2701389

2701389

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    OUTPUT MODULE 2 ANALOG 24V

  • 数据手册
  • 价格&库存
2701389 数据手册
IB IL AO 2/UI-XC-PAC Inline analog output terminal, version for extreme conditions, 2 outputs for connection of current and voltage signals Data sheet 8500_en_02 1 © PHOENIX CONTACT 2015-11-04 Description The terminal is designed for use within an Inline station. It is used to output analog current or voltage signals. Thanks to special engineering measures and tests, the terminal can be used under extreme ambient conditions. Features – – – – – – – – 2 analog output channels Connection of actuators in 2-wire technology Current ranges: 0 mA ... 20 mA, 4 mA ... 20 mA, ±20 mA Voltage ranges: 0 V ... 10 V, -10 V ... +10 V Diagnostic and status indicators Can be used under extreme ambient conditions Extended temperature range of -40°C ... +70°C (see “Tested successfully: use under extreme ambient conditions”) Painted PCBs This data sheet is only valid in association with the IL SYS INST UM E user manual. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. IB IL AO 2/UI-XC-PAC 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 4 5 Additional technical data.......................................................................................................... 7 5.1 Tolerance specifications ........................................................................................................ 7 5.2 Step response (signal rise time) .............................................................................................. 7 5.3 Tolerances influenced by electromagnetic interference ................................................................. 7 6 Tested successfully: Use under extreme ambient conditions .................................................. 8 7 Internal circuit diagram ............................................................................................................ 9 8 Electrical isolation.................................................................................................................... 9 9 Terminal point assignment..................................................................................................... 10 10 Connection example.............................................................................................................. 10 11 Connection notes .................................................................................................................. 10 12 Installation instructions .......................................................................................................... 10 13 Local status and diagnostic indicators ................................................................................... 10 14 Process data.......................................................................................................................... 11 14.1 OUT process data.............................................................................................................. 11 14.2 IN process data ................................................................................................................. 12 14.3 Read firmware version ........................................................................................................ 12 15 Representation of the output values in the different formats .................................................. 13 15.1 IB IL format ...................................................................................................................... 13 15.2 Format S7 compatible ......................................................................................................... 14 8500_en_02 PHOENIX CONTACT 2 IB IL AO 2/UI-XC-PAC 3 Ordering data Description Type Order No. Pcs./Pkt. Inline analog output terminal, version for extreme conditions, complete with accessories (connector connector and labeling field), 2 outputs, 0 - 20 mA, 4 - 20 mA, ±20 mA, 0 - 10 V, ±10 V, 2-conductor connection technology IB IL AO 2/UI-XC-PAC 2701389 1 Accessories Type Order No. Pcs./Pkt. Shield connection clamp, for shield on busbars, contact resistance < 1 mΩ (Assembly) SK 8 3025163 10 Shield connection clamp, for shield on busbars, contact resistance < 1 mΩ (Assembly) SK 14 3025176 10 Shield connection clamp, for shield on busbars, contact resistance < 1 mΩ (Assembly) SK 20 3025189 10 Shield connection clamp, for shield on busbars, contact resistance < 1 mΩ (Assembly) SK 35 3026463 10 Support bracket for busbars (Assembly) AB-SK 3025341 10 Support bracket, Bracket for busbars, set every 20 cm, Length: 95.5 mm, Width: 6.2 mm, Color: gray (Assembly) AB-SK 65 3026489 10 Support bracket, Bracket for busbars, set every 20 cm, Length: 10 mm, Width: 56 mm, Height: 20 mm, Color: silver (Assembly) AB-SK/E 3026476 10 PEN conductor busbar, 3mm x 10 mm, length: 1000 mm (Assembly) NLS-CU 3/10 SN 1000MM 0402174 10 Connection terminal block, Connection method Screw connection, Cross section:  0.5 mm² - 6 mm², Width: 7 mm, Color: silver AK 4 0404017 50 Connection terminal block, Connection method Screw connection, Cross section:  0.5 mm² - 6 mm², Width: 7 mm, Color: green-yellow AKG 4 GNYE 0421029 50 Connection terminal block, Connection method Screw connection, Cross section:  0.5 mm² - 6 mm², Width: 7 mm, Color: black AKG 4 BK 0421032 50 Documentation Type Order No. Pcs./Pkt. User manual, English, Automation terminals of the Inline product range IL SYS INST UM E - - Data sheet, English, INTERBUS addressing DB GB IBS SYS ADDRESS - - 8500_en_02 PHOENIX CONTACT 3 IB IL AO 2/UI-XC-PAC 4 Technical data Dimensions (nominal sizes in mm) 140,5 71,5 119,8 Width 12.2 mm Height 119.8 mm Depth 71.5 mm Note on dimensions Housing dimensions General data Weight 66 g (with connector) Ambient temperature (operation) -25 °C ... 55 °C (Standard) -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Connection data Designation Inline connector Connection method Spring-cage connection Conductor cross section solid / stranded 0.08 mm² ... 1.5 mm² / 0.08 mm² ... 1.5 mm² Conductor cross section [AWG] 28 ... 16 Stripping length 8 mm Connection data for UL approvals Designation Inline connector Connection method Spring-cage connection Conductor cross section solid / stranded 0.2 mm² ... 1.5 mm² / 0.2 mm² ... 1.5 mm² Conductor cross section [AWG] 24 ... 16 Stripping length 8 mm 8500_en_02 PHOENIX CONTACT 4 IB IL AO 2/UI-XC-PAC Interface Inline local bus Number 2 Connection method Inline data jumper Transmission speed 500 kBit/s Transmission physics Copper Inline potentials / Power consumption Communications power UL 7.5 V DC (via voltage jumper) Current consumption from UL typ. 55 mA max. 65 mA I/O supply voltage UANA 24 V DC Current consumption from UANA typ. 24 mA (No-load) max. 30 mA (No-load) typ. 38 mA (Nominal voltage load (UOUT1/2 = 10 V, RL = 1 kΩ)) max. 45 mA (Nominal voltage load (UOUT1/2 = 10 V, RL = 1 kΩ)) typ. 65 mA (Nominal current load (IOUT1/2 = 20 mA, RL = 0 Ω)) max. 75 mA (Nominal current load (IOUT1/2 = 20 mA, RL = 0 Ω)) Power consumption typ. 1.32 W (Nominal voltage load (UOUT1/2 = 10 V, RL = 1 kΩ)) typ. 1.97 W (Nominal current load (IOUT1/2 = 20 mA, RL = 0 Ω)) Analog outputs Number of outputs 2 Connection method 2-wire (shielded, twisted pair) D/A resolution 12 bit D/A conversion time typ. 10 µs Representation of output values 12 bits (11 bits + sign bit) Data formats IB IL, S7-compatible Process data update bus-synchronous Permissible cable length max. 250 m (The specifications refer to nominal operation after complying with installation instructions.The specifications refer to the following reference cable type:Shielded power station cable: LiYCY; 2 x 2 x 0,5 mm²; VDE0812) Short-circuit and overload protection Electronic Transient protection Suppressor diode Analog outputs, Current Current output signal 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA Load/output load current output ≤ 450 Ω Precision typ. 0.1 % (of output range final value) Analog outputs, Voltage Voltage output signal 0 V ... 10 V, -10 V ... 10 V Load/output load voltage output > 1 kΩ Precision typ. 0.1 % (of output range final value) Programming Data ID code (hex) 5B ID code (dec.) 91 Length code (hex) 04 Length code (dec.) 04 Process data channel 64 Bit Input address area 8 Byte Output address area 8 Byte Parameter channel (PCP) 0 Byte Register length (bus) 64 Bit 8500_en_02 PHOENIX CONTACT 5 IB IL AO 2/UI-XC-PAC Configuration and parameter data in a PROFIBUS system Required parameter data 10 Byte Need for configuration data 5 Byte Error messages to the higher level control or computer system Failure of the internal I/O supply I/O error message sent to the bus coupler I/O supply failure Message in the diagnostic code (in the IB IL format) Short circuit/overload of the outputs Message in the diagnostic code (in the IB IL format) Configuration invalid Message in the diagnostic code (in the IB IL format) Electrical isolation/isolation of the voltage areas Test section Test voltage 7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC, 50 Hz, 1 min 7.5 V supply (bus logics) / functional earth ground 500 V AC, 50 Hz, 1 min 24 V analog supply (analog I/O) / functional earth ground 500 V AC, 50 Hz, 1 min To achieve electrical isolation between the logic level and the I/O area, supply these areas from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted (see also user manual). Conformance with EMC Directive 2004/108/EC Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B; 6 kV contact discharge, 8 kV air discharge Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A; Field intensity: 10 V/m Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV Transient surge voltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B; DC: ±0.5  kV/±1 kV(symmetrical/unsymmetrical) supply cables; shielded I/O cables: ±1 kV Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class A Approvals For the latest approvals, please visit phoenixcontact.net/products. 8500_en_02 PHOENIX CONTACT 6 IB IL AO 2/UI-XC-PAC 5 Additional technical data 5.1 Tolerance specifications 5.2 Step response (signal rise time) Voltage step 0 V ... 10 V (typical values) Tolerances at TA = +25°C Output range Absolute Typ. Relative Max. Typ. Max. 0 V ...10 V, ±10 V ±10 mV ±20 mV ±0.1 % ±0.2% 0 mA ... 20 mA, 4 mA ... 20 mA, ±20 mA ±20 μA ±60 µA ±0.1 % ±0.3% Load Time for 10 % ... 90 % Time for 0 % ... 99 % RL = 2 kΩ 9 μs 15 μs RL = 2 kΩ II CL = 10 nF 9 μs 15 μs RL = 2 kΩ II CL = 220 nF 135 μs 180 μs RL = 2 kΩ + LL = 3 mH 8 μs 15 μs The typical specifications contain the typical offset, gain and linearity errors. All tolerances indicated as a percentage are related to the positive output range final value. Current step 0 mA ... 20 mA (typical values) The data is valid for nominal operation (UANA = 24 V) in the default configuration. Load Default configuration: IB IL format RL = 500 Ω 3 μs 5 μs RL = 500 Ω II CL = 10 nF 18 μs 30 μs Please also observe the values for the temperature drift. The maximum tolerance values represent the worst case measurement inaccuracy. Besides maximum offset and gain drift, they also comprise longtime drift as well as the maximum tolerances of the test and calibration equipment. Time for 10 % ... 90 % Time for 0 % ... 99 % RL = 500 Ω II CL = 220 nF 300 μs 590 μs RL = 500 Ω + LL = 3 mH 1.6 μs 3 μs RL = 50 Ω II CL = 100 μF 11 μs 27 μs Current step 4 mA ... 20 mA (typical specifications) Tolerance and temperature response at TA = -25°C ... +55°C Output range Load Drift Time for 10 % ... 90 % Time for 0 % ... 99 % Typ. Max. RL = 500 Ω 2.3 μs 4 μs 0 V ...10 V, ±10 V ±30 ppm/K ±50 ppm/K RL = 500 Ω II CL = 10 nF 15 μs 26 μs 0 mA ... 20 mA, 4 mA ... 20 mA, ±20 mA ±30 ppm/K ±50 ppm/K RL = 500 Ω II CL = 220 nF 260 μs 450 μs RL = 500 Ω + LL = 3 mH 1.5 μs 2.8 μs The drift values refer to the relevant output range final value. The values refer to nominal operation with default settings. 5.3 Tolerances influenced by electromagnetic interference Type of electromagnetic interference Typical deviation in % referencing the output range final value Voltage output Current output Electromagnetic fields; field strength 10 V/m according to EN 61000-4-3/ IEC 61000-4-3
2701389 价格&库存

很抱歉,暂时无法提供与“2701389”相匹配的价格&库存,您可以联系我们找货

免费人工找货