    AXL E IOL RTD1 M12 R

  • 数据手册
  • 价格&库存
2700305 数据手册
AXL E IOL RTD1 M12 R Axioline E IO-Link/analog converter for connecting an RTD, rectangular version Data sheet 8590_en_06 1 © PHOENIX CONTACT 2014-09-22 Description The IO-Link/analog converter is an IO-Link slave that converts analog signals into the IO-Link protocol. It therefore offers the option of acquiring the signals of analog sensors via an IO-Link master. Features – – – – – – – – Rectangular version 1 IO-Link interface 1 analog input for connecting resistance temperature detectors (RTDs) Connection of the sensor in 3-wire technology IO-Link and sensor connections via M12 connectors FE connection for local connection to functional earth ground Supply of the module electronics and the sensor via the IO-Link interface of the IO-Link master Diagnostic indicator Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. AXL E IOL RTD1 M12 R 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 3 5 Additional tables ...................................................................................................................... 5 6 Internal circuit diagram ............................................................................................................ 5 7 Pin assignment ........................................................................................................................ 6 7.1 Connections on the device ..................................................................................................... 6 7.2 Pin assignment of the IO-Link interface ..................................................................................... 6 7.3 Pin assignment of the analog input ........................................................................................... 6 8 Connection notes .................................................................................................................... 6 9 Connection example................................................................................................................ 6 10 Assembly................................................................................................................................. 7 11 Local status indicator............................................................................................................... 7 12 Process data............................................................................................................................ 8 12.1 IN process data ................................................................................................................... 8 12.2 OUT process data................................................................................................................ 8 12.3 Parameterization via OUT process data .................................................................................... 9 12.4 Example ............................................................................................................................ 9 13 Significant values in various formats...................................................................................... 10 13.1 IB IL format ...................................................................................................................... 10 13.2 S7-compatible format ......................................................................................................... 10 14 IO-Link objects ...................................................................................................................... 11 14.1 Overview of the objects ....................................................................................................... 11 14.2 Parameterization (80hex: ParaWord) ....................................................................................... 12 8590_en_06 PHOENIX CONTACT 2 AXL E IOL RTD1 M12 R 3 Ordering data Description Type Order No. Pcs. / Pkt. Axioline E-IO-Link/analog converter for connecting a temperature measurement resistor, M12 fast connection technology, rectangular version AXL E IOL RTD1 M12 R 2700305 1 4 Technical data Dimensions (nominal sizes in mm) 66,5 41 29 16,6 28 50 Width 16.6 mm Height 42 mm Depth 66.5 mm General data Weight 34 g Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -25 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % Permissible humidity (storage/transport) 5 % ... 95 % Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP65/67 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Pollution degree 2 IO-Link Specification V1.1.1 Protection against polarity reversal Yes Transmission speed 230,4 kBit/s (COM3) Frame type 1 Cycle Time min. 2 ms Process data update 2 ms Amount of process data 16 Bit (Input data), 16 Bit (Output data) IO-Link ports Number of ports 1 Connection method M12 connector, A-coded 8590_en_06 PHOENIX CONTACT 3 AXL E IOL RTD1 M12 R IO-Link port supply Typical current consumption 16.5 mA ±15% (at 24 V DC) Current consumption max. 135 mA Protection against polarity reversal Yes Short-circuit protection Yes Overload protection Yes I/O supply voltage 24 V DC This supply voltage is provided via the IO-Link interface of the IO-Link master. Analog RTD input Number of inputs 1 (for resistance temperature detectors) Connection method M12 connector, A-coded Connection method 3-wire (optionally 4-wire) Sensor types (RTD) that can be used Pt 100, Pt 1000 Linear resistance measuring range IB IL format: 0 Ω ... 500 Ω, 0 Ω ... 5 kΩ S7-compatible format: 0 Ω ... 600 Ω, 0 Ω ... 6 kΩ Resolution A/D 12 bit Data formats IB IL, S7-compatible Relative accuracy < 0.3 % (from the measuring range final value in the nominal range) Permissible cable length max. 30 m (shielded cable) Protection against polarity reversal yes Short-circuit protection yes Overload protection yes Error messages to the higher level control or computer system Overrange or underrange Message in the diagnostic code (in the IB IL format) Measured value invalid/no valid measured value present Message in the diagnostic code (in the IB IL format) Configuration invalid Message in the diagnostic code (in the IB IL format) Module faulty Message in the diagnostic code (in the IB IL format) Mechanical tests Vibration resistance in acc. with EN  60068-2-6/IEC  60068-2-6 Operation: 2g Vibration resistance in acc. with EN  60068-2-6/IEC  60068-2-6 Storage/transport: 5g Shock in acc. with EN  60068-2-27/IEC  60068-2-27 Operation: 30g, 11 ms, three shocks in each space direction Shock in acc. with EN  60068-2-27/IEC  60068-2-27 Storage/transport: 50g, 11 ms, three shocks in each space direction Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g, 16 ms, 1000 shocks, in all space directions Approvals For the latest approvals, please visit phoenixcontact.net/products. 8590_en_06 PHOENIX CONTACT 4 AXL E IOL RTD1 M12 R Internal circuit diagram The data is valid for nominal operation (supply voltage = 24 V) in the default configuration. Sensor type Measuring range Drift Lower limit Upper limit Typical IO-Link Tolerance and temperature response at TA = -25°C to +60°C L+ C/Q IO-Link IC µC 1 4 3 FE L- Analog 6 Protection Additional tables Protection 5 Maximum Pt 100 DIN -200 °C +850 °C ±5 ppm/K ±95 ppm/K Pt 1000 SAMA -200 °C +850 °C ±20 ppm/K ±95 ppm/K Linear resistor RLin 600 Ω (linear range 1) 0Ω 500 Ω ±5 ppm/K ±95 ppm/K Linear resistor RLin 6000 Ω (linear range 2) 0Ω FE Figure 1 Internal wiring of connections Key: Protective circuit Protection 5000 Ω ±34 ppm/K ±95 ppm/K IO-Link IC The tolerance values refer to the measuring range final value. µC IO-Link circuit Microprocessor Analog/digital converter Tolerances influenced by electromagnetic interference Type of electromagnetic interference Standard Tolerance Criterion Electromagnetic fields EN 61000-4-3/ IEC 61000-4-3 < ±1.5% A Fast transients (burst) EN 61000-4-4/ IEC 61000-4-4 < ±0.5% A Conducted interference EN 61000-4-6/ IEC 61000-4-6 < ±1.0% A 8590_en_06 PHOENIX CONTACT 5 AXL E IOL RTD1 M12 R 7 Pin assignment 7.1 Connections on the device 7.3 Pin assignment of the analog input 2 1 5 1 2 3 4 Figure 4 Pin assignment of the analog input (M12 A-coded, socket) 3 Figure 2 Connections on the converter No. Connection 1 IO-Link interface (indicated by IO-Link symbol) 2 Fixing options; options for connection to functional earth ground 3 Analog input Pin 1 2 3 4 5 8 Connection notes Pin assignment of the IO-Link interface 1 9 4 3 Pin assignment of the I/O link interface (M12 A-coded, pin) 2 1 3 4 L- Figure 3 Connection example LC/Q 8590_en_06 1 5 3 4 Figure 5 2 I+ 2 3 4 Meaning +24 V supply voltage; from IO-Link master Not used GND, reference potential for L+ IO-Link data transmission channel IU- Signal L+ U+ Pin 1 L+ 2 Always connect the analog sensors using shielded, twisted pair cables. C/Q 7.2 Assignment U+ RTD sensor + I+ Constant current supply + URTD sensor IConstant current supply Not used   Connection example PHOENIX CONTACT 6 AXL E IOL RTD1 M12 R 10 Assembly 11 Local status indicator COM Figure 6 • • • Connection of a sensor to an IO-Link master via the converter Connect the IO-Link interface of the converter to an IOLink port of the higher-level IO-Link master using a standardized 3-pos. cable. Connect the analog sensor directly to the analog converter input or using a shielded 4-pos. cable. Fasten each connection using the M12 connectors. Figure 7 Local status indicator Designation COM Color Mean- State ing Green Status ON of IOFlashing Link device OFF In environments with high levels of interference, in particular, Phoenix Contact recommends connecting the converter to an appropriate functional earth ground point using an M4 screw. 8590_en_06 Description Supply voltage OK Supply voltage OK, SDCI communication active No supply voltage, no communication PHOENIX CONTACT 7 AXL E IOL RTD1 M12 R 12 Process data The device occupies one word of IN process data and one word of OUT process data. 12.1 IN process data The measured values are depicted in IB IL or S7-compatible format. 15 V V 14 13 12 11 10 9 8 Analog value 7 6 5 4 3 2 1 0 Sign bit (= 0, not relevant) By some formats bit 2 ... bit 0 are not relevant for the measured value. They are set to 0. A diagnostic code is mapped to the input data in the event of an error. IB IL format Values > 8000hex and 525 525 100 5 0.5 0.1 0 - R 0 Ω ... 5 kΩ 1Ω Ω no (0 Ω) yes > 5250 5250 1000 50 5 1 0 - R 0 Ω ... 600 Ω 0.17 Ω Ω no (0 Ω) yes > 705.4 705.4 339 184.5 21.7 1.1 0.17 0 - R 0 Ω ... 6 kΩ 1.7 Ω Ω no (0 Ω) yes > 7054 7054 3390 1845 217 11 1.7 0 - 0.1 °C * °C yes yes > 850 850 525 100 5 0.5 0 -100 -200 < -200 Temperature sensors 0.1 °F * °F yes yes >1562 1562 850 525 100 5 0.5 0 -100 -200 -328 < -328 0.1 °C * °C yes yes > 850 850 100 50 0.5 0 -100 -200 < -200 Temperature sensors 0.1 °F * °F yes yes > 1562 1562 850 100 50 0.5 0 -100 -200 < -328 < -328 S7-compatible format Input data Resolution hex dec 8000 Short-circuit 8000 Wire break 7FFF Overrange 7EF8 32504 3D04 15620 2134 8500 03E8 1000 0032 50 0008 8 0005 5 0000 0 FC18 -1000 F830 -2000 F330 -3280 8000 Underrange * The format representation is based on 0.1 °C/F. The actual resolution is 0.5 °C/F. The measurement is thus always in 0.5 °C/F increments (steps). 8590_en_06 PHOENIX CONTACT 10 AXL E IOL RTD1 M12 R 14 IO-Link objects 14.1 Overview of the objects Index (hex) DPP ISDU Identification 07   08 09   0A 0B   10 11 12 13 14 15 Object name Length in Access bytes Meaning Contents Vendor ID 2 R Manufacturer identification Device ID 3 R Device ID VendorName VendorText ProductName Product ID ProductText Max. 64 Max. 64 Max. 64 Max. 64 Max. 64 R R R R R Manufacturer name Notes Product designation Order No. Product text Serial number Max. 16 R Serial number HardwareVersion FirmwareVersion Max. 64 Max. 64 R R Hardware version Firmware version 00hex B0hex 01hex 00hex 50hex Phoenix Contact www.phoenixcontact.com AXL E IOL RTD1 M12 R 2700305 IO-Link/analog converter temperature RTD input rectangular Stored in the production process. E.g., 01 E.g., 001 16 17 Diagnostics   20 28 Parameter   80 Error count InputProcessData 2 2 R R Errors since power up Input process data Number of errors Last current data ParaWord 2 R/W Parameterization 0000hex Abbreviation R W Meaning Read Write 8590_en_06 PHOENIX CONTACT 11 AXL E IOL RTD1 M12 R 14.2 Parameterization (80hex: ParaWord) Parameterize the device using this object. In the case of valid parameters, the parameterization is permanently stored on the device. After a reset, the device operates with the last permanently stored data. Upon delivery, the device operates with the default data (default settings). Saving data to the device leads to a communication failure of around 30 ms. 15 14 13 12 Reserved 11 10 9 8 7 6 Resolution for sensor type 5 4 Format 3 2 1 Sensor type 0 In the following tables the values in bold are default settings. Sensor type Code (bin) 0000 0001 1110 1111 Meaning Pt 100 DIN Pt 1000 SAMA IB IL format: Linear R 0 Ω ... 500 Ω S7-compatible format: Linear R 0 Ω ... 600 Ω IB IL format: Linear R 0 Ω ... 5 kΩ Other S7-compatible format Linear R 0 Ω ... 6 kΩ Reserved Format Code (bin) 00 10 Other Meaning S7-compatible IB IL Reserved Resolution for sensor type Code (bin) Temperature sensors 00 0.1 °C 10 (0.5 °C increments) 0.1 °F Other (0.5 °F increments) Reserved 8590_en_06 Linear R 0 Ω ... 500 Ω / 600 Ω IB IL format: 0,1 Ω Linear R 0 Ω ... 5 kΩ / 6 kΩ Format IB IL: 1,0 Ω S7-compatible format: 0,17 Ω Reserved Format S7-kompatibel: 1,7 Ω Reserved PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com 12
2700305 价格&库存

很抱歉,暂时无法提供与“2700305”相匹配的价格&库存,您可以联系我们找货

免费人工找货