0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2701213

2701213

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    OUTPUT MODULE 8 SOLID STATE 24V

  • 数据手册
  • 价格&库存
2701213 数据手册
IB IL 24 DO8/HD-XC-PAC Inline digital output terminal, version for extreme conditions, 8 outputs, 24 V DC, 500 mA Data sheet 8462_en_00 1 © PHOENIX CONTACT 2012-05-29 Description The terminal is designed for use within an Inline station. It is used to output digital signals. Thanks to special engineering measures and tests, the terminal can be used under extreme ambient conditions. Features – – – – – – – – – Connections for eight digital actuators Connection of actuators in 1-wire technology Nominal current per output: 0.5 A Total current of the terminal: 4 A Short-circuit and overload protected outputs Diagnostic and status indicators Can be used under extreme ambient conditions Painted PCBs Extended temperature range T2 (-40°C  +55°C)   This data sheet is only valid in association with the IL SYS INST UM E user manual. Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/catalog. IB IL 24 DO8/HD-XC-PAC 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 3 5 Additional tables ...................................................................................................................... 6 6 Tested successfully: Use under extreme ambient conditions .................................................. 6 7 Internal circuit diagram ............................................................................................................ 7 8 Local status and diagnostic indicators ..................................................................................... 7 9 Terminal point assignment....................................................................................................... 8 10 Connection notes and examples ............................................................................................. 8 11 Process data............................................................................................................................ 8 8462_en_00 PHOENIX CONTACT 2 IB IL 24 DO8/HD-XC-PAC 3 Ordering data Description Type Order No. Pcs. / Pkt. Inline digital output terminal, version for extreme conditions, complete with accessories (connector plug and labeling field), 8 outputs, 24 V DC, 500 mA, 1-wire connection technology IB IL 24 DO8/HD-XC-PAC 2701213 1 Accessories Type Order No. Pcs. / Pkt. Connector, for digital 1, 2 or 8-channel Inline terminals ( Plug/Adapter ) IB IL SCN-8 2726337 10 Labeling field, width: 12.2 mm ( Marking ) IB IL FIELD 2 2727501 10 Documentation Type Order No. Pcs. / Pkt. User manual, English, Automation terminals of the Inline product range IL SYS INST UM E - - Data sheet, English, INTERBUS addressing DB GB IBS SYS ADDRESS - - 4 Technical data Dimensions (nominal sizes in mm) 140,5 71,5 119,8 Width 12.2 mm Height 119.8 mm Depth 71.5 mm Note on dimensions Housing dimensions General data Color green Weight 60 g   ( With connector ) Operating mode Process data mode with one byte Ambient temperature (operation) -40 °C ... 55 °C (See also the "Tested successfully: Use under extreme ambient conditions" section of the data sheet.) Ambient temperature (operation) -40 °C ... 60 °C (At US < 24.5 V; see also the "Tested successfully: Use under extreme ambient conditions" section of the data sheet.) Ambient temperature (storage/transport) -40 °C ... 85 °C Temperature class T2 (-40°C ... 55°C, EN 50155) Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) 8462_en_00 PHOENIX CONTACT 3 IB IL 24 DO8/HD-XC-PAC General data Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Connection data Name Inline connectors Connection method Spring-cage connection Conductor cross section solid / stranded 0.08 mm²   ...   1.5 mm² Conductor cross section [AWG] 28   ...   16 Interface Inline local bus Connection method Inline data jumper Transmission speed 500 kBit/s Power consumption Segment supply voltage US 24 V DC (nominal value) Current consumption from US max. 4 A DC Communications power UL 7.5 V DC Current consumption from UL max. 45 mA Power loss max. 0.62 W Digital outputs Number of outputs 8 Connection method Spring-cage connection Connection method 1-wire Output voltage 24 V (US - 1 V) Maximum output current per channel 500 mA Maximum output current per device 4A Nominal load, ohmic 12 W (48 Ω) Nominal load, inductive 12 VA (1.2 H; 50 Ω) Nominal load, lamp 12 W Signal delay when switching on an ohmic nominal load Typ. 500 µs Signal delay when switching on an inductive nominal load Typ. 100 ms (1.2 H; 50 Ω) Signal delay when switching on a lamp nominal load Typ. 100 ms Signal delay when switching off an ohmic nominal load Typ. 1 ms Signal delay when switching off an inductive nominal load Typ. 50 ms (1.2 H; 50 Ω) Signal delay when switching off a lamp nominal load Typ. 1 ms Maximum operating frequency with ohmic nominal load max. 300 Hz (this switching frequency is limited by the data rate selected, the number of bus devices, the structure of the bus, the software used and the control or computer system used) Maximum operating frequency with inductive nominal load max. 0.5 Hz Maximum operating frequency with lamp nominal load max. 8 Hz (this switching frequency is limited by the data rate selected, the number of bus devices, the structure of the bus, the software used and the control or computer system used) Reaction time with short-circuit ca. 1 s Reaction time with ohmic overload ca. 3 s Behavior at voltage switch-off The output follows the power supply without delay One-time unsolicited energy 300 mJ Limitation of the voltage induced on circuit interruption -15 V ≤ Udemag ≤ -45.8 V (Udemag = demagnetization voltage) Output voltage when switched off max. 1 V Output current when switched off max. 300 µA Behavior with overload Auto restart 8462_en_00 PHOENIX CONTACT 4 IB IL 24 DO8/HD-XC-PAC Digital outputs Restart frequency with ohmic overload 400 Hz Restart frequency with lamp overload 400 Hz Behavior with inductive overload Output can be destroyed Reverse voltage resistance to short pulses Reverse voltage proof Resistance to permanent reverse voltage max. 500 mA Overcurrent shut-down min. 0.7 A Overload protection, short-circuit protection of outputs Zener diode in output chip Programming Data ID code (hex) BD ID code (dec.) 189 Length code (hex) 81 Length code (dec.) 129 Process data channel 8 Bit Input address area 0 Bit Output address area 8 Bit Parameter channel (PCP) 0 Bit Register length (bus) 8 Bit For the programming data/configuration data of other bus systems, please refer to the corresponding electronic device data sheet (e.g., GSD, EDS). PROFIBUS telegram data Required parameter data 3 Byte Need for configuration data 4 Byte Error messages to the higher level control or computer system Short-circuit / overload of the digital outputs Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module Electrical isolation/isolation of the voltage areas 5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V AC , 50 Hz , 1 min 5 V supply, outgoing remote bus/7.5 V supply (bus logics) 500 V AC , 50 Hz , 1 min 7.5 V supply (bus logics)/24 V supply (I/O) 500 V AC , 50 Hz , 1 min 24 V supply (I/O) / functional earth ground 500 V AC , 50 Hz , 1 min To achieve electrical isolation between the logic level and the I/O area, supply these areas from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted (see also user manual). Approvals For the latest approvals, please visit www.phoenixcontact.net/catalog. 8462_en_00 PHOENIX CONTACT 5 IB IL 24 DO8/HD-XC-PAC 5 Additional tables Output characteristic curve when switched on (typical) Output current (A) Differential output voltage (V) 0 0 0.1 0.02 0.2 0.03 0.3 0.04 0.4 0.06 0.5 0.07 6 Tested successfully: Use under extreme ambient conditions The terminal has been tested successfully over 250 temperature change cycles in accordance with IEC 61131-2 in the range from -40°C to +70°C.   The following conditions were observed: – The Inline devices for all connecting cables were connected with a minimum conductor cross section of 0.5 mm² – The Inline station was assembled on a wall-mounted horizontal DIN rail – Fans were used to ensure continuous movement of air in the control cabinet – The Inline station was not exposed to vibration or shock – The Inline station was operated with a maximum of 24.5 V (ensured by using regulated power supply units) 3 h + 30 min t1 Tmax + 2 K (3 + 0,6) K/min Tmin + 3 K 3 h + 30 min t1 1 Figure 1 Temperature change cycle Temperature in the control cabinet/ambient temperature Cycle WARNING: The terminal is not approved for use in potentially explosive areas. The terminal is not approved for use in safety technology. 8462_en_00 PHOENIX CONTACT 6 IB IL 24 DO8/HD-XC-PAC 7 Internal circuit diagram Local bus 8 OPC UL 16 8 Explanation for other used symbols has been provided in the IL SYS INST UM E user manual. Local status and diagnostic indicators 8 D 4x 4x 1 3 5 7 2 4 6 8 Figure 3 Local status and diagnostic indicators US +24 V (US) +24 V (UM) Designation D 1 to 8 Color Meaning green Yellow Diagnostics (bus and logic voltage) Status of the outputs Function identification Pink Figure 2 Internal wiring of the terminal points Key: Explanation for other used symbols has been provided in the IL SYS INST UM E user manual. OPC Protocol chip (Bus logic including voltage conditioning) LED (status indicator) Optocoupler Transistor Digital output 8462_en_00 PHOENIX CONTACT 7 IB IL 24 DO8/HD-XC-PAC 9 Terminal point assignment Figure 4 1.1 1.1 2.1 2.1 1.2 1.2 2.2 2.2 1.3 1.3 2.3 2.3 1.4 1.4 2.4 2.4 10 Connection notes and examples When connecting the actuators, observe the assignment of the terminal points to the process data. NOTE: Malfunction GND of the actuators and GND of the supply voltage US, which supply the actuators, must have the same potential. If you connect the actuators via external busbars, make sure that the GND of the actuators and the GND for US have the same potential. Terminal point assignment Terminal point 1.1 / 2.1 1.2 / 2.2 1.3 / 2.3 1.4 / 2.4 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 OUT2 OUT1 Assignment Signal output (OUT 1 / OUT 2) Signal output (OUT 3 / OUT 4) Signal output (OUT 5 / OUT 6) Signal output (OUT 7 / OUT 8) OUT7 Figure 5 11 OUT8 Typical connection of actuators when using external busbars Process data Assignment of the terminal points to the output process data (Byte.Bit) Byte view Bit AssignTermiment nal point (signal) Status in- LED dicator Byte 0 7 6 5 4 3 2 1 0 2.4 1.4 2.3 1.3 2.2 1.2 2.1 1.1 8 7 6 5 4 3 2 1 For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet. 8462_en_00 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany www.phoenixcontact.com 8
2701213 价格&库存

很抱歉,暂时无法提供与“2701213”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2701213
    •  国内价格 香港价格
    • 1+1222.184751+152.86731

    库存:3

    2701213
      •  国内价格
      • 1+1021.21211

      库存:1