0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2701212

2701212

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    INPUT MODULE 8 DIGITAL 24V

  • 数据手册
  • 价格&库存
2701212 数据手册
IB IL 24 DI8/HD-XC-PAC Inline digital input terminal, version for extreme conditions, 8 inputs, 24 V DC Data sheet 8461_en_00 1 © PHOENIX CONTACT 2012-05-29 Description The terminal block has been developed for use in an Inline station. It is used to acquire digital signals. Thanks to special engineering measures and tests, the terminal can be used under extreme ambient conditions. Features – – – – – – Connections for eight digital sensors Connection of sensors in 1-wire technology Diagnostic and status indicators Can be used under extreme ambient conditions Painted PCBs Extended temperature range T2 (-40°C  +55°C)   This data sheet is only valid in association with the IL SYS INST UM E user manual. Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/catalog. IB IL 24 DI8/HD-XC-PAC 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 3 5 Additional tables ...................................................................................................................... 5 6 Tested successfully: Use under extreme ambient conditions .................................................. 6 7 Internal circuit diagram ............................................................................................................ 6 8 Local status and diagnostic indicators ..................................................................................... 7 9 Terminal point assignment....................................................................................................... 7 10 Connection notes and examples ............................................................................................. 7 11 Process data............................................................................................................................ 7 8461_en_00 PHOENIX CONTACT 2 IB IL 24 DI8/HD-XC-PAC 3 Ordering data Description Type Order No. Pcs. / Pkt. Inline digital input terminal, version for extreme conditions, complete with accessories (connector plug and labeling field), 8 inputs, 24 V DC, 1-wire connection technology IB IL 24 DI8/HD-XC-PAC 2701212 1 Accessories Type Order No. Pcs. / Pkt. Connector, for digital 1, 2 or 8-channel Inline terminals ( Plug/Adapter ) IB IL SCN-8 2726337 10 Labeling field, width: 12.2 mm ( Marking ) IB IL FIELD 2 2727501 10 Documentation Type Order No. Pcs. / Pkt. User manual, English, Automation terminals of the Inline product range IL SYS INST UM E - - Data sheet, English, INTERBUS addressing DB GB IBS SYS ADDRESS - - 4 Technical data Dimensions (nominal sizes in mm) 140,5 71,5 119,8 Width 12.2 mm Height 119.8 mm Depth 71.5 mm Note on dimensions Housing dimensions General data Color green Weight 60 g   ( With connector ) Operating mode Process data mode with one byte Ambient temperature (operation) -40 °C ... 55 °C (See also the "Tested successfully: Use under extreme ambient conditions" section of the data sheet.) Ambient temperature (operation) -40 °C ... 60 °C (At US < 24.5 V; see also the "Tested successfully: Use under extreme ambient conditions" section of the data sheet.) Ambient temperature (storage/transport) -40 °C ... 85 °C Temperature class T2 (-40°C ... 55°C, EN 50155) Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) 8461_en_00 PHOENIX CONTACT 3 IB IL 24 DI8/HD-XC-PAC General data Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Connection data Name Inline connectors Connection method Spring-cage connection Conductor cross section solid / stranded 0.08 mm²   ...   1.5 mm² Conductor cross section [AWG] 28   ...   16 Interface Inline local bus Connection method Inline data jumper Transmission speed 500 kBit/s Power consumption Segment supply voltage US 24 V DC (nominal value) Current consumption from US max. 5.5 mA DC Communications power UL 7.5 V DC Current consumption from UL max. 30 mA DC Power loss max. 0.72 W Digital inputs Number of inputs 8 Connection method Spring-cage connection Connection method 1-wire Description of the input EN 61131-2 types 1 and 3 Nominal input voltage 24 V DC Nominal input current Typ. 2.4 mA Input voltage range "0" signal -3 V DC ... 5 V DC Input voltage range "1" signal 11 V DC ... 30 V DC Delay at signal change from 0 to 1 1 ms Delay at signal change from 1 to 0 1 ms Permissible conductor length to the sensor 30 m Programming Data ID code (hex) BE ID code (dec.) 190 Length code (hex) 81 Length code (dec.) 129 Process data channel 8 Bit Input address area 1 Byte Output address area 0 Byte Parameter channel (PCP) 0 Byte Register length (bus) 8 Bit For the programming data/configuration data of other bus systems, please refer to the corresponding electronic device data sheet (e.g., GSD, EDS). PROFIBUS telegram data Required parameter data 1 Byte Need for configuration data 4 Byte 8461_en_00 PHOENIX CONTACT 4 IB IL 24 DI8/HD-XC-PAC Error messages to the higher level control or computer system None Electrical isolation/isolation of the voltage areas 5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V AC , 50 Hz , 1 min 5 V supply, outgoing remote bus/7.5 V supply (bus logics) 500 V AC , 50 Hz , 1 min 7.5 V supply (bus logics)/24 V supply (I/O) 500 V AC , 50 Hz , 1 min 24 V supply (I/O) / functional earth ground 500 V AC , 50 Hz , 1 min To achieve electrical isolation between the logic level and the I/O area, supply these areas from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted (see also user manual). Approvals For the latest approvals, please visit www.phoenixcontact.net/catalog. 5 Additional tables Input characteristic curve Input voltage U [V] Typical input current I [mA] -30 < U ≤ 0.7 0 3 0.12 6 1.32 9 2.32 12 2.36 15 2.36 18 2.36 21 2.36 24 2.40 27 2.40 30 2.40 8461_en_00 PHOENIX CONTACT 5 IB IL 24 DI8/HD-XC-PAC 6 Tested successfully: Use under extreme ambient conditions 7 Internal circuit diagram The terminal has been tested successfully over 250 temperature change cycles in accordance with IEC 61131-2 in the range from -40°C to +70°C.   Local bus The following conditions were observed: – The Inline devices for all connecting cables were connected with a minimum conductor cross section of 0.5 mm² – The Inline station was assembled on a wall-mounted horizontal DIN rail – Fans were used to ensure continuous movement of air in the control cabinet – The Inline station was not exposed to vibration or shock – The Inline station was operated with a maximum of 24.5 V (ensured by using regulated power supply units) OPC UL 8 4x 16 8 4x 3 h + 30 min t1 Tmax + 2 K +24 V (US) +24 V (UM) (3 + 0,6) K/min Tmin + 3 K 3 h + 30 min t1 1 Figure 1 Figure 2 Internal wiring of the terminal points Temperature change cycle Temperature in the control cabinet/ambient temperature OPC Protocol chip (Bus logic including voltage conditioning) LED (status indicator) Cycle Optocoupler WARNING: Digital input The terminal is not approved for use in potentially explosive areas. The terminal is not approved for use in safety technology. 8461_en_00 Explanation for other used symbols has been provided in the IL SYS INST UM E user manual. PHOENIX CONTACT 6 IB IL 24 DI8/HD-XC-PAC 8 Local status and diagnostic indicators 10 Connection notes and examples NOTE: Malfunction Make sure that the supply voltage US is available, as it is used internally as the auxiliary voltage. D 1 3 5 7 2 4 6 8 Figure 3 When connecting the sensors observe the assignment of the terminal points to the process data. Local status and diagnostic indicators NOTE: Malfunction Designation D 1 to 8 Color Meaning The sensors and US must be supplied from the same voltage supply. Green Yellow Diagnostics (bus and logic voltage) Status of the inputs If you connect the sensors via external busbars, make sure that the sensors and US are supplied by the same power supply. Function identification Light blue 9 Terminal point assignment 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 IN2 IN1 +24 V 1.1 1.1 2.1 2.1 1.2 1.2 2.2 2.2 1.3 1.3 2.3 2.3 1.4 1.4 2.4 2.4 +24 V IN7 +24 V IN8 +24 V +24 V Figure 5 11 Example of a connection of sensors when using external busbars Process data Assignment of the terminal points to IN process data Figure 4 Terminal point assignment Terminal point 1.1 / 2.1 1.2 / 2.2 1.3 / 2.3 1.4 / 2.4 Assignment Signal input (IN 1 / IN 2) Signal input (IN 3 / IN 4) Signal input (IN 5 / IN 6) Signal input (IN 7 / IN 8) (Byte.Bit) Byte view Bit AssignTermiment nal point (signal) Status in- LED dicator Byte 0 7 6 5 4 3 2 1 0 2.4 1.4 2.3 1.3 2.2 1.2 2.1 1.1 8 7 6 5 4 3 2 1 For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet. 8461_en_00 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany www.phoenixcontact.com 7
2701212 价格&库存

很抱歉,暂时无法提供与“2701212”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2701212

    库存:0