2702133

2702133

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    OUTPUT MODULE 2 SOLID STATE 24V

  • 数据手册
  • 价格&库存
2702133 数据手册
IB IL 24 DO 2-2A-XC-PAC Inline digital output terminal, version for extreme conditions, 2 outputs, 24 V DC, 2 A Data sheet 106145_en_00 1 © PHOENIX CONTACT 2014-07-29 Description The terminal is designed for use within an Inline station. It is used to output digital signals. Thanks to special engineering measures and tests, the terminal can be used under extreme ambient conditions. Features – – – – – – – – – Connections for two digital actuators Connection of actuators in 2, 3, and 4-wire technology Nominal current of each output: 2 A Total current of the terminal: 4 A Short-circuit and overload protected outputs Diagnostic and status indicators Can be used under extreme ambient conditions Painted PCBs Extended temperature range T2 (-40°C ... +55°C)   This data sheet is only valid in association with the IL SYS INST UM E user manual. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. IB IL 24 DO 2-2A-XC-PAC 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 3 5 Additional tables ...................................................................................................................... 6 5.1 Output characteristic curve..................................................................................................... 6 5.2 Power dissipation ................................................................................................................ 6 5.3 Limitation of simultaneity, derating ........................................................................................... 6 6 Tested successfully: Use under extreme ambient conditions .................................................. 7 7 Internal circuit diagram ............................................................................................................ 7 8 Local status and diagnostic indicators ..................................................................................... 8 9 Terminal point assignment....................................................................................................... 8 10 Connection notes and examples ............................................................................................. 8 11 Process data............................................................................................................................ 8 106145_en_00 PHOENIX CONTACT 2 IB IL 24 DO 2-2A-XC-PAC 3 Ordering data Description Order No. Pcs. / Pkt. Inline digital output terminal, version for extreme conditions, complete with IB IL 24 DO 2-2A-XC-PAC accessories (connector plug and marking field), 2 outputs, 24 V DC, 2 A, 4conductor connection technology Type 2702133 1 Accessories Type Order No. Pcs. / Pkt. Labeling field, width: 12.2 mm (Marking) IB IL FIELD 2 2727501 10 Insert strip, Sheet, white, unlabeled, can be labeled with: Office printing systems, Plotter: Laser printer, Mounting type: Insert, Lettering field: 62 x 10 mm (Marking) ESL 62X10 0809492 1 Insert strip, Sheet, white, unlabeled, can be labeled with: Office printing systems, Plotter: Laser printer, Mounting type: Insert, Lettering field: 62 x 46 mm (Marking) ESL 62X46 0809502 5 Inline connector, colored (Connector/Adapter) IB IL SCN-8-CP 2727608 10 Connector, for digital 1, 2 or 8-channel Inline terminals (Connector/ Adapter) IB IL SCN-8 2726337 10 Documentation Type Order No. Pcs. / Pkt. User manual, English, Automation terminals of the Inline product range IL SYS INST UM E - - Data sheet, English, INTERBUS addressing DB GB IBS SYS ADDRESS - - 4 Technical data Dimensions (nominal sizes in mm) 140,5 71,5 119,8 Width 12.2 mm Height 119.8 mm Depth 71.5 mm Note on dimensions Housing dimensions General data Color green Weight 61 g   (with connector) Operating mode Process data mode with 2 bits Ambient temperature (operation) -40 °C ... 55 °C (See also the "Tested successfully: Use under extreme ambient conditions" section of the data sheet.) Ambient temperature (operation) -40 °C ... 60 °C (At US < 24.5 V; see also the "Tested successfully: Use under extreme ambient conditions" section of the data sheet.) 106145_en_00 PHOENIX CONTACT 3 IB IL 24 DO 2-2A-XC-PAC General data Ambient temperature (storage/transport) -40 °C ... 85 °C Temperature class T2 (-40°C ... 55°C, EN 50155) Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Connection data Designation Inline connector Connection method Spring-cage connection Conductor cross section solid / stranded 0.08 mm²   ...   1.5 mm²   /   0.08 mm²   ...   1.5 mm² Conductor cross section [AWG] 28   ...   16 Stripping length 8 mm Connection data for UL approvals Designation Inline connector Connection method Spring-cage connection Conductor cross section solid / stranded 0.2 mm²   ...   1.5 mm²   /   0.2 mm²   ...   1.5 mm² Conductor cross section [AWG] 24   ...   16 Stripping length 8 mm Interface Inline local bus Connection method Inline data jumper Transmission speed 500 kBit/s Power consumption Segment supply voltage US 24 V DC (nominal value) Current consumption from US max. 4 A Communications power UL 7.5 V DC (via voltage jumper) Current consumption from UL max. 35 mA Power consumption max. 0.27 W (at UL) Digital outputs Number of outputs 2 Connection method Spring-cage connection Connection method 2, 3, 4-wire Nominal output voltage 24 V DC Voltage difference with nominal current ≤1V Maximum output current per channel 2A Maximum output current per device 4A Nominal load, ohmic 48 W (12 Ω) Nominal load, inductive 48 VA (1.2 H, 12 Ω) Nominal load, lamp 48 W Signal delay when switching on an ohmic nominal load approx. 200 µs Signal delay when switching on an inductive nominal load approx. 250 ms (1.2 H, 12 Ω) Signal delay when switching on a lamp nominal load typ. 200 ms (for switching frequencies up to 8 Hz; above this frequency, the lamp load behaves like an ohmic load) Signal delay when switching off an ohmic nominal load approx. 200 µs Signal delay when switching off an inductive nominal load approx. 250 ms (1.2 H, 12 Ω) 106145_en_00 PHOENIX CONTACT 4 IB IL 24 DO 2-2A-XC-PAC Digital outputs Signal delay when switching off a lamp nominal load approx. 200 µs Maximum operating frequency with ohmic nominal load max. 300 Hz (this switching frequency is limited by the data rate selected, the number of bus devices, the structure of the bus, the software used and the control or computer system used) Maximum operating frequency with inductive nominal load max. 0.5 Hz (1.2 H, 12 Ω) Maximum operating frequency with lamp nominal load max. 300 Hz (this switching frequency is limited by the data rate selected, the number of bus devices, the structure of the bus, the software used and the control or computer system used) Behavior at voltage switch-off The output follows the power supply without delay Limitation of the voltage induced on circuit interruption approx. -0.7 V Behavior with overload Auto restart Behavior with inductive overload Output can be destroyed Reverse voltage resistance to short pulses Reverse voltage proof Resistance to permanent reverse voltage to 2 A DC Overload protection, short-circuit protection of outputs Yes Type of external protective circuit Freewheeling diode per channel Programming Data ID code (hex) BD ID code (dec.) 189 Length code (hex) C2 Length code (dec.) 194 Process data channel 2 Bit Input address area 0 Bit Output address area 2 Bit Parameter channel (PCP) 0 Bit Register length (bus) 2 Bit For the programming data/configuration data of other bus systems, please refer to the corresponding electronic device data sheet (e.g., GSD, EDS). Fieldbus data telegram Fieldbus system PROFIBUS DP Required parameter data 3 Byte Need for configuration data 4 Byte Error messages to the higher level control or computer system Short-circuit / overload of the digital outputs Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module Electrical isolation/isolation of the voltage areas Test section Test voltage 5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V AC, 50 Hz, 1 min 5 V supply, outgoing remote bus/7.5 V supply (bus logics) 500 V AC, 50 Hz, 1 min 7.5 V supply (bus logics)/24 V supply (I/O) 500 V AC, 50 Hz, 1 min 24 V supply (I/O) / functional earth ground 500 V AC, 50 Hz, 1 min To achieve electrical isolation between the logic level and the I/O area, supply these areas from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted (see also user manual). Approvals For the latest approvals, please visit phoenixcontact.net/products. 106145_en_00 PHOENIX CONTACT 5 IB IL 24 DO 2-2A-XC-PAC 5 Additional tables 5.1 Output characteristic curve Output characteristic curve when switched on (typical) Output current (A) Differential output voltage (V) 0 0 0.2 0.02 0.4 0.04 0.6 0.06 0.8 0.08 1.0 0.10 1.2 0.12 1.4 0.14 1.6 0,16 1.8 0.18 2.0 0,20 2.2 0.22 5.2 Power dissipation Formula for calculating the power dissipation of the electronics n PEL = 0,18 W + ∑ (0,20 W + ILi2 x 0,10 Ω) i=1 Where: PEL i n ILi Total power dissipation in the terminal Continuous index Number of set outputs (n = 1 ... 2) Load current of output i Power dissipation of the housing PHOU = 2.4 W -25°C < TA ≤ -5°C PHOU = 2.4 W - {[TA - (-5 °C)]/37.5 K/W}   -5°C < TA ≤ +55°C Where: PHOU Power dissipation of the housing Ambient temperature TA 5.3 106145_en_00 Limitation of simultaneity, derating Ambient temperature Tamb Maximum load current   100 % simultaneity ≤ 55 °C 1 A 2A ≤ 40°C 2A 2A 50 % simultaneity PHOENIX CONTACT 6 IB IL 24 DO 2-2A-XC-PAC 6 Tested successfully: Use under extreme ambient conditions 7 Internal circuit diagram The terminal has been tested successfully over 250 temperature change cycles in accordance with IEC 61131-2 in the range from -40°C to +70°C.   Local bus UL The following conditions were observed: – The Inline devices for all connecting cables were connected with a minimum conductor cross section of 0.5 mm² – The Inline station was assembled on a wall-mounted horizontal DIN rail – Fans were used to ensure continuous movement of air in the control cabinet – The Inline station was not exposed to vibration or shock – The Inline station was operated with a maximum of 24.5 V (ensured by using regulated power supply units) +24 V (US) +24 V (UM) 3 h + 30 min t1 Tmax + 2 K (3 + 0,6) K/min Tmin + 3 K 3 h + 30 min Figure 2 Internal wiring of the terminal points Key: t1 1 Figure 1 OPC OPC Protocol chip (Bus logic including voltage conditioning) Temperature change cycle LED (status indicator) Temperature in the control cabinet/ambient temperature Optocoupler Cycle Transistor Digital output WARNING: The terminal is not approved for use in potentially explosive areas. Electrically isolated area The terminal is not approved for use in safety technology. Explanation for other used symbols has been provided in the IL SYS INST UM E user manual. 106145_en_00 PHOENIX CONTACT 7 IB IL 24 DO 2-2A-XC-PAC Local status and diagnostic indicators D 2 Local status and diagnostic indicators Designa- Color tion D Green 1 ... 2 When connecting the actuators, observe the assignment of the terminal points to the process data. Yellow Meaning Diagnostics (bus and logic voltage) Status of the outputs Figure 5 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 +24 V Figure 3 Connection notes and examples OUT 2 1 10 OUT 1 8 Typical connection of actuators Function identification The connection of actuators in 4 and 3-wire technology is illustrated. Pink 9 Terminal point assignment 11 Process data Assignment of the terminal points to the output process data Figure 4 1.1 1.1 2.1 2.1 1.2 1.2 2.2 2.2 1.3 1.3 2.3 2.3 1.4 1.4 2.4 2.4 (Byte.Bit) view Byte.Bit Assignment Terminal point (signal) Terminal point (24 V) Terminal point (GND) Terminal point (FE) Status indicator LED 0.0 1.1 2.2 1.2 2.3 1.3 2.4 1.4 2 1 Terminal point assignment Terminal point Assignment 1.1 / 2.1 Signal output (OUT 1 / OUT 2) 1.2, 2.2 Segment voltage US for 4-wire connection Measuring points for segment voltage US (24 V DC) 1.3, 2.3 Ground connection (GND) for 2, 3 and 4wire connection 1.4, 2.4 FE connection for 3 and 4-wire connection 106145_en_00 0.1 2.1 For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet. PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com 8
2702133 价格&库存

很抱歉,暂时无法提供与“2702133”相匹配的价格&库存,您可以联系我们找货

免费人工找货