0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2702902

2702902

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    Safety Relay, Dpst-No, 24Vdc, Din Rail; Coil Voltage:24Vdc; Contact Configuration:dpst-No; Product R...

  • 数据手册
  • 价格&库存
2702902 数据手册
https://www.phoenixcontact.com/au/products/2702902 Safety relays - PSR-MC42-2NO-1DO-24DC-SP - 2702902 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Safety relay with IO-Link for emergency stop, safety doors, and light grids, up to SILCL 3, Cat. 4, PL e, 2 sensor circuits, automatic or manual, monitored start, 2 enabling current paths, 1 signal output, US = 24 V DC, plug-in spring-cage terminal block Your advantages  Up to Cat. 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508  Single and two-channel control  2 sensor circuits  2 enabling current paths, 1 digital signal output  Diagnostic data via IO-Link in combination with PSR-CT safety switches  For emergency stop and safety door monitoring, plus evaluation of light grids  Manually monitored and automatic activation Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626458564 Weight per Piece (excluding packing) 181.800 g Sales Key DNA181 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 17.5 mm Height 116.6 mm Depth 114.5 mm 07/16/2019   Page 1 / 9 https://www.phoenixcontact.com/au/products/2702902 Safety relays - PSR-MC42-2NO-1DO-24DC-SP - 2702902 Technical data Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing) Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing) Maximum altitude ≤ 2000 m (Above sea level) Power supply Designation A1/A2 Rated control circuit supply voltage US 24 V DC -20 % / +25 % (provide external protection) Rated control supply current IS typ. 60 mA Power consumption at US typ. 1.44 W Inrush current typ. 2.5 A (Δt = 500 µs at Us) Filter time 1 ms (at A1 in the event of voltage dips at Us) Protective circuit Serial protection against polarity reversal Suppressor diode Supply of the IO-Link ports Designation L+/L- Nominal voltage for I/O supply 24 V DC -20 % / +25 % (is provided via the IO-Link interface of the IOLink master.) Current consumption typ. 16 mA Type of protection Serial protection against polarity reversal Protective circuit/component Suppressor diode Digital inputs Input name Sensor circuit S0 S12, S22 Description of the input safety-related sensor inputs NPN (S12), NPN/PNP (S22) Number of inputs 2 Input voltage range "0" signal 0 V DC ... 5 V DC (S12) For S22, see note in “Signal generator connection versions” section. Input voltage range "1" signal 11 V DC ... 30 V DC Input current range "0" signal 0 mA ... 2 mA (S12, S22) Inrush current < 5 mA (typ. with US at S12, Δt = 150 ms) < 5 mA (typically with US at S22/24 V, Δt = 500 µs) > -5 mA (typically with US at S22/0 V, Δt = 500 µs) Current consumption < 5 mA (Typically with US at S12) < 5 mA (typically with US at S22/24 V) > -5 mA (typically with US at S22/0 V) Filter time 1.5 ms (Test pulse width of low test pulses) Test pulse rate = 5 x Test pulse width Deactivate switch-on pulses/light tests for safety applications. 07/16/2019   Page 2 / 9 https://www.phoenixcontact.com/au/products/2702902 Safety relays - PSR-MC42-2NO-1DO-24DC-SP - 2702902 Technical data Digital inputs Max. permissible overall conductor resistance 150 Ω Concurrence input 1/2 ∞ Protective circuit/component Suppressor diode Input name Sensor circuit S1 S32, S42 Description of the input safety-related sensor inputs NPN Number of inputs 2 Input voltage range "0" signal 0 V DC ... 5 V DC Input voltage range "1" signal 11 V DC ... 30 V DC Input current range "0" signal 0 mA ... 2 mA Inrush current < 20 mA (typically with US) Current consumption < 5 mA (typically with US) Filter time max. 1.5 ms (Test pulse width of low test pulses) Test pulse rate = 5 x Test pulse width Deactivate switch-on pulses/light tests for safety applications. Max. permissible overall conductor resistance 150 Ω Concurrence input 1/2 ∞ Protective circuit/component Suppressor diode Input name Diagnostic input DGN Description of the input non-safety-related Number of inputs 1 Input voltage range 0 V DC ... 30 V DC Current consumption typ. 30 mA Protective circuit/component Suppressor diode Input name Start circuit S34 Description of the input NPN (manual start), PNP (autostart) Number of inputs 1 Input voltage range "1" signal 19.2 V DC ... 30 V DC (manual start, autostart: 0 V) Inrush current < 10 mA (typically with US, Δt = 100 ms) Current consumption < 5 mA (typically with US at S34/24 V) > -5 mA (typically with US at S34/0 V) Max. permissible overall conductor resistance 150 Ω Protective circuit/component Suppressor diode IO-Link inputs Designation IO-Link Specification Version 1.1 Transmission speed 230 kbps (COM3) 07/16/2019   Page 3 / 9 https://www.phoenixcontact.com/au/products/2702902 Safety relays - PSR-MC42-2NO-1DO-24DC-SP - 2702902 Technical data IO-Link inputs Cycle Time 5 ms Process data update 5 ms Amount of process data max. 31 Byte (Input data) max. 16 Byte (Output data) Number of ports 1 Connection method Spring-cage connection Connection technology 3-wire Port type Class A Input name C/Q Description of the input IO-Link switching and communication cable Number of inputs 1 Relay outputs: enabling current path Output name Enabling current path 13/14, 23/24 Output description safety-related N/O contacts 2 NO contacts each in series, without delay, floating Number of outputs 2 (undelayed) Contact type 2 enabling current paths Contact material AgSnO2 Switching voltage min. 12 V AC/DC max. 250 V AC/DC (Observe the load curve) Limiting continuous current 6A Inrush current min. 3 mA max. 6 A Sq. Total current 72 A (observe derating) Switching capacity min. 60 mW Switching frequency 0.5 Hz Mechanical service life 10x 10 cycles Switching capacity according to IEC 60947-5-1 4 A (24 V (DC13)) 2 6 5 A (250 V (AC15)) Output fuse 6 A gL/gG 4 A gL/gG (for low-demand applications) Alarm outputs Designation M1 Output description PNP non-safety-related Number of outputs 1 Voltage approx. 22 V DC (Us - 2 V) Current max. 100 mA 07/16/2019   Page 4 / 9 https://www.phoenixcontact.com/au/products/2702902 Safety relays - PSR-MC42-2NO-1DO-24DC-SP - 2702902 Technical data Alarm outputs Maximum inrush current 500 mA (Δt = 1 ms at Us) Protective circuit/component Suppressor diode Times Typical pickup time at US < 250 ms (when controlled via A1) Typical response time at US < 220 ms (automatic start) < 175 ms (manual, monitored start) Typical release time at US < 20 ms (on demand via the sensor circuit) < 20 ms (on demand via A1) Restart time < 1 s (Boot time) Recovery time < 500 ms General Relay type Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) Nominal operating mode 100% operating factor Net weight 181.8 g Mounting position vertical or horizontal Mounting type DIN rail mounting Assembly instructions See derating curve Degree of protection IP20 Min. degree of protection of inst. location IP54 Housing material PBT Housing color yellow Operating voltage display 1 x green, yellow, red LED Status display 5 green LEDs Connection data Connection method Spring-cage connection pluggable Yes Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm Safety-related characteristic data Stop category 0 Designation IEC 61508 - High demand Safety Integrity Level (SIL) 3 Designation IEC 61508 - Low demand 07/16/2019   Page 5 / 9 https://www.phoenixcontact.com/au/products/2702902 Safety relays - PSR-MC42-2NO-1DO-24DC-SP - 2702902 Technical data Safety-related characteristic data Safety Integrity Level (SIL) 3 Designation EN ISO 13849 Performance level (PL) e (4 A DC13; 5 A AC15; 8760 switching cycles/year) Category 4 Designation EN 62061 Safety Integrity Level Claim Limit (SIL CL) 3 Standards and Regulations Designation Air clearances and creepage distances between the power circuits Standards/regulations DIN EN 60947-1 Rated insulation voltage 320 V 320 V Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing Safe isolation, reinforced insulation 4 kV between input circuit and enabling current path (13/14) and enabling current path (23/24) Degree of pollution 2 Overvoltage category II Shock 15g Vibration (operation) 10 Hz ... 150 Hz, 2g Conformance CE-compliant Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values Drawings Block diagram L+ L- IO-Link COM A1 A2 S11 S21 S12 S22 24V DC PSR-MC42 S0 13 23 14 24 K1 K2 PWR S1 C/Q DGN S34 S32 S42 M1 07/16/2019   Page 6 / 9 https://www.phoenixcontact.com/au/products/2702902 Safety relays - PSR-MC42-2NO-1DO-24DC-SP - 2702902 Circuit diagram 24 V DC F2 F1 F3 S3 UB FI1A FI1B PSR-CT S2 OV S1 DGN K3 Start FO1A FO1B K4 S21 S22 (GND) ) S12 ( ( ) S34 S32 S42 ( ) S11 ( ) (+) ( ) A1 L+ DGN 13 23 14 24 L+ IO-Link LMaster L- PSR-MC42 C/Q C/Q A2 M1 K3 K4 0V Classifications eCl@ss eCl@ss 5.1 27371901 eCl@ss 6.0 27371819 eCl@ss 8.0 27371819 eCl@ss 9.0 27371819 ETIM ETIM 5.0 EC001449 ETIM 6.0 EC001449 Approvals Approvals Approvals Functional Safety / Functional Safety / UL Listed / cUL Listed / cULus Listed Ex Approvals Approval details Functional Safety      968/FSP 1718.00/19 07/16/2019   Page 7 / 9 https://www.phoenixcontact.com/au/products/2702902 Safety relays - PSR-MC42-2NO-1DO-24DC-SP - 2702902 Approvals Functional Safety      01/205/5677.00/19 UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 140324 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 140324 cULus Listed       Accessories Accessories Safety switches Safety switch sensor - PSR-CT-C-SEN-1-8 - 2702972 Proximity safety circuit up to Cat. 4, PL e (EN ISO 13849), SIL 3 (IEC 61508), unicode sensor with RFID coding, model 4 (EN ISO 14119), automatic or manual start, integrated diagnostics, 24 V DC supply, IP69K, M12 connector     Safety switch sensor - PSR-CT-M-SEN-1-8 - 2702975 Proximity safety circuit up to Cat. 4, PL e (EN ISO 13849), SIL 3 (IEC 61508), multicode sensor with RFID coding, model 4 (EN ISO 14119), automatic or manual start, integrated diagnostics, 24 V DC supply, IP69K, M12 connector     Safety switch sensor - PSR-CT-F-SEN-1-8 - 2702976 Proximity safety circuit up to Cat. 4, PL e (EN ISO 13849), SIL 3 (IEC 61508), fixcode sensor with RFID coding, model 4 (EN ISO 14119), automatic or manual start, integrated diagnostics, 24 V DC supply, IP69K, M12 connector     07/16/2019   Page 8 / 9 https://www.phoenixcontact.com/au/products/2702902 Safety relays - PSR-MC42-2NO-1DO-24DC-SP - 2702902 Accessories Safety switch actuator - PSR-CT-C-ACT - 2702973 Proximity safety circuit up to Cat. 4, PL e (EN ISO 13849), SIL 3 (IEC 61508), coded actuator, compatible with all sensor coding types, supplied inductively via the sensor, IP69K     Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 07/16/2019   Page 9 / 9
2702902 价格&库存

很抱歉,暂时无法提供与“2702902”相匹配的价格&库存,您可以联系我们找货

免费人工找货