Safety relay for emergency stop, safety doors, and light grids up to SILCL 3, Cat. 4, PL e, 1 or 2-channel
operation, automatic or manual, monitored start, 3 enabling current paths, 1 signaling current path,
US = 24 ... 230 V AC/DC, plug-in spring-cage terminal block
The figure shows a version with a
screw connection
Why buy this product
Up to Cat.4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061
One or two-channel activation
3 enabling current paths, 1 signaling current path
Manually monitored and automatic activation in a single device
Cross-circuit detection
Key Commercial Data
Packing unit
1
GTIN
GTIN
4046356912709
Custom tariff number
85371098
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
22.5 mm
04/14/2017 Page 1 / 6
https://www.phoenixcontact.com/us/products/2700525
Safety relays - PSR-MC32-3NO-1NC-24-230UC-SP - 2700525
Technical data
Dimensions
Height
117.4 mm
Depth
114.5 mm
Ambient conditions
Ambient temperature (operation)
-40 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Max. permissible relative humidity (operation)
75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)
75 % (on average, 85% infrequently, non-condensing)
Shock
15g
Vibration (operation)
10 Hz ...150 Hz, 2g
Maximum altitude
≤ 2000 m (Above sea level)
Input data
Rated control circuit supply voltage US
24 V AC/DC ... 230 V AC/DC -15 % / +10 %
Rated control supply current IS
typ. 103 mA (24 V DC)
typ. 47 mA (48 V DC)
typ. 38 mA (110 V AC)
typ. 21 mA (230 V AC)
Power consumption at US
2.7 W (with DC)
2.9 W (with AC)
Inrush current
< 80 A (Δt = 50 µs at Us)
Current consumption
< 5 mA (at Us/Ix to S10/S12/S13/S34/S35)
> -5 mA (with Us/Ix to S22)
Voltage at input/start and feedback circuit
24 V DC -20 % / +25 %
Typical response time
< 150 ms (automatic start)
< 100 ms (manual, monitored start)
Typ. starting time with Us
< 200 ms (when controlled via A1)
Typical release time
< 20 ms (when actuation is via the sensor circuit)
Concurrence input 1/2
∞
Recovery time
< 500 ms
Status display
3 x green LED
Maximum switching frequency
1 Hz
Max. permissible overall conductor resistance
150 Ω
Filter time
2 ms (at A1 in the event of voltage dips at Us)
max. 1.5 ms (to S10-S12; test pulse width; at 24 V DC)
7.5 ms (to S10-S12; test pulse rate; at 24 V DC)
Test pulse rate = 5 x Test pulse width
Output data
04/14/2017 Page 2 / 6
https://www.phoenixcontact.com/us/products/2700525
Safety relays - PSR-MC32-3NO-1NC-24-230UC-SP - 2700525
Technical data
Output data
Contact type
3 enabling current paths
1 signaling current path
Contact material
AgSnO2
Minimum switching voltage
5 V AC/DC
Maximum switching voltage
250 V AC/DC (Observe the load curve)
Limiting continuous current
6 A (N/O contact)
6 A (N/C contact)
Inrush current, minimum
10 mA
Maximum inrush current
6A
Sq. Total current
72 A (observe derating)
Interrupting rating (ohmic load) max.
1500 VA (N/O contact, 250 V AC, τ = 0 ms)
2
For additional values, see load curve
Maximum interrupting rating (inductive load)
48 W (N/O contact, 24 V DC, τ = 40 ms)
40 W (N/O contact, 48 V DC, τ = 40 ms)
36 W (N/O contact, 60 V DC, τ = 40 ms)
35 W (N/O contact, 110 V DC, τ = 40 ms)
33 W (N/O contact, 220 V DC, τ = 40 ms)
1500 VA (N/O contact, 250 V AC, τ = 40 ms)
Switching capacity
min. 50 mW
Switching capacity according to IEC 60947-5-1
5 A (24 V (DC13))
5 A (250 V (AC15))
Output fuse
6 A gL/gG
4 A gL/gG (for low-demand applications)
General
Relay type
Electromechanical relay with forcibly guided contacts in accordance with
EN 50205
Mechanical service life
10 x 10 cycles
Nominal operating mode
100% operating factor
Net weight
235.4 g
Mounting type
DIN rail mounting
Assembly instructions
See derating curve
Mounting position
vertical or horizontal
Degree of protection
IP20
Min. degree of protection of inst. location
IP54
Control
one and two channel
Housing material
PBT
Housing color
yellow
6
04/14/2017 Page 3 / 6
https://www.phoenixcontact.com/us/products/2700525
Safety relays - PSR-MC32-3NO-1NC-24-230UC-SP - 2700525
Technical data
Connection data
Connection method
Spring-cage connection
pluggable
Yes
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
1.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
1.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
16
Stripping length
8 mm
Safety-related characteristic data
Stop category
0
Designation
IEC 61508 - High demand
Safety Integrity Level (SIL)
3
Designation
IEC 61508 - Low demand
Safety Integrity Level (SIL)
3
Designation
EN ISO 13849
Performance level (PL)
e
Category
4 (5 A DC13; 5 A AC15; 8760 switching cycles/year)
Safety Integrity Level Claim Limit (SIL CL)
3
Standards and Regulations
Shock
15g
Designation
Air clearances and creepage distances between the power circuits
Standards/regulations
DIN EN 50178; EN 60947-5-1
Rated insulation voltage
250 V AC
Rated surge voltage/insulation
Basic insulation 4 kV between enabling current path (23/24) and enabling
current path (33/34) and signaling current path (41/42)
Basic insulation 4 kV between all current paths and housing
Safe isolation, reinforced insulation 6 kV between all other circuits
Degree of pollution
2
Overvoltage category
III
Vibration (operation)
10 Hz ...150 Hz, 2g
Conformance
CE-compliant
Drawings
04/14/2017 Page 4 / 6
https://www.phoenixcontact.com/us/products/2700525
Safety relays - PSR-MC32-3NO-1NC-24-230UC-SP - 2700525
Block diagram
A1
S10 S11 S12 S13
PSR-MC32
IN 1/2
13 23 33 41
K1
PWR
K2
24...230V
AC / DC
A2
S21 S22 S34 S35
14 24 34 42
Circuit diagram
L
24-230V AC/DC
S1
A1
S11
(+)
S10
( )
S12
( )
S22 S21
( ) (GND)
S13
( )
13
23
33
41
K1
14
24
34
42
K2
PSR-MC32
A2
( )
( )
S34
S35
K1
S2
M
K1
K2
K2
M
(N)
Classifications
eCl@ss
eCl@ss 5.1
27371901
eCl@ss 6.0
27371819
eCl@ss 8.0
27371819
eCl@ss 9.0
27371819
ETIM
ETIM 3.0
EC001449
ETIM 4.0
EC001449
ETIM 5.0
EC001449
04/14/2017 Page 5 / 6
https://www.phoenixcontact.com/us/products/2700525
Safety relays - PSR-MC32-3NO-1NC-24-230UC-SP - 2700525
Classifications
UNSPSC
UNSPSC 13.2
39121501
Approvals
Approvals
Approvals
UL Listed / cUL Listed / Functional Safety / cULus Listed
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 140324
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 140324
44-205-15124310
Functional Safety
cULus Listed
Phoenix Contact 2017 © - all rights reserved