0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2702068

2702068

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    AXIOLINE F DIGITAL OUTPUT MODULE

  • 数据手册
  • 价格&库存
2702068 数据手册
https://www.phoenixcontact.com/us/products/2702068 I/O module - AXL F DO4/3 AC 1F - 2702068 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Axioline F, Digital output module, Digital outputs: 4 (Triac outputs with zero voltage switch), 230 V AC, 2 A AC, Connection technology: 3-conductor, Transmission speed in the local bus 100 Mbps, Degree of protection IP20, including bus base module and Axioline F connectors Why buy this product  4 digital outputs  Connection of actuators in 2 and 3-wire technology  Device rating plate stored  Diagnostic and status indicators Key Commercial Data Packing unit 1 STK GTIN GTIN 4046356933087 Weight per Piece (excluding packing) 240.000 g Custom tariff number 85389091 Country of origin Germany Technical data Dimensions Width 53.6 mm Height 126.1 mm Depth 54 mm Note on dimensions The depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715). Ambient conditions 04/13/2017   Page 1 / 6 https://www.phoenixcontact.com/us/products/2702068 I/O module - AXL F DO4/3 AC 1F - 2702068 Technical data Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C (Max. 2 A/channel for wall mounting on horizontal DIN rail; max. 1 A/channel for any mounting position) -25 °C ... 50 °C (Max. 2 A/channel for any mounting position) Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Connection data Designation Axioline F connector Connection method Push-in connection Note on connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. When selecting the cables, please note that in the case of a small conductor cross section and high current, the terminal point temperature may be up to 30 K above the ambient temperature. Conductor cross section solid min. 0.5 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.5 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 20 Conductor cross section AWG max. 16 Stripping length 8 mm General Mounting type DIN rail Net weight 239 g Note on weight specifications with connectors and bus base module Interfaces Designation Axioline F local bus Connection method Bus base module Transmission speed 100 Mbps Power supply for module electronics Connection method Push-in connection Note on connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. When selecting the cables, please note that in the case of a small conductor cross section and high current, the terminal point temperature may be up to 30 K above the ambient temperature. 04/13/2017   Page 2 / 6 https://www.phoenixcontact.com/us/products/2702068 I/O module - AXL F DO4/3 AC 1F - 2702068 Technical data Axioline potentials Communications power UBus 5 V DC (via bus base module) Current consumption from UBus max. 120 mA Supply of digital output modules UO 230 V AC Current consumption from UO max. 8 A (external fuse) Digital outputs Output name Digital outputs Connection method Push-in connection Connection technology 3-conductor Number of outputs 4 (Triac outputs with zero voltage switch) Protective circuit External protection required I t-value (a half-wave): 340 A s Output voltage 230 V AC Nominal output voltage 230 V AC Maximum output current per channel 2 A AC Maximum output current per module 8 A AC (external fuse) Nominal load, ohmic max. 460 W (at nominal voltage) 2 2 Electrical isolation Test section I/Os / logic 4 kV Rated surge voltage (safe isolation according to EN 61010-2-201/IEC 61010-2-201) I/Os / logic 5 kV Pulse test voltage according to EN 61850/IEC 61850 I/O / functional earth ground 4 kV Rated surge voltage (safe isolation according to EN 61010-2-201/IEC 61010-2-201) I/O / functional earth ground 5 kV Pulse test voltage according to EN 61850/IEC 61850 I/O area AC / PE 4 kV Rated surge voltage (basic insulation according to EN 61010-2-201/IEC 61010-2-201) Standards and Regulations Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Developed according to standard IEC 61850-3 Immunity to magnetic fields, EN 61000-4-8/IEC 61000-4-8 300 A/m continuous, 1000 A/m for 1 s IEC 61850-3 Immunity to attenuated oscillating magnetic fields, EN 61000-4-10/IEC 61000-4-10 100 A/m IEC 61850-3 Immunity to conducted common-mode interference, EN 61000-4-16/IEC 61000-4-16 30 V continuous, 300 V for 1 s IEC 61850-3 Attenuated oscillating waves, EN 61000-4-18/IEC 61000-4-18 1 kV symmetrical, 2.5 kV asymmetrical Environmental Product Compliance 04/13/2017   Page 3 / 6 https://www.phoenixcontact.com/us/products/2702068 I/O module - AXL F DO4/3 AC 1F - 2702068 Technical data Environmental Product Compliance China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values Drawings Connection diagram a1 00 01 02 03 b1 10 11 12 13 b2 20 21 22 23 c1 30 31 32 33 Dimensional drawing 53,6 54 L 230 V AC 126,1 122,4 N 5 OUT4 N Connection with 3-wire technology Block diagram UBus C 00 03 Local bus D UO E1 02 03 OUT 1...4 UO 24 V AC ...230 V AC Internal wiring of the terminal points Classifications eCl@ss eCl@ss 5.1 27242604 eCl@ss 6.0 27242604 eCl@ss 8.0 27242604 eCl@ss 9.0 27242604 04/13/2017   Page 4 / 6 https://www.phoenixcontact.com/us/products/2702068 I/O module - AXL F DO4/3 AC 1F - 2702068 Classifications ETIM ETIM 5.0 EC001599 ETIM 6.0 EC001599 UNSPSC UNSPSC 13.2 32151602 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approval details UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cULus Listed       Accessories Accessories Device marking 04/13/2017   Page 5 / 6 https://www.phoenixcontact.com/us/products/2702068 I/O module - AXL F DO4/3 AC 1F - 2702068 Accessories Insert label - EMT (35X46)R - 0801604 Insert label, for the Axioline F series from Phoenix Contact, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLL, THERMOMARK ROLL X1, THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, THERMOMARK S1.1, Mounting type: snapped into marker carrier, Lettering field: 35 x 46 mm     DIN rail connector Bus connector - AXL F BS F - 2688129 Axioline F bus base module for housing type F     Terminal marking Zack marker strip - ZB 20,3 AXL UNPRINTED - 0829579 Zack marker strip for Axioline F (device labeling), in 2 x 20.3 mm pitch, unprinted, 25-section, for individual labeling with B-STIFT 0.8, X-PEN, or CMS-P1-PLOTTER     Zack Marker strip, flat - ZBF 7,5:UNBEDRUCKT - 0809942 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, Mounting type: Snap into flat marker groove, for terminal block width: 7.5 mm, Lettering field: 5.15 x 7.4 mm     Phoenix Contact 2017 © - all rights reserved http://www.phoenixcontact.com 04/13/2017   Page 6 / 6
2702068 价格&库存

很抱歉,暂时无法提供与“2702068”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2702068
    •  国内价格 香港价格
    • 1+2580.678841+321.21114

    库存:0