2701298

2701298

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    POWER SUPPLY MODULE 24V

  • 数据手册
  • 价格&库存
2701298 数据手册
IB IL 24 PWR IN/R-XC-PAC Inline power/boost terminal version for extreme conditions, 24 V DC, without fuse Data sheet 8499_en_01 1 © PHOENIX CONTACT 2014-12-17 Description The terminal is designed for use within an Inline station. If the maximum load of the bus coupler for the communications power (UL) or the supply voltage for the analog terminals (UANA) is reached, this terminal can be used to provide these voltages again. To this end, a 24 V DC voltage (U24V) is applied to the terminal from which the communications power (UL) and the supply voltage for the analog terminals (UANA) is generated. The terminal also allows the 24 V DC main voltage (UM) and the 24 V DC segment voltage (US) to be supplied. Thanks to special engineering measures and tests, the terminal can be used under extreme ambient conditions. Features – – – – – Supply of all 24 V voltages required for the low-level signal of an Inline station Diagnostic indicators Can be used under extreme ambient conditions Extended temperature range of -40°C ... +70°C (see “Tested successfully: use under extreme ambient conditions”) Painted PCBs This data sheet is only valid in association with the IL SYS INST UM E user manual. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. IB IL 24 PWR IN/R-XC-PAC 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 3 5 Electrical isolation/isolation of the voltage areas...................................................................... 5 6 Tested successfully: Use under extreme ambient conditions .................................................. 6 7 Internal circuit diagram ............................................................................................................ 7 8 Terminal point assignment....................................................................................................... 8 9 Local diagnostic indicators ...................................................................................................... 9 10 Connection example................................................................................................................ 9 8499_en_01 PHOENIX CONTACT 2 IB IL 24 PWR IN/R-XC-PAC 3 Ordering data Description Type Order No. Pcs. / Pkt. Inline power terminal or boost terminal, version for extreme conditions, complete with accessories (connector connector and labeling field), 24 V DC, without fuse IB IL 24 PWR IN/R-XC-PAC 2701298 1 Accessories Type Order No. Pcs. / Pkt. Connector set, for power terminal block, copper, colored identification. (Connector/Adapter) IB IL PWR IN/R-PLSET 2860620 1 10 Labeling field, width: 12.2 mm (Marking) IB IL FIELD 2 2727501 Labeling field, width: 48.8 mm (Marking) IB IL FIELD 8 2727515 10 Insert strip, Sheet, white, unlabeled, can be labeled with: Office printing systems, Plotter: Laser printer, Mounting type: Insert, Lettering field: 62 x 10 mm (Marking) ESL 62X10 0809492 1 Documentation Type Order No. Pcs. / Pkt. User manual, English, Automation terminals of the Inline product range IL SYS INST UM E - - 4 Technical data Dimensions (nominal sizes in mm) 140,5 71,5 119,8 Width 48.8 mm Height 119.8 mm Depth 71.5 mm General data Color green Weight 192 g (with connectors) Mounting type DIN rail Ambient temperature (operation) -25 °C ... 55 °C Ambient temperature (operation) -40 °C ... 70 °C (See “Tested successfully: use under extreme ambient conditions” in the data sheet.) Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) 8499_en_01 PHOENIX CONTACT 3 IB IL 24 PWR IN/R-XC-PAC General data Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Connection data Designation Inline connector Connection method Spring-cage connection Conductor cross section solid / stranded 0.08 mm² ... 1.5 mm² / 0.08 mm² ... 1.5 mm² Conductor cross section [AWG] 28 ... 16 Stripping length 8 mm Connection data for UL approvals Designation Inline connector Connection method Spring-cage connection Conductor cross section solid / stranded 0.2 mm² ... 1.5 mm² / 0.2 mm² ... 1.5 mm² Conductor cross section [AWG] 24 ... 16 Stripping length 8 mm Interface Inline local bus Connection method Inline data jumper Transmission speed 500 kBit/s / 2 MBit/s (Can be used in Inline stations with these transmission speeds) Power consumption NOTE: Electronics may be damaged when overloaded Provide external fuses for each 24 V area. The power supply unit must be able to supply four times the nominal current of the external fuse, to ensure that it blows in the event of an error. When supply voltages UM/US are supplied separately from the supply voltage U24V, they are electrically isolated from one another. This is only ensured if two separate power supply units are used. 24 V supply (U24V) for generating UL and UANA 24 V DC Supply voltage range U24V 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Current consumption min. 12 mA DC (from U24V, at nominal voltage) max. 1.25 A DC (from U24V, at nominal voltage; consisting of: 0.75 A DC for the communications power and 0.5 A DC for the analog voltage supply) Main circuit supply UM 24 V DC Supply voltage range UM 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Power supply at UM max. 8 A (Sum of UM + US) Segment supply voltage US 24 V DC Supply voltage range US 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Power supply at US max. 8 A DC (Sum of UM + US) Communications power UL 7.5 V DC ±5 % (via voltage jumper) Power supply at UL max. 2 A DC I/O supply voltage UANA 24 V DC Supply voltage range UANA 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Power supply at UANA max. 0.5 A DC Power loss Power loss 8499_en_01 max. 2.55 W (entire device) PHOENIX CONTACT 4 IB IL 24 PWR IN/R-XC-PAC Configuration and parameter data in a PROFIBUS system Required parameter data 0 Byte Need for configuration data 0 Byte Electrical isolation/isolation of the voltage areas Test section Test voltage 7.5 V logics supply, 24 V analog supply/functional earth ground 500 V AC , 50 Hz , 1 min 7.5 V logics supply, 24 V analog supply, 24 V main supply, 24 V segment supply 500 V AC , 50 Hz , 1 min 24 V main supply, 24 V segment supply / functional earth ground 500 V AC , 50 Hz , 1 min Error messages to the higher level control or computer system None Protective circuit Surge protection (segment supply, main supply, 24 V supply) Input protective diodes (can be destroyed by permanent overload) Pulse loads up to 1500 W are short circuited by the input protective diode. Polarity reversal (segment supply/main supply) Parallel diodes for protection against polarity reversal; in the event of an error the high current flowing through the diodes causes the fuse connected upstream to blow. Polarity reversal (24 V supply) Serial diode in the lead path of the power supply unit; in the event of an error only a low current flows. In the event of an error, no fuse trips within the external power supply unit. If you want to protect the 24 V supply, use a 2 A medium-blow fuse. Approvals For the latest approvals, please visit phoenixcontact.net/products. 5 Electrical isolation/isolation of the voltage areas Common potentials When providing the 24 V supply for generating UL and UANA Main and segment supply have the same potential. From the separately from the 24 V main supply/24 V segment supply power terminal onwards, common ground is led through the potential jumper to the devices as reference ground GND. 24 V supply for generating UL and UANA, 24 V analog supply UANA, and 7.5 V communications power UL have the same potential. From the bus coupler onwards, common ground is led through the potential jumper to the devices as the reference ground "Logical GND" (UL-). When providing the 24 V supply for generating UL and UANA Main supply, segment supply, 24 V analog supply, and 7.5 V by jumpering the 24 V main supply/24 V segment supply communications power have the same potential. From the power terminal onwards, common ground is led through the potential jumper to the devices as the reference ground "Logical GND" (UL-) for the communications power and analog supply and separately as reference ground GND for the supply and segment level. Separate potentials When providing the 24 V supply for generating UL and UANA The 24 V supply for generating UL and UANA is physically and separately from the 24 V main supply/24 V segment supply therefore electrically isolated from the main supply and the segment supply. When providing the 24 V supply for generating UL and UANA None by jumpering the 24 V main supply/24 V segment supply 8499_en_01 PHOENIX CONTACT 5 IB IL 24 PWR IN/R-XC-PAC 6 Tested successfully: Use under extreme ambient conditions The terminal has been tested successfully over 250 temperature change cycles in accordance with IEC 61131-2 in the range from -40°C to +70°C.   The following conditions were observed: – The Inline devices for all connecting cables were connected with a minimum conductor cross section of 0.5 mm² – The Inline station was assembled on a wall-mounted horizontal DIN rail – Fans were used to ensure continuous movement of air in the control cabinet – The Inline station was not exposed to vibration or shock – The Inline station was operated with a maximum of 24.5 V (ensured by using regulated power supply units) 3 h + 30 min t1 Tmax + 2 K (3 + 0,6) K/min Tmin + 3 K 3 h + 30 min t1 1 Figure 1 Temperature change cycle Temperature in the control cabinet/ambient temperature Cycle WARNING: The terminal is not approved for use in potentially explosive areas. The terminal is not approved for use in safety technology. 8499_en_01 PHOENIX CONTACT 6 IB IL 24 PWR IN/R-XC-PAC 7 Internal circuit diagram Local bus UL+ UANA ULUL US UM 5V 7,5 V 7,5 V 24 V +24 V (US) 1 Figure 2 +24 V (UM) Internal wiring of the terminal points Key: LED Electrically isolated area Power supply unit Diode 1 Reference potential GND (24 V supply) Explanation for other used symbols has been provided in the IL SYS INST UM E user manual. 8499_en_01 PHOENIX CONTACT 7 IB IL 24 PWR IN/R-XC-PAC 8 Terminal point assignment Figure 3 1.1 1.1 2.1 2.1 1.2 1.2 2.2 2.2 1.3 1.3 2.3 2.3 1.4 1.4 2.4 2.4 Terminal point assignment Terminal point Connector 1 Connector 2 Connector 3 1.1 / 2.1 1.2 / 2.2 1.3 / 2.3 1.4 / 2.4 Connector 4 1.1 / 2.1 1.2 / 2.2 1.3 / 2.3 1.4 / 2.4 Designation Assignment Not used Not used Voltage supply for generating the communications power and analog voltage Not used 24 V DC For generating UL and UANA GND Ground Ground of the 24 V supply FE Functional earth Functional earth ground of the power terminal and, therefore, ground of the Inline station. The contacts are directly connected to the potential jumper and the FE spring on the bottom of the housing. Voltage supply for the main circuit and segment circuit 24 V supply for segment circuit 24 V DC US 24 V supply for main circuit 24 V DC UM GND Reference potential of The reference potential is routed directly to the potential the I/O supply jumper and simultaneously functions as reference ground for the main and segment supplies. FE Functional earth Functional earth ground of the power terminal and, therefore, ground of the Inline station. The contacts are directly connected to the potential jumper and the FE spring on the bottom of the housing. Functional earth ground is only used to discharge interference. NOTE: Electronics may be damaged when overloaded NOTE: Malfunction Connect the power terminal to the functional earth ground (FE) via one of the FE connections of connector 3 or connector 4. To do so, connect the corresponding contact to a grounding terminal block. Ensure that the maximum permissible current of 8 A flowing through potential jumpers UM and US (total current) is not exceeded. 8499_en_01 PHOENIX CONTACT 8 IB IL 24 PWR IN/R-XC-PAC 24 V segment supply/24 V main supply 9 Local diagnostic indicators The segment supply and main supply must have the same reference potential. Therefore, an electrically isolated voltage area on the I/O side cannot be created. UL US The main supply and the segment supply are protected against polarity reversal and surge voltage. UM NOTE: Module can become damaged The main supply and segment supply do not have short-circuit protection. The user must provide short-circuit protection. Measure the rating of the fuse connected upstream such that the maximum permissible load current is not exceeded. Figure 4 LED UL US UM Local diagnostic indicators Color Green Green Green Meaning 7.5 V communications power 24 V supply for segment circuit 24 V supply for main circuit 24 V segment supply Function identification You can provide the segment voltage at this terminal or one of the supply terminals. There are several ways of providing the segment voltage at the terminal (connector 4): 1. The segment voltage can be supplied separately at terminal points 1.1 (or 2.1) and 1.3 (or 2.3) (GND) of the power connector. 2. Connections 1.1 (or 2.1) and 1.2 (or 2.2) can be jumpered to tap the supply for the segment circuit from the main circuit. 3. A switch can be inserted between terminal points 1.1 (or 2.1) and 1.2 (or 2.2) to create a switched segment circuit (e.g., an emergency stop circuit). Black 10 Connection example 2.1 1.1 2.1 1.1 2.1 1.1 2.1 2.2 1.2 2.2 1.2 2.2 1.2 2.2 1.3 2.3 1.3 2.3 1.3 2.3 1.3 2.3 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 + 24 V DC (UM) - + 24 V DC (US) - + 24 V DC - (UBK) 24 V supply for generating UL and UANA The 24 V supply has protection against polarity reversal and surge voltage. These protective elements are only used to protect the power supply unit. 1.1 1.2 Figure 5 Typical connection of the supply voltage NOTE: Module can become damaged The 24 V supply does not have short-circuit protection. The user must provide short-circuit protection. Measure the rating of the fuse connected upstream such that the maximum permissible load current is not exceeded. 8499_en_01 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com 9
2701298 价格&库存

很抱歉,暂时无法提供与“2701298”相匹配的价格&库存,您可以联系我们找货

免费人工找货