003.0.16: Logic Position-Switch S-0-0075 for Output x
Name
Logic Position-Switch S-0-0075
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0075 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
P-0-1003.0.15: Logic Position-Switch S-0-0073 for Output x
Name
Logic Position-SwitchS-0-0074
for Output x
Attributes
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Logic Position-Switch S-0-0074 for Output x
Bit 0 to bit 1 00 - No response
01 - Reset output
10 - Set output
11 - Invert output
8345_en_01
PHOENIX CONTACT
35
ILB S3 24 DI8 DO4 AO2 INC-IN2
P-0-1004.0.1: Select Analog Output Signal
Name
Attributes
Select Analog Output Signal
Length (Octet)
Data Type and Display Format
Function
Decimal Point
Write Protection
Conversion Factor
Unit
Minimum Value
Maximum Value
Scaling / Resolution
Structure of Select Analog Output Signal
Bit 0 to bit 3 0000 - Output 0 V
0001 - Speed setpoint output
(after homing)
0010 - Output S-0-0036.0.0
0011 - Output S-0-0037.0.0
0100 - Output S-0-0036.0.0 +
S-0-0037.0.0
0101 - Output S-0-0080.0.0
0110 - Output S-0-0081.0.0
0111 - Output S-0-0080.0.0 +
S-0-0081.0.0
1000 - Output S-0-0040.0.0
1001 - Output S-0-1504.0.5
P-0-1005.1.1: Select Digital Output Signal 1
4
Binary
Parameters
n/a
n/a
1
n/a
n/a
n/a
No
Name
Attributes
Select Digital Output Signal 1
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Select Digital Output Signal 1
Bit 0 to bit 3 0000 - Output FALSE
0001 - Output TRUE
0010 - Output logic position switch 1
0011 - Output S-0-0304.0.0
0100 - Output S-0-0306.0.0
0100 - Output S-0-0306.0.0
0101 - Output S-0-1502.0.5
0110 - Bit 14/15 from IDN/S-0-0134
(Bit14 and Bit15 = OUT1)
P-0-1004.0.2: Analog Output Value
To read the controller outputs (if switched as such)
Name
Attributes
Analog Output Value
Length (Octet)
Data Type and Display Format
Function
Decimal Point
Write Protection
Conversion Factor
Unit
Minimum Value
Maximum Value
Scaling / Resolution
8345_en_01
4
Signed32
Parameters
2
Yes
0.01
n/a
-10.00
10.00
0.01
PHOENIX CONTACT
36
ILB S3 24 DI8 DO4 AO2 INC-IN2
P-0-1005.2.1: Select Digital Output Signal 2
Name
Attributes
Select Digital Output Signal 2
Length (Octet)
4
Data Type and Display Format Binary
Function
Parameters
Decimal Point
n/a
Write Protection
n/a
Conversion Factor
1
Unit
n/a
Minimum Value
n/a
Maximum Value
n/a
Scaling / Resolution
No
Structure of Select Digital Output Signal 2
Bit 0 to bit 3 0000 - Output FALSE
0001 - Output TRUE
0010 - Output logic position switch 2
0011 - Output S-0-0304.0.0
0100 - Output S-0-0306.0.0
0100 - Output S-0-0306.0.0
0101 - Output S-0-1502.0.5
0110 - Bit 14/15 from IDN/S-0-0134
(Bit14 and Bit15 = OUT2)
8345_en_01
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
www.phoenixcontact.com