GW/ ...E/...DB9
Universal device servers and protocol converters
Data sheet
3750_en_A
1
© PHOENIX CONTACT 2017-04-12
Description
2
The Phoenix Contact family of Ethernet protocol converters
and device servers provides a simple way to migrate legacy
serial devices and buses to modern Ethernet networks.
Variants are available with one, two, or four D-SUB 9 serial
ports and one or two RJ45 Ethernet ports.
–
Start-up and configuration are simple using an embedded
web server, and communication is kept secure with 256-bit
AES encryption and optional authentication. With a wide
operating temperature range (-40 to +70°C) and hazardous
area approvals, the devices are suitable for use in any
industry.
–
–
–
–
Features
256-bit AES encryption for secure transfer of sensitive
data
Web-based management (WBM) configuration
Comprehensive diagnostics for fast and easy
troubleshooting
Compact DIN rail-mount form factor
COM port redirector software and Windows® operating
system COM port drivers
The most common industrial protocols are supported, with
various combinations of RAW/ASCII serial data, Modbus®
RTU, TCP/IP, Modbus TCP, and EtherNet/IP™ technology.
Make sure you always use the latest documentation.
It can be downloaded at phoenixcontact.net/products.
This document is valid for all products listed in the “Ordering data” on page 3
GW/ ...E/...DB9
3
Selection guide
A variety of different protocol converters and device servers
are available in four different port combinations.
Serial ports (D-SUB 9)
one
two
two
four
Ethernet ports (RJ45)
one
one
two
two
The serial ports are universal RS-232/422/485.
Device server
The GW/ DEVICE/ SERVER… devices migrate legacy
serial devices to modern Ethernet networks. With the aid of
virtual communication ports, existing application software
that only support serial communication can be redirected to
the network card of a computer with a Windows® operating
system.
The COM Port redirector software, as well as a Windows
driver, is available for integration with a PC application free
of charge.
TCP. These modules are extremely powerful and can be
configured to almost any combination of Modbus client and
server, including a shared memory configuration, allowing
two Modbus masters (servers) to communicate with each
other. Device ID aliasing is also supported to create a
“virtual” Modbus ID for Modbus devices that do not have
configurable Modbus addresses.
ASCII to Modbus TCP
The GW/ MODBUS/ TCP/ASCII… modules are used to
convert RAW or ASCII serial strings from devices such as
barcode scanners, weigh scales, or RFID tags into Modbus
registers. Filtering rules may be created in the modules in
order to mask start and stop delimiters of a bar code, for
example, to simplify integration into a programmable
controller.
ASCII to EtherNet/IP™
The GW/ EIP/ASCII… modules are used to convert RAW or
ASCII serial strings from devices such as barcode scanners,
weigh scales, or RFID tags into EtherNet/IP. Filtering rules
may be created in the modules in order to mask start and
stop delimiters of a bar code, for example, to simplify
integration into a programmable controller.
Modbus RTU to Modbus TCP
The GW/ MODBUS/ TCP/RTU… devices are used to
convert serial-based Modbus RTU (or ASCII) to Modbus
Device A
Modbus TCP
master
Modbus RTU
master
Device B
Modbus ASCII
master
Modbus RTU slave
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ DEVICE/ SERVER…
GW/ MODBUS/ TCP/
RTU…
Modbus ASCII slave
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ DEVICE/ SERVER…
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ DEVICE/ SERVER…
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ DEVICE/ SERVER…
Modbus TCP master
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
–
Modbus TCP slave
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
–
Serial RAW/ASCII
GW/ MODBUS/ TCP/
ASCII…
GW/ MODBUS/ TCP/
ASCII…
GW/ MODBUS/ TCP/
ASCII…
GW/ DEVICE/ SERVER…
GW/ EIP/ASCII…
Ethernet RAW/ASCII
GW/ MODBUS/ TCP/
ASCII…
GW/ MODBUS/ TCP/
ASCII…
GW/ MODBUS/ TCP/
ASCII…
–
GW/ EIP/ASCII…
Modbus RTU master
Modbus ASCII master
3750_en_A
Encapsulated
TCP/IP
EtherNet/IP
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
GW/ MODBUS/ TCP/
RTU…
PHOENIX CONTACT
2/13
GW/ ...E/...DB9
4
Ordering data
Products
Description
Type
Order No.
Pcs./Pkt.
Serial device server for converting serial data (RS-232/422/485) to Ethernet
data (RJ45). Supports TCP and UDP protocols. COM port redirector software
and Windows drivers are available for download. Includes one RJ45 port and
one D-SUB 9 port.
GW DEVICE SERVER 1E/1DB9
2702758
1
Serial device server for converting serial data (RS-232/422/485) to Ethernet
data (RJ45). Supports TCP and UDP protocols. COM port redirector software
and Windows drivers are available for download. Includes one RJ45 port and
two D-SUB 9 ports.
GW DEVICE SERVER 1E/2DB9
2702760
1
Serial device server for converting serial data (RS-232/422/485) to Ethernet
data (RJ45). Supports TCP and UDP protocols. COM port redirector software
and Windows drivers are available for download. Includes two RJ45 port and
two D-SUB 9 ports.
GW DEVICE SERVER 2E/2DB9
2702761
1
Serial device server for converting serial data (RS-232/422/485) to Ethernet
data (RJ45). Supports TCP and UDP protocols. COM port redirector software
and Windows drivers are available for download. Includes two RJ45 ports and
four D-SUB 9 ports.
GW DEVICE SERVER 2E/4DB9
2702763
1
The GW MODBUS TCP/RTU… gateway converts serial based Modbus RTU
(or ASCII) to Modbus TCP. Supports serial master or slave devices. Includes
one RJ45 port and one D-SUB 9 port.
GW MODBUS TCP/RTU 1E/1DB9
2702764
1
The GW MODBUS TCP/RTU… gateway converts serial based Modbus RTU
(or ASCII) to Modbus TCP. Supports serial master or slave devices. Includes
one RJ45 port and two D-SUB 9 ports.
GW MODBUS TCP/RTU 1E/2DB9
2702765
1
The GW MODBUS TCP/RTU… gateway converts serial based Modbus RTU
(or ASCII) to Modbus TCP. Supports serial master or slave devices. Includes
two RJ45 ports and two D-SUB 9 ports.
GW MODBUS TCP/RTU 2E/2DB9
2702766
1
The GW MODBUS TCP/RTU… gateway converts serial based Modbus RTU
(or ASCII) to Modbus TCP. Supports serial master or slave devices. Includes
two RJ45 ports and four D-SUB 9 ports.
GW MODBUS TCP/RTU 2E/4DB9
2702767
1
The GW MODBUS TCP/ASCII… converts RAW or ASCII serial strings into
Modbus registers. Includes one RJ45 port and one D-SUB 9 port.
GW MODBUS TCP/ASCII 1E/1DB9
2702768
1
The GW MODBUS TCP/ASCII… converts RAW or ASCII serial strings into
Modbus registers. Includes one RJ45 port and two D-SUB 9 ports.
GW MODBUS TCP/ASCII 1E/2DB9
2702769
1
The GW MODBUS TCP/ASCII… converts RAW or ASCII serial strings into
Modbus registers. Includes two RJ45 ports and two D-SUB 9 ports.
GW MODBUS TCP/ASCII 2E/2DB9
2702770
1
The GW MODBUS TCP/ASCII… converts RAW or ASCII serial strings into
Modbus registers. Includes two RJ45 ports and four D-SUB 9 ports.
GW MODBUS TCP/ASCII 2E/4DB9
2702771
1
The GW EIP/ASCII… converts RAW or ASCII serial strings into EtherNet/IP™
protocol. Includes one RJ45 port and one D-SUB 9 port.
GW EIP/ASCII 1E/1DB9
2702772
1
The GW EIP/ASCII… converts RAW or ASCII serial strings into EtherNet/IP™
protocol. Includes one RJ45 port and two D-SUB 9 ports.
GW EIP/ASCII 1E/2DB9
2702773
1
The GW EIP/ASCII… converts RAW or ASCII serial strings into EtherNet/IP™
protocol. Includes two RJ45 ports and two D-SUB 9 ports.
GW EIP/ASCII 2E/2DB9
2702774
1
The GW EIP/ASCII… converts RAW or ASCII serial strings into EtherNet/IP™
protocol. Includes two RJ45 ports and four D-SUB 9 ports.
GW EIP/ASCII 2E/4DB9
2702776
1
3750_en_A
PHOENIX CONTACT
3/13
GW/ ...E/...DB9
Accessories
Description
Type
Order No.
RS-232 cable, D-SUB 9 socket on D-SUB 9 socket, 9-wire, 1:1
PSM-KA9SUB9/BB/2METER
2799474
1
Patch cable, CAT5, assembled, 0.5 m
FL CAT5 PATCH 0,5
2832263
1
Pcs./Pkt.
Patch cable, CAT5, assembled, 5 m
FL CAT5 PATCH 5,0
2832580
1
D-SUB 9 female connector, one cable entry
很抱歉,暂时无法提供与“2702763”相匹配的价格&库存,您可以联系我们找货