IB IL 24/48 DOR 2/W-XC-PAC
Inline digital output terminal, version for extreme
conditions, 2 relay PDTs
Data sheet
8463_en_01
1
© PHOENIX CONTACT 2015-08-12
Description
The terminal is designed for use within an Inline station.
It has two floating relay PDTs which are independent of
each other.
Thanks to special engineering measures and tests, the terminal can be used under extreme ambient conditions.
Features
–
–
–
–
–
–
–
–
–
Two relay outputs
Floating connections for 2 actuators
Nominal current of each output: 2 A
Total current of the terminal: 4 A
Segment voltage US connected
Diagnostic and status indicators
Can be used under extreme ambient conditions
Extended temperature range of -40°C ... +70°C
(see “Tested successfully: use under extreme ambient
conditions”)
Painted PCBs
WARNING: Undefined system state
By default, the position of the relay contacts on the module is not defined. To prevent undesired system states,
perform a complete cycle (on/off) before connecting the segment voltage.
This data sheet is only valid in association with the IL SYS INST UM E user manual.
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
IB IL 24/48 DOR 2/W-XC-PAC
2
Table of contents
1
Description .............................................................................................................................. 1
2
Table of contents ..................................................................................................................... 2
3
Ordering data .......................................................................................................................... 3
4
Technical data ......................................................................................................................... 3
5
Additional tables ...................................................................................................................... 6
5.1
Maximum switching current for ohmic load depending on the switching voltage................................... 6
5.2
Power dissipation ................................................................................................................ 6
5.3
Limitation of simultaneity, derating ........................................................................................... 7
5.4
Air clearances and creepage distances ..................................................................................... 7
6
Tested successfully: Use under extreme ambient conditions .................................................. 8
7
Internal circuit diagram ............................................................................................................ 9
8
Special features of the terminal ............................................................................................... 9
8.1
Switching a voltage equal to the segment voltage ........................................................................ 9
8.2
Switching a voltage unequal to the segment voltage ..................................................................... 9
9
Local status and diagnostic indicators ................................................................................... 10
10
Terminal point assignment..................................................................................................... 10
11
Connection notes and examples ........................................................................................... 11
12
Process data.......................................................................................................................... 11
8463_en_01
PHOENIX CONTACT
2
IB IL 24/48 DOR 2/W-XC-PAC
3
Ordering data
Description
Type
Order No.
Pcs./Pkt.
Inline digital output terminal, version for extreme conditions, complete with
accessories (connector plug and labeling field), 2 relay PDTs, gold contact, 5 - 48 V DC, 2 A
IB IL 24/48 DOR 2/W-XC-PAC
2701214
1
Accessories
Type
Order No.
Pcs./Pkt.
Labeling field, width: 12.2 mm (Marking)
IB IL FIELD 2
2727501
10
Insert strip, Sheet, white, unlabeled, can be labeled with: Office printing
systems, Plotter: Laser printer, Mounting type: Insert, Lettering field: 62 x
10 mm (Marking)
ESL 62X10
0809492
1
Connector, for digital 1, 2 or 8-channel Inline terminals (Connector/
Adapter)
IB IL SCN-8
2726337
10
Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: Plotter,
Mounting type: Snap into flat marker groove, for terminal block width: 6.2
mm, Lettering field: 5.15 x 6.15 mm (Marking)
ZBF 6:UNBEDRUCKT
0808710
10
Zack Marker strip, flat, white, for terminal block width: 6.2 mm (Marking)
ZBF 6:SO/CMS
0808778
1
Flat zack marker sheet, white, for terminal block width: 6.2 mm (Marking)
ZBFM 6:SO/CMS
0803650
1
Flat zack marker sheet, Sheet, white, unlabeled, can be labeled with: Plot- ZBFM 6/WH:UNBEDRUCKT
ter, Mounting type: Snap into flat marker groove, for terminal block width:
6.2 mm, Lettering field: 5 x 5.5 mm (Marking)
0803618
10
Inline distance terminal, complete with accessories
IB IL DOR LV-SET-PAC
2861645
1
Documentation
Type
Order No.
Pcs./Pkt.
Application note, English,
The safety-related segment circuit
AH EN IL SAFE
-
-
Data sheet, English, INTERBUS addressing
DB GB IBS SYS ADDRESS
-
-
Application note, English,
Using distance terminal blocks and interference suppression measures on
inductive loads
AH EN IB IL DOR
-
-
4
Technical data
Dimensions (nominal sizes in mm)
140,5
71,5
119,8
Width
12.2 mm
Height
119.8 mm
Depth
71.5 mm
Note on dimensions
Housing dimensions
8463_en_01
PHOENIX CONTACT
3
IB IL 24/48 DOR 2/W-XC-PAC
General data
Color
green
Weight
63 g (with connector)
Operating mode
Process data mode with 2 bits
Ambient temperature (operation)
-25 °C ... 55 °C (Standard)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme
ambient conditions” in the data sheet.)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)
10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protection
IP20
Protection class
III, IEC 61140, EN 61140, VDE 0140-1
Connection data
Designation
Inline connector
Connection method
Spring-cage connection
Conductor cross section solid / stranded
0.08 mm² ... 1.5 mm² / 0.08 mm² ... 1.5 mm²
Conductor cross section [AWG]
28 ... 16
Stripping length
8 mm
Interface Inline local bus
Connection method
Inline data jumper
Transmission speed
500 kBit/s
Power consumption
Communications power UL
7.5 V DC
Current consumption from UL
max. 30 mA
Power consumption
0.23 W (at UL)
Relay output
Number of outputs
2
Connection method
Spring-cage connection
Connection method
Floating SPDT relay contact
Nominal output voltage
48 V DC
Output voltage range
5 V AC ... 30 V AC
5 V DC ... 60 V DC
Maximum output current per channel
2A
Contact type
2 floating PDT contacts
Contact material
AgSnO2, hard gold-plated
Contact resistance
75 mΩ
Switching voltage
min. 10 mV (DC)
max. 30 V AC (PELV (EN 61131))
max. 60 V DC (PELV (EN 61131))
Switching current
min. 10 µA
2 A (30 V DC)
1 A (60 V DC)
Limiting continuous current
2 A (at maximum ambient temperature)
Switching capacity
60 W
62.5 VA (ohmic)
Switching frequency
1 Hz (without load) ; 1 Hz (with load)
Nominal power consumption
200 mW
8463_en_01
PHOENIX CONTACT
4
IB IL 24/48 DOR 2/W-XC-PAC
Relay output
Coil resistance
178 Ω ±10 % (at 20 °C)
Typical response time
typ. 20 ms
Bouncing time
4 ms (for on and off)
Typical release time
typ. 20 ms
Service life, electrical
108 cycles
Mechanical service life
2x 105 cycles
Common potentials
all contacts floating
Programming data (INTERBUS, local bus)
ID code (hex)
BD
ID code (dec.)
189
Length code (hex)
2C
Length code (dec.)
44
Process data channel
2 Bit
Input address area
0 Bit
Output address area
2 Bit
Parameter channel (PCP)
0 Bit
Register length (bus)
2 Bit
For the programming data/configuration data of other bus systems, please refer to the corresponding electronic device data sheet (e.g., GSD,
EDS).
Configuration and parameter data in a PROFIBUS system
Required parameter data
3 Byte
Need for configuration data
4 Byte
Error messages to the higher level control or computer system
None
Electrical isolation/isolation of the voltage areas
Test section
Test voltage
Relay contact / Bus logics
1.5 kV, 50 Hz, 1 min
Contact/contact
1 kV, 50 Hz, 1 min
Contact / PE
1 kV, 50 Hz, 1 min
To achieve electrical isolation between the logic level and the I/O area, supply these areas from separate power supply units. Interconnection
of the power supply units in the 24 V area is not permitted (see also user manual).
Approvals
For the latest approvals, please visit phoenixcontact.net/products.
8463_en_01
PHOENIX CONTACT
5
IB IL 24/48 DOR 2/W-XC-PAC
5
Additional tables
5.1
Maximum switching current for ohmic load depending on the switching voltage
5.2
Power dissipation
Formula for calculating the power dissipation of the
electronics
Switching voltage (V DC) Switching current (A)
10
2.0
20
2.0
30
2.0
60
1.0
Load current IL as a function of the switching voltage
US
3,0
A
2,0
IL
1
1,0
2
n
PEL = 0,23 W + m x 0,14W + ∑ (ILi2 x 0,075)
i=1
Where:
PEL
i
n
m
ILi
Total power dissipation in the terminal
Continuous index
Number of set outputs (n = 1 ... 2)
Number of relays with controlled coil
Load current of output i
Power dissipation of the housing
0,3
0,1
10
30
Figure 1
1
2
US
100 V 200
Load current IL as a function of the switching
voltage US
DC, ohmic load
AC, ohmic load
PHOU = 1.2 W
-25°C ≤ TA