0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2702263

2702263

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    输入模块 DIN 轨道 24VDC

  • 数据手册
  • 价格&库存
2702263 数据手册
https://www.phoenixcontact.com/in/products/2702263 Safety module - AXL F SSDI8/4 1F - 2702263 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Safety-related digital input module, IP20 protection, for the SafetyBridge system. The module has 4 safe digital inputs for two-channel assignment or 8 safe digital inputs for single-channel assignment. Product Description The safety module is an input module from the Axioline F product range for use in a SafetyBridge technology V3 system. The safety module can ® be used as part of an Axioline F station at any point within an EtherCAT , EtherNet/IP™, Sercos, Modbus, PROFINET or PROFIBUS system. The module has four safe digital inputs for two-channel assignment or eight safe digital inputs for single-channel assignment. Depending on the installation and parameterization, in the SafetyBridge technology V3 system the safety module can achieve the following safety integrity: - Up to SIL 3 according to standard EN 61508 - Up to SILCL 3 according to standard EN 62061 - Up to Cat. 4/PL e according to standard EN ISO 13849-1 Why buy this product  Cost-effective system configuration, as no safety PLC or safe fieldbus system is required  Flexible use, thanks to compatibility with all bus couplers from the Axioline F range  Reduced installation time, thanks to fast wiring and easy handling  Easy configuration using the free SAFECONF software  Up to SIL 3 according to EN 61508  Up to SILCL 3 according to EN 62061  Up to cat. 4/PL e according to EN ISO 13849-1 Key Commercial Data Packing unit 1 STK GTIN GTIN 4055626066813 Weight per Piece (excluding packing) 347.600 g Custom tariff number 85389091 Country of origin Germany 05/03/2018   Page 1 / 6 https://www.phoenixcontact.com/in/products/2702263 Safety module - AXL F SSDI8/4 1F - 2702263 Technical data Dimensions Width 53.6 mm Height 126.1 mm Depth 54 mm Note on dimensions Housing dimensions Ambient conditions Ambient temperature (operation) -35 °C ... 60 °C (Mounting position: any) Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 75 % (on average, 85% infrequently, non-condensing) Permissible humidity (storage/transport) 10 % ... 75 % (non-condensing) Air pressure (operation) 70 kPa ... 108 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 66 kPa ... 108 kPa (up to 3500 m above sea level) Degree of protection IP20 Interfaces Designation Axioline F local bus (Note: not suitable for use in the Axioline F local bus of the Phoenix Contact AXC 3050 controller) No. of channels 1 Connection method Bus base module Digital inputs Input name Digital inputs Description of the input IEC 61131-2 type 3 Connection method Push-in connection Connection technology 2, 3, 4-wire Number of inputs 4 (with two-channel assignment) 8 (for single-channel assignment) Input filter time 1.5 ms Input characteristic curve IEC 61131-2 type 3 Input voltage 24 V DC (via clock outputs T1 and T2 or external supply) Input voltage range -3 V DC ... 30.2 V DC Nominal input current at UIN typ. 4.2 mA Typical input current per channel 4.2 mA General Mounting type DIN rail Net weight 347.6 g Note on weight specifications with connectors and bus base module Axioline potentials Designation Axioline F local bus supply (UBus) Supply voltage 5 V DC (via bus base module) 05/03/2018   Page 2 / 6 https://www.phoenixcontact.com/in/products/2702263 Safety module - AXL F SSDI8/4 1F - 2702263 Technical data Axioline potentials typ. 280 mA (all inputs set; power supply by UI of 19.2 V DC to 30.2 V DC) Current consumption max. 310 mA Designation Supply for digital input modules (UI) Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30.2 V DC (including all tolerances, including ripple) Current consumption typ. 9 mA (all inputs set; power supply by UI with 30.2 V DC; without power supply to the sensors via clock supplies T1 and T2) Type of protection Protection against polarity reversal, EMC protective circuit, undervoltage detection Safety-related characteristic data Designation IEC 61508 - High demand Safety Integrity Level (SIL) max. 3 (two channel; dependent in parameterization and wiring) Designation IEC 61508 - Low demand Safety Integrity Level (SIL) max. 3 (two channel; dependent in parameterization and wiring) Designation EN ISO 13849 Performance level (PL) max. e (two channel; dependent in parameterization and wiring) Category max. 4 (two channel; dependent in parameterization and wiring) Designation EN 62061 Safety Integrity Level Claim Limit (SIL CL) max. 3 (two channel; dependent in parameterization and wiring) Standards and Regulations Protection class III, IEC 61140, EN 61140, VDE 0140-1 Environmental Product Compliance China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values Drawings Dimensional drawing 126,1 54 122,4 53,6 05/03/2018   Page 3 / 6 https://www.phoenixcontact.com/in/products/2702263 Safety module - AXL F SSDI8/4 1F - 2702263 Classifications eCl@ss eCl@ss 5.1 27242604 eCl@ss 8.0 27242604 eCl@ss 9.0 27242604 ETIM ETIM 5.0 EC001599 ETIM 6.0 EC001599 UNSPSC UNSPSC 13.2 32151602 Approvals Approvals Approvals UL Listed / cUL Listed / Functional Safety / Functional Safety / cULus Listed Ex Approvals Approval details UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 Functional Safety      968/EZ 424.05/17 Functional Safety      968/EZ 424.05/17 05/03/2018   Page 4 / 6 https://www.phoenixcontact.com/in/products/2702263 Safety module - AXL F SSDI8/4 1F - 2702263 Approvals cULus Listed       Accessories Accessories Device marking Insert label - EMT (35X28)R - 0801602 Insert label, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLL, THERMOMARK ROLL X1, THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, THERMOMARK S1.1, mounting type: snapped into marker carrier, lettering field size: 35 x 28 mm     DIN rail connector Bus connector - AXL F BS F - 2688129 Axioline F bus base module for housing type F     Terminal marking Zack marker strip - ZB 20,3 AXL UNPRINTED - 0829579 Zack marker strip for Axioline F (device labeling), in 2 x 20.3 mm pitch, unprinted, 25-section, for individual labeling with B-STIFT 0.8, X-PEN, or CMS-P1-PLOTTER     Zack Marker strip, flat - ZBF 10/5,8 AXL UNPRINTED - 0829580 Zack marker strip, flat, in 10 mm pitch, unprinted, 10-section, for individual labeling with M-PEN 0,8, X-PEN, or CMSP1-PLOTTER     05/03/2018   Page 5 / 6 https://www.phoenixcontact.com/in/products/2702263 Phoenix Contact 2018 © - all rights reserved http://www.phoenixcontact.com 05/03/2018   Page 6 / 6
2702263 价格&库存

很抱歉,暂时无法提供与“2702263”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2702263
    •  国内价格 香港价格
    • 1+4533.377431+565.07536
    • 10+4170.7121910+519.86995

    库存:42