0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2701539

2701539

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    AXL E ETH DIO16 M12 6M

  • 数据手册
  • 价格&库存
2701539 数据手册
https://www.phoenixcontact.com/us/products/2701539 Distributed I/O device - AXL E ETH DIO16 M12 6M - 2701539 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Axioline E, Digital input/output, Ethernet, M12 fast connection technology, Digital inputs: 16, 24 V DC, 4-wire, Digital outputs: 16, 24 V DC, 500 mA, 3-conductor, Metal housing, Degree of protection IP65/67 Product Features ■ ■ ■ ■ ■ ■ Connection to Ethernet network using M12connectors (D-coded) Transmission speed of 10 Mbps and 100 Mbps Connection of digital sensors and actuators using M12connectors (A-coded) Diagnostic and status indicators Short-circuit and overload protection of the sensor supply IP65/IP67 degree of protection Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 700.0 g Custom tariff number 85176200 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 60 mm Height 185 mm Depth 38 mm Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate). 04/27/2016   Page 1 / 6 https://www.phoenixcontact.com/us/products/2701539 Distributed I/O device - AXL E ETH DIO16 M12 6M - 2701539 Technical data Dimensions Drill hole spacing 198.5 mm Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -25 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % Permissible humidity (storage/transport) 5 % ... 95 % Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP65/IP67 General Housing material Zinc die-cast Mounting type Wall mounting or DIN rail mounting; both with mounting plate. Net weight 713.8 g Interfaces Fieldbus system Ethernet Designation Ethernet Connection method M12 fast connection technology Note on connection method D-coded Designation connection point Copper cable Transmission speed 10/100 MBit/s (with auto negotiation) Number of positions 4 System limits of the bus coupler Designation Modbus/TCP Equipment type Modbus slave (server) System-specific protocols Modbus protocols Modbus/TCP Protocols supported SNMP v1 HTTP TFTP FTP BootP DHCP Specification Modbus application protocol V1.1b Power supply for module electronics Designation Actuators (UA) for additional devices Connection method M12 connector (T-coded) 04/27/2016   Page 2 / 6 https://www.phoenixcontact.com/us/products/2701539 Distributed I/O device - AXL E ETH DIO16 M12 6M - 2701539 Technical data Power supply for module electronics Number of positions 4 Supply voltage 24 V DC Nominal supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple) Current consumption max. 12 A Typical current consumption 3 mA ±15 % (at 24 V DC) Digital inputs Input name Digital inputs Description of the input EN 61131-2 types 1 and 3 Connection method M12 connector, double occupancy 4-wire Number of inputs 16 Protective circuit Overload protection, short-circuit protection of sensor supply Input filter time < 1000 µs Input voltage range "0" signal -30 V DC ... 5 V DC Input voltage range "1" signal 11 V DC ... 30 V DC Nominal input current at UIN typ. 3 mA Digital outputs Output name Digital outputs Connection method M12 connector, double occupancy 3-conductor Number of outputs 16 Protective circuit Overload protection, short-circuit protection of outputs Electronic Output voltage 24 V DC Nominal output voltage 24 V DC (from voltage US) Maximum output current per channel 500 mA Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage) Nominal load, ohmic 12 W (48 Ω; with nominal voltage) Standards and Regulations Conformity with EMC directives Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical) 04/27/2016   Page 3 / 6 https://www.phoenixcontact.com/us/products/2701539 Distributed I/O device - AXL E ETH DIO16 M12 6M - 2701539 Technical data Standards and Regulations Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V Noise emission test as per EN 61000-6-4 Radio interference properties EN 55022 Class A Test section 24 V supply (communications power/sensor supply, digital inputs/outputs)/ bus connection (Ethernet 1) 500 V AC 50 Hz 1 min. 24 V supply (communications power/sensor supply, digital inputs/outputs)/ bus connection (Ethernet 2) 500 V AC 50 Hz 1 min. 24 V supply (communications power/sensor supply, digital inputs/outputs)/ FE 500 V AC 50 Hz 1 min. Bus connection (Ethernet 1)/FE 500 V AC 50 Hz 1 min. Bus connection (Ethernet 2)/FE 500 V AC 50 Hz 1 min. Bus connection (Ethernet 1)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min. 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, digital inputs/outputs) 500 V AC 50 Hz 1 min. 24 V supply (actuator supply)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min. 24 V supply (actuator supply)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min. 24 V supply (actuator supply)/FE 500 V AC 50 Hz 1 min. Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, halfsine shock pulse Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Protection class III, IEC 61140, EN 61140, VDE 0140-1 Classifications eCl@ss eCl@ss 4.0 27240404 eCl@ss 4.1 27240404 eCl@ss 5.0 27242204 eCl@ss 5.1 27242604 eCl@ss 6.0 27242604 eCl@ss 7.0 27242604 eCl@ss 8.0 27242604 eCl@ss 9.0 27242604 ETIM ETIM 2.0 EC001433 04/27/2016   Page 4 / 6 https://www.phoenixcontact.com/us/products/2701539 Distributed I/O device - AXL E ETH DIO16 M12 6M - 2701539 Classifications ETIM ETIM 3.0 EC001599 ETIM 4.0 EC001599 ETIM 5.0 EC001599 UNSPSC UNSPSC 6.01 43172015 UNSPSC 7.0901 43201404 UNSPSC 11 39121311 UNSPSC 12.01 39121311 UNSPSC 13.2 39121311 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals UL Listed / cUL Listed / cULus Listed Approvals submitted Approval details UL Listed  cUL Listed  cULus Listed  04/27/2016   Page 5 / 6 https://www.phoenixcontact.com/us/products/2701539 Distributed I/O device - AXL E ETH DIO16 M12 6M - 2701539 Drawings Connection diagram Dimensional drawing 194,5 IN/OUT 6 +24 V IN/OUT 12 38 IN/OUT 5 185 60 IN/OUT 11 +24 V Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 04/27/2016   Page 6 / 6
2701539 价格&库存

很抱歉,暂时无法提供与“2701539”相匹配的价格&库存,您可以联系我们找货

免费人工找货