0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2700273

2700273

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    信号转换器 Axioline 系列

  • 数据手册
  • 价格&库存
2700273 数据手册
AXL E IOL AI1 U M12 R Axioline E IO-Link/analog converter for connecting an analog sensor, 0 V ... 10 V, rectangular version Data sheet 8586_en_03 1 © PHOENIX CONTACT 2014-09-22 Description The IO-Link/analog converter is an IO-Link slave that converts analog signals into the IO-Link protocol. It therefore offers the option of acquiring the signals of analog sensors via an IO-Link master. Features – – – – – – – – – Rectangular version 1 IO-Link interface 1 analog input Connection of the sensor in 3-wire technology Voltage range: 0 V ... 10 V IO-Link and sensor connections via M12 connectors FE connection for local connection to functional earth ground Supply of the module electronics and the sensor via the IO-Link interface of the IO-Link master Diagnostic indicator Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. AXL E IOL AI1 U M12 R 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 3 5 Additional tables ...................................................................................................................... 5 6 Internal circuit diagram ............................................................................................................ 5 7 Pin assignment ........................................................................................................................ 6 7.1 Connections on the device ..................................................................................................... 6 7.2 Pin assignment of the IO-Link interface ..................................................................................... 6 7.3 Pin assignment of the analog input ........................................................................................... 6 8 Connection notes .................................................................................................................... 6 9 Connection example................................................................................................................ 6 10 Assembly................................................................................................................................. 7 11 Local status indicator............................................................................................................... 7 12 Process data............................................................................................................................ 8 12.1 IN process data ................................................................................................................... 8 12.2 OUT process data................................................................................................................ 8 12.3 Parameterization via OUT process data .................................................................................... 9 12.4 Example for changing from S7-compatible (default) to IB IL and for forming 16-sample mean value ......... 9 13 Significant values in various formats...................................................................................... 10 13.1 IB IL format ...................................................................................................................... 10 13.2 S7-compatible format ......................................................................................................... 10 14 IO-Link objects ...................................................................................................................... 11 14.1 Overview of the objects ....................................................................................................... 11 14.2 Parameterization (80hex: ParaWord) ....................................................................................... 12 8586_en_03 PHOENIX CONTACT 2 AXL E IOL AI1 U M12 R 3 Ordering data Description Type Order No. Pcs. / Pkt. Axioline E-IO-Link/analog converter for connecting an analog sensor, 0 V ... 10 V, M12 fast connection technology, rectangular version AXL E IOL AI1 U M12 R 2700273 1 4 Technical data Dimensions (nominal sizes in mm) 66,5 41 29 16,6 28 50 Width 16.6 mm Height 42 mm Depth 66.5 mm General data Weight 34 g Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -25 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % Permissible humidity (storage/transport) 5 % ... 95 % Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP65/67 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Pollution degree 2 IO-Link Specification V1.1.1 Protection against polarity reversal Yes Transmission speed 230,4 kBit/s (COM3) Frame type 1 Cycle Time min. 2 ms Process data update 2 ms Amount of process data 16 Bit (Input data), 16 Bit (Output data) IO-Link ports Number of ports 1 Connection method M12 connector, A-coded 8586_en_03 PHOENIX CONTACT 3 AXL E IOL AI1 U M12 R IO-Link port supply Typical current consumption 16.5 mA ±15% (at 24 V DC) Current consumption max. 120 mA Protection against polarity reversal Yes Short-circuit protection Yes Overload protection Yes I/O supply voltage 24 V DC This supply voltage is provided via the IO-Link interface of the IO-Link Sensor supply voltage 24 V DC (max. 100 mA) This supply voltage is provided via the I/O supply voltage. master. Analog input Number of inputs 1 (voltage) Connection method M12 connector, A-coded Connection method 3-wire (optionally 4-wire) Voltage input signal 0 V ... 10 V Input resistance of voltage input min. 100 kΩ Resolution A/D 12 bit Data formats IB IL, S7-compatible Filtering None or mean-value generation over 4, 16, or 32 measured values Precision < 0.25 % (From the measuring range final value in the nominal range) Permissible cable length max. 30 m (shielded cable) Error messages to the higher level control or computer system Overrange or underrange Message in the diagnostic code (in the IB IL format) Measured value invalid/no valid measured value present Message in the diagnostic code (in the IB IL format) Module faulty Message in the diagnostic code (in the IB IL format) Mechanical tests Vibration resistance in acc. with EN  60068-2-6/IEC  60068-2-6 Operation: 2g Vibration resistance in acc. with EN  60068-2-6/IEC  60068-2-6 Storage/transport: 5g Shock in acc. with EN  60068-2-27/IEC  60068-2-27 Operation: 30g, 11 ms, three shocks in each space direction Shock in acc. with EN  60068-2-27/IEC  60068-2-27 Storage/transport: 50g, 11 ms, three shocks in each space direction Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g, 16 ms, 1000 shocks, in all space directions Approvals For the latest approvals, please visit phoenixcontact.net/products. 8586_en_03 PHOENIX CONTACT 4 AXL E IOL AI1 U M12 R Internal circuit diagram The data is valid for nominal operation (supply voltage = 24 V) in the default configuration (measurement range 0 V ... 10 V). IO-Link Tolerance and temperature response at TA = -25°C to +60°C L+ C/Q IO-Link IC µC 1 4 3 FE L- Drift Typical Maximum ±45 ppm/K ±75 ppm/K Analog 6 Protection Additional tables Protection 5 FE The tolerance values refer to the measuring range final value. Figure 1 Internal wiring of connections Key: Tolerances influenced by electromagnetic interference Type of electromagnetic interference Standard Tolerance Criterion Electromagnetic fields EN 61000-4-3/ IEC 61000-4-3 < ±2.0% A Fast transients (burst) EN 61000-4-4/ IEC 61000-4-4 < ±1.0% A Conducted interference EN 61000-4-6/ IEC 61000-4-6 < ±0.5% A 8586_en_03 Protective circuit Protection IO-Link IC µC IO-Link circuit Microprocessor Analog/digital converter PHOENIX CONTACT 5 AXL E IOL AI1 U M12 R 7 Pin assignment 7.1 Connections on the device 7.3 Pin assignment of the analog input 2 1 5 1 2 3 4 Figure 4 Pin assignment of the analog input (M12 A-coded, socket) 3 Figure 2 Connections on the converter No. Connection 1 IO-Link interface (indicated by IO-Link symbol) 2 Fixing options; options for connection to functional earth ground 3 Analog input Pin 1 2 3 4 5 8 Connection notes Pin assignment of the IO-Link interface 2 1 Always connect the analog sensors using shielded, twisted pair cables. 9 4 3 1 4 Signal L+ 2 3 4 LC/Q Meaning +24 V supply voltage; from IO-Link master Not used GND, reference potential for L+ IO-Link data transmission channel 1 5 4 L+ 2 3 +24 V 0...10 V Pin 1 8586_en_03 2 3 Pin assignment of the I/O link interface (M12 A-coded, pin) L- Figure 3 Connection example C/Q 7.2 Assignment +24 V, 100 mA sensor supply Not used GND Voltage input 0 V ... 10 V Not used Figure 5 Connection example PHOENIX CONTACT 6 AXL E IOL AI1 U M12 R 10 Assembly 11 Local status indicator COM Figure 6 • • • Connection of a sensor to an IO-Link master via the converter Connect the IO-Link interface of the converter to an IOLink port of the higher-level IO-Link master using a standardized 3-pos. cable. Connect the analog sensor directly to the analog converter input or using a shielded 4-pos. cable. Fasten each connection using the M12 connectors. Figure 7 Local status indicator Designation COM Color Mean- State ing Green Status of ON IO-Link Flashing device OFF In environments with high levels of interference, in particular, Phoenix Contact recommends connecting the converter to an appropriate functional earth ground point using an M4 screw. 8586_en_03 Description Supply voltage OK Supply voltage OK, SDCI communication active No supply voltage, no communication PHOENIX CONTACT 7 AXL E IOL AI1 U M12 R 12 Process data The device occupies one word of IN process data and one word of OUT process data. 12.1 IN process data The measured values are depicted in IB IL or S7-compatible format. For both formats the measured value is represented in bits 14 to 3. Bit 15 is available as a sign bit. Bits 2 to 0 are not relevant for the measured value. 15 V V x 14 13 12 11 10 9 Analog value 8 7 6 5 4 3 2 x 1 x 0 x Sign bit (= 0, not relevant) Not relevant for the measured value (are set to 0) A diagnostic code is mapped to the input data in the event of an error. IB IL format The values > 8000hex and 0008) accords 2.67 V Input data hex 8001 7EF8 7538 7530 3A98 0008 0000 8002 13.2 Range dec 32769 32511 30008 30000 15000 8 0 32770 Overrange Overdrive range (End) Overrange (Start) Nominal range (End) Nominal range Nominal range Nominal range (Start) Wire break 0 V ... 10 V V > 10.837 10.837 10.000267 10.0 5.0 0.00267 0 S7-compatible format Resolution: 1 bit (0000 -> 0008) accords 2.89 V Input data hex 7FFF 7EF0 6C08 6C00 3600 0008 0000 8000 Range dec 32767 32503 27656 27648 13824 8 0 32768 Overrange Overdrive range (End) Overrange (Start) Nominal range (End) Nominal range Nominal range Nominal range (Start) Wire break/short circuit 0 V ... 10 V V > 11.756 11.756 10.00289 10.0 5.0 0.00289 0 The value 8000hex is specified in S7-compatible format for all errors for which diagnostic codes 8001hex to 8040hex are output in IB IL format. 8586_en_03 PHOENIX CONTACT 10 AXL E IOL AI1 U M12 R 14 IO-Link objects 14.1 Overview of the objects Index (hex) DPP ISDU Identification 07   08 09   0A 0B   10 11 12 13 14 15 16 17 Diagnostics   20 28 Parameter   80 Abbreviation R W 8586_en_03 Object name Length in Access Meaning bytes Contents Vendor ID 2 R Manufacturer identification Device ID 3 R Device ID VendorName VendorText ProductName Product ID ProductText Max. 64 Max. 64 Max. 64 Max. 64 Max. 64 R R R R R Manufacturer name Notes Product designation Order No. Product text Serial number HardwareVersion FirmwareVersion Max. 16 Max. 64 Max. 64 R R R Serial number Hardware version Firmware version 00hex B0hex 01hex 00hex 00hex Phoenix Contact www.phoenixcontact.com AXL E IOL AI1 U M12 R 2700273 IO-Link/analog converter voltage input rectangular Stored in the production process. E.g., 01 E.g., 001 Error count 2 InputProcessData 2 R R Errors since power up Input process data Number of errors Last current data ParaWord R/W Parameterization 0000hex 2 Meaning Read Write PHOENIX CONTACT 11 AXL E IOL AI1 U M12 R 14.2 Parameterization (80hex: ParaWord) Parameterize the device using this object. In the case of valid parameters, the parameterization is permanently stored on the device. After a reset, the device operates with the last permanently stored data. Upon delivery, the device operates with the default data (default settings). Saving data to the device leads to a communication failure of around 30 ms. 15 14 13 12 Reserved 11 10 9 8 Filter 7 6 Reserved 5 4 Format 3 2 1 Reserved 0 In the following tables the values in bold are default settings. Format Code (bin) 00 10 Other Meaning S7-compatible IB IL Reserved Filter Code (bin) 00 01 10 11 Meaning No filter 4-sample mean-value 16-sample mean-value 32-sample mean-value 8586_en_03 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com 12
2700273 价格&库存

很抱歉,暂时无法提供与“2700273”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2700273
    •  国内价格 香港价格
    • 1+1195.445601+143.54300

    库存:14