0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2700564

2700564

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
2700564 数据手册
https://www.phoenixcontact.com/us/products/2700564 Safety relays - PSR-MC50-3NO-1DO-24DC-SP - 2700564 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Safety relay for monitoring non-equivalent signal generators up to SILCL 3, Cat. 4, PL e, 2-channel, nonequivalent operation, automatic or manual, monitored start, 3 enabling current paths, US = 24 V DC, plug-in spring-cage terminal block The figure shows a version with a screw connection Why buy this product  Up to Cat.4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061  Low housing width of just 12.5 mm  Two-channel non-equivalent control  3 enabling current paths, 1 digital signal output  Manually monitored and automatic activation in a single device Key Commercial Data Packing unit 1 STK Weight per Piece (excluding packing) 180.000 g Custom tariff number 85371099 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 12.5 mm Height 116.6 mm Depth 114.5 mm 08/30/2016   Page 1 / 6 https://www.phoenixcontact.com/us/products/2700564 Safety relays - PSR-MC50-3NO-1DO-24DC-SP - 2700564 Technical data Ambient conditions Ambient temperature (operation) -40 °C ... 55 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing) Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing) Shock 15g Vibration (operation) 10 Hz ...150 Hz, 2g Maximum altitude ≤ 2000 m (Above sea level) Input data Rated control circuit supply voltage US 24 V DC -15 % / +10 % Power consumption at US typ. 1.92 W Rated control supply current IS typ. 80 mA Inrush current 5 A (Δt = 200 µs at Us) Current consumption < 5 mA (with Us/Ix to S12) < 5 mA (with Us/Ix to S13) > -5 mA (with Us/Ix to S34) < 10 mA (with Us/Ix to S34) Voltage at input/start and feedback circuit 24 V DC -15 % / +10 % Typical response time < 175 ms (automatic start) < 175 ms (manual, monitored start) Typ. starting time with Us < 250 ms (when controlled via A1) Typical release time < 20 ms (when controlled via A1 or S12 and S13.) Recovery time < 500 ms Status display 3 x green LED Maximum switching frequency 0.5 Hz Max. permissible overall conductor resistance 150 Ω Filter time 1 ms (at A1 in the event of voltage dips at Us) max. 1.5 ms (at S12, S13; test pulse width) min. 7.5 ms (at S12, S13; test pulse rate) Test pulse rate = 5 x Test pulse width Output data Contact type 3 enabling current paths Contact material AgSnO2 Minimum switching voltage 12 V AC/DC Maximum switching voltage 250 V AC/DC (Observe the load curve) Limiting continuous current 6 A (observe derating) Inrush current, minimum 3 mA 08/30/2016   Page 2 / 6 https://www.phoenixcontact.com/us/products/2700564 Safety relays - PSR-MC50-3NO-1DO-24DC-SP - 2700564 Technical data Output data Maximum inrush current 6A Sq. Total current 48 A (observe derating) Switching capacity min. 60 mW Output fuse 6 A gL/gG (N/O contact) 2 4 A gL/gG (for low-demand applications) Alarm outputs Number of outputs 1 (digital, PNP) Voltage 22 V DC (Us - 2 V) Current max. 100 mA Maximum inrush current 500 mA (Δt = 1 ms at Us) Short-circuit protection no General Relay type Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) Mechanical service life 10 x 10 cycles Nominal operating mode 100% operating factor Net weight 177.4 g Mounting type DIN rail mounting Assembly instructions See derating curve Mounting position vertical or horizontal Degree of protection IP20 Min. degree of protection of inst. location IP54 Control Two-channel Housing material PBT Housing color yellow 6 Connection data Connection method Spring-cage connection pluggable Yes Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm 08/30/2016   Page 3 / 6 https://www.phoenixcontact.com/us/products/2700564 Safety relays - PSR-MC50-3NO-1DO-24DC-SP - 2700564 Technical data Safety-related characteristic data Stop category 0 Designation IEC 61508 - High demand Safety Integrity Level (SIL) 3 Designation IEC 61508 - Low demand Safety Integrity Level (SIL) 3 Designation EN ISO 13849 Performance level (PL) e (4 A DC13; 5 A AC15; 8760 switching cycles/year) Category 4 Designation EN 62061 Safety Integrity Level Claim Limit (SIL CL) 3 Standards and Regulations Shock 15g Designation Air clearances and creepage distances between the power circuits Standards/regulations DIN EN 50178 Rated insulation voltage 250 V AC Rated surge voltage/insulation Safe isolation, reinforced insulation 6 kV between input circuit and enabling current path (13/14) and enabling current path (23/24) and enabling current path (33/34) Basic insulation 4 kV between all current paths and housing Degree of pollution 2 Overvoltage category III Vibration (operation) 10 Hz ...150 Hz, 2g Drawings Block diagram A1 S12 S13 PSR-MC50 S34 IN 1/2 Block diagram 13 23 33 PSR-MC50 A1 13 23 33 S13 S34 K1 1 PWR 3 2 K2 K1 K2 K3 K4 K5 K6 K1 K2 24V DC A2 M1 14 24 34 8 5 4 K3 9 K4 K5 K6 7 6 8 A2 S12 M1 14 24 34 Key: 1 = Input circuit 2 = Voltage limitation 3 = Start circuit 08/30/2016   Page 4 / 6 https://www.phoenixcontact.com/us/products/2700564 Safety relays - PSR-MC50-3NO-1DO-24DC-SP - 2700564 4 = Control circuit channel 1 5 = Control circuit signal output 6 = Control circuit channel 2 7 = Start channel 1 and 2 8 = Channel 1 9 = Diagnostics K1, K2 ... K6 = Force-guided elementary relays Circuit diagram 24V DC L S3 S2 K1 11 12 13 14 K2 A1 S34 ( ) S12 S13 ( ) ( ) 13 23 33 14 24 34 K1 PSR-MC50 ( ) A2 M1 K2 M K1 K2 0V N Classifications eCl@ss eCl@ss 5.1 27371901 eCl@ss 6.0 27371819 eCl@ss 8.0 27371819 eCl@ss 9.0 27371819 ETIM ETIM 5.0 EC001449 Approvals Approvals Approvals UL Listed / cUL Listed / EAC / Functional Safety / cULus Listed Ex Approvals Approval details 08/30/2016   Page 5 / 6 https://www.phoenixcontact.com/us/products/2700564 Safety relays - PSR-MC50-3NO-1DO-24DC-SP - 2700564 Approvals UL Listed  cUL Listed   http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 140324  http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 140324 EAC   7500651.22.01.00244 Functional Safety   44-205-13755201 cULus Listed    Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 08/30/2016   Page 6 / 6
2700564 价格&库存

很抱歉,暂时无法提供与“2700564”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2700564
  •  国内价格 香港价格
  • 1+1673.699521+208.35988

库存:1