2701813

2701813

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    OUTPUTMODULE16SOLIDSTATE24V

  • 数据手册
  • 价格&库存
2701813 数据手册
https://www.phoenixcontact.com/us/products/2701813 I/O module - AXL F DO16 FLK 1H - 2701813 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Axioline F digital output module, 16 outputs, 24 V DC, 500 mA, FLK20 connection for system cabling (including bus base module and connectors) Product Description The module is designed for use within an Axioline F station. It is used to output digital signals. You can connect PLC relays from the INTERFACE product range quickly and conveniently using the FLK connection. This means that you can also use this output module in applications which require relays, e.g., to switch high voltages or currents.   Product Features  16 digital outputs  24 V DC, 500 mA    Minimum update time of < 100 μs  Device rating plate stored  Diagnostic and status indicators   Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 200.0 g Custom tariff number 85389091 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 35 mm Height 126.1 mm 10/29/2015   Page 1 / 6 https://www.phoenixcontact.com/us/products/2701813 I/O module - AXL F DO16 FLK 1H - 2701813 Technical data Dimensions Depth 54 mm Note on dimensions The depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715). Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Connection data Designation Axioline F connector Connection method Push-in connection Note on connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm General Net weight 108 g Note on weight specifications with connector and bus base module Mounting type DIN rail Protection class III, IEC 61140, EN 61140, VDE 0140-1 Test section 5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min 5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min 24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min Conformance with EMC directives Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B; 6 kV contact discharge, 8 kV air discharge Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A; Field intensity: 10 V/m Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV 10/29/2015   Page 2 / 6 https://www.phoenixcontact.com/us/products/2701813 I/O module - AXL F DO16 FLK 1H - 2701813 Technical data General Noise immunity test in accordance with EN 61000-6-2 Transient surge voltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical) Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, halfsine shock pulse Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Diagnostics messages Short-circuit / overload of the digital outputs Yes Interfaces Designation Axioline F local bus Connection method Bus base module Transmission speed 100 MBit/s Axioline potentials Communications power UBus 5 V DC (via bus base module) Current consumption from UBus max. 120 mA Supply of digital output modules UO 24 V DC Current consumption from UO 8 A (external fuse) Digital outputs Output name Digital outputs Connection method FLK20 pin strip FLK connector (20-pos.) Number of outputs 16 Protective circuit Short-circuit protection, overload protection of the outputs Electronic Output voltage 24 V Nominal output voltage 24 V DC Maximum output current per channel 500 mA Maximum output current per module 8 A (external fuse) Nominal load, inductive max. 12 VA (1.2 H; 48 Ω; with nominal voltage) Nominal load, lamp max. 12 W (at nominal voltage) Nominal load, ohmic max. 12 W (48 Ω; with nominal voltage) 10/29/2015   Page 3 / 6 https://www.phoenixcontact.com/us/products/2701813 I/O module - AXL F DO16 FLK 1H - 2701813 Classifications eCl@ss eCl@ss 4.0 27240404 eCl@ss 4.1 27240404 eCl@ss 5.0 27242204 eCl@ss 5.1 27242604 eCl@ss 6.0 27242604 eCl@ss 7.0 27242604 eCl@ss 8.0 27242604 ETIM ETIM 4.0 EC001599 ETIM 5.0 EC001599 UNSPSC UNSPSC 6.01 43172015 UNSPSC 7.0901 43201404 UNSPSC 11 39121311 UNSPSC 12.01 39121311 UNSPSC 13.2 39121311 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approvals submitted Approval details UL Listed  10/29/2015   Page 4 / 6 https://www.phoenixcontact.com/us/products/2701813 I/O module - AXL F DO16 FLK 1H - 2701813 Approvals cUL Listed  cULus Listed  Drawings Connection diagram Connection diagram 2 1 3 FLK 20/... A1+ A1+ A1+ A1+ A1+ A1+ A1+ A1+ A1+ A1+ A1+ A1+ A1+ A1+ A1+ A1+ A2- A2- A2- A2- A2- A2- A2- A2- A2- A2- A2- A2- A2- A2- A2- A2- 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 4 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Connection of relay modules Connection diagram Dimensional drawing 35 1 54 2 122,4 2 4 6 8 10 12 14 16 18 125,9 3 20 Connection of an interface module 10/29/2015   Page 5 / 6 https://www.phoenixcontact.com/us/products/2701813 I/O module - AXL F DO16 FLK 1H - 2701813 Diagram Energy consumption [J] Block diagram UBus !C Local bus 1 2 15 0,4 Only with external free running circuit 0,35 0,3 0,25 0,2 0,15 0,1 0,05 1 = 0,5 A 2 = 0,4 A 3 = 0,3 A 4 = 0,2 A 5 = 0,1 A 1 2 3 4 5 16 0 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,4 Output circuit D UO 16x E1 1 2 3 UO 24 V Internal wiring of the terminal points Inductance [H] 15 16 DO 1...16 Maximum energy consumption of the outputs when switching off inductive loads The diagram shows the maximum amount of energy that may be fed back into the corresponding output groups (outputs 1 to 4, 5 to 8, 9 to 12, 13 to 16) for each switch off procedure when switching off an inductive load without external freewheeling circuit. The current data refers to the ohmic DC voltage component of the inductive load. Note: Restrict freewheeling voltage to a maximum of -15 V when using an external freewheeling circuit. The external freewheeling circuit has no function in the event of a higher negative voltage. Phoenix Contact 2015 © - all rights reserved http://www.phoenixcontact.com 10/29/2015   Page 6 / 6
2701813 价格&库存

很抱歉,暂时无法提供与“2701813”相匹配的价格&库存,您可以联系我们找货

免费人工找货