0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2702969

2702969

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    网络 交换机 - 托管型 8 个端口 IP20

  • 数据手册
  • 价格&库存
2702969 数据手册
https://www.phoenixcontact.com/us/products/2702969 Industrial Ethernet Switch - FL SWITCH 2206-2SFX - 2702969 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Managed Switch 2000, 6 RJ45 ports 10/100 Mbps, 2 SFP ports 100 Mbps, degree of protection: IP20 Why buy this product  Suitable for PROFINET and EtherNet/IP™ networks  Easy and fast startup and commissioning with the FL NETWORK MANAGER software  Configuration memory  RSTP  DHCP client, DHCP server (pool-based and port-based), DHCP option 82  VLANs  MRP (client and master)  Web-based management, SNMP  Slim design  -40°C ... +70°C ambient temperature Key Commercial Data Packing unit 1 STK GTIN GTIN 4055626444406 Weight per Piece (excluding packing) 440.000 g Custom tariff number 85176200 Country of origin Germany Technical data Note 07/19/2018   Page 1 / 10 https://www.phoenixcontact.com/us/products/2702969 Industrial Ethernet Switch - FL SWITCH 2206-2SFX - 2702969 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 45 mm Height 130 mm Depth 115 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) Air pressure (operation) 68 kPa ... 108 kPa (3000 m above sea level) Air pressure (storage/transport) 68 kPa ... 108 kPa (3000 m above sea level) Interfaces Interface 1 Ethernet (RJ45) No. of ports 6 (RJ45 ports) Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) Signal LEDs Data receive, link status Interface 2 SFP module No. of ports 2 (SFP ports) Transmission physics Depending on the SFP module Transmission speed 100 Mbps (full duplex) Transmission length up to 40 km (Depending on the fiber/SFP module used) Signal LEDs Data receive, link status Function Basic functions Store-and-forward switch, complies with IEEE 802.3 Management Web-based management (HTTP/HTTPS) SNMPv1/v2/v3 Command-line interface (Telnet, SSH) Diagnostic functions RMON History LLDP (Link Layer Discovery Protocol) SNMP-Traps 07/19/2018   Page 2 / 10 https://www.phoenixcontact.com/us/products/2702969 Industrial Ethernet Switch - FL SWITCH 2206-2SFX - 2702969 Technical data Function ACD (Address Conflict Detection) N:1-Portmirroring Filter functions Quality of Service (8 priority classes) Port-Priorisierung VLAN (up to 32 VLANs) IGMP Snooping (32 groups) IGMP Query Auto-Query-Port Extended Multicast Filtering MAC address table 8k Redundancy MRP (Media Redundancy Protocol) RSTP (Rapid Spanning Tree Protocol) FRD (Fast Ring Detection) Large Tree Support IP parameterization DHCP-Client DHCP Option 82 (Relay Agent) DHCP server (pool-based, port-based) BootP PROFINET device function PROFINET device PROFINET conformance class Conformance-Class B Time synchronization SNTP (Simple Network Time Protocol) Status and diagnostic indicators LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) Signal contact control voltage 24 V DC (typical) Signal contact control current 200 mA (1 minute, maximum) Network expansion parameters Cascading depth Network, linear, and star structure: any Maximum conductor length (twisted pair) 100 m Supply voltage Supply voltage 24 V DC (redundant) Residual ripple 3.6 VPP (within the permitted voltage range) Supply voltage range 12 V DC ... 57 V DC Typical current consumption 280 mA (at US = 24 V DC) Max. current consumption 1.4 A (At US = 12 V DC and 70°C ambient temperature) Current consumption 230 mA General 07/19/2018   Page 3 / 10 https://www.phoenixcontact.com/us/products/2702969 Industrial Ethernet Switch - FL SWITCH 2206-2SFX - 2702969 Technical data General Mounting type DIN rail Type AX Book type Net weight 439 g Housing material Polycarbonate fiber reinforced Note Support by phone or on-site (fee is charged) MTTF 491.44 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) 212.99 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) 24.97 Years (SN 29500 standard, temperature 70 °C, operating cycle 100 % (7 days a week, 24 hours a day)) Connection data Connection method Screw connection Conductor cross section solid min. 0.08 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.08 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 28 Conductor cross section AWG max. 16 Stripping length 7 mm Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Free from substances that could impair the application of coating Yes Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz ATEX  II 3G Ex nA IIC T4 Gc IECEx Ex nA IIC T4 Gc UL, USA UL 60079-0, Ed.6 / UL 60079-7, Ed.5 UL, Canada CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 Environmental Product Compliance China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values 07/19/2018   Page 4 / 10 https://www.phoenixcontact.com/us/products/2702969 Industrial Ethernet Switch - FL SWITCH 2206-2SFX - 2702969 Classifications eCl@ss eCl@ss 4.0 27250501 eCl@ss 4.1 27250501 eCl@ss 5.0 27250501 eCl@ss 7.0 19170106 eCl@ss 8.0 19170106 eCl@ss 9.0 19170106 ETIM ETIM 3.0 EC000734 ETIM 4.0 EC000734 ETIM 5.0 EC000734 ETIM 6.0 EC000734 UNSPSC UNSPSC 6.01 43172015 UNSPSC 7.0901 43201404 UNSPSC 11 43172015 UNSPSC 12.01 43201410 UNSPSC 13.2 43201410 Approvals Approvals Approvals ABS / EAC / UL Listed / cUL Listed / RINA / DNV GL / LR / BSH / cULus Listed Ex Approvals IECEx / ATEX / UL Listed / cUL Listed / cULus Listed Approval details ABS  EAC    http://www.eagle.org/eagleExternalPortalWEB/  17-HG1592765-PDA    RU CDE.A*30.B01735 07/19/2018   Page 5 / 10 https://www.phoenixcontact.com/us/products/2702969 Industrial Ethernet Switch - FL SWITCH 2206-2SFX - 2702969 Approvals UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 RINA    http://www.rina.org/en  ELE205816XG  http://exchange.dnv.com/tari/  TAA00000YV  http://www.lr.org/en  17/20056  http://www.bsh.de/de/index.jsp  Nr. 966     DNV GL   LR  BSH   cULus Listed  Accessories Accessories Configuration memory Program / configuration memory - FL SD FLASH/MRM - 2700270 Parameterization memory, plug-in, with MRM functionality     Data cable preassembled 07/19/2018   Page 6 / 10 https://www.phoenixcontact.com/us/products/2702969 Industrial Ethernet Switch - FL SWITCH 2206-2SFX - 2702969 Accessories FO patch cable - FL MM PATCH 1,0 LC-LC - 2989158 Assembled FO cable, break out cable, multimode fiberglass 50/125 µm (OM2), connector: LC/LC, degree of protection: IP20, for installation in cable ducts or control cabinets, length: 1 m     FO patch cable - FL SM PATCH 1,0 LC-LC - 2989187 Assembled fiber optic cable, break-out cable, fiberglass single mode 9/125 µm (OS2, Low Water Peak Fiber), connector: LC/LC, degree of protection: IP20, for installation in cable ducts or control cabinets, length: 1 m     Drivers and interfaces Software - FL SNMP OPC SERVER V3 - 2701139 SNMP-OPC server, German and English, for monitoring and configuration of SNMP-capable equipment in HMI and SCADA systems     End block End clamp - E/NS 35 N - 0800886 End clamp, width: 9.5 mm, color: gray     Mounting rail adapter 07/19/2018   Page 7 / 10 https://www.phoenixcontact.com/us/products/2702969 Industrial Ethernet Switch - FL SWITCH 2206-2SFX - 2702969 Accessories DIN rail adapter - FL DIN RA - 2891053 The FL DIN RA is installed in a standard, 19-inch rack (EIA-310-D, IEC 60297-3-100) to allow DIN rail mounted equipment to be rack mounted.     Network management software Software - FL NETWORK MANAGER BASIC - 2702889 FL Network Manager, SNMP-based configuration and firmware update software, for easy startup of Managed Switches     Software - FL VIEW 32 LITE - 2701744 FL VIEW, SNMP-based software in English, for the detection and display of Ethernet networks. 32 nodes (network devices) can be monitored in one Class C subnetwork with this version.     Parameterization memory Memory - SD FLASH 512MB - 2988146 Program and configuration memory, plug-in, 512 Mbyte.     Program / configuration memory - SD FLASH 2GB - 2988162 Program and configuration memory     07/19/2018   Page 8 / 10 https://www.phoenixcontact.com/us/products/2702969 Industrial Ethernet Switch - FL SWITCH 2206-2SFX - 2702969 Accessories Patch cable Patch cable - FL CAT6 PATCH 1,0 - 2891385 Patch cable, CAT6, pre-assembled, 1.0 m     PCB plug Printed-circuit board connector - FK-MCP 1,5/ 5-ST-3,81GY35BD1-5 - 1015782 PCB connector, number of positions: 5, pitch: 3.81 mm, connection method: Push-in spring connection, color: light gray, contact surface: Tin     MCVW 1,5/ 5-ST-3,81GY7035BD2DO - 1034096 PCB connector, number of positions: 5, pitch: 3.81 mm, connection method: Screw connection with tension sleeve, color: light gray, contact surface: Tin     Protective cap Dust protection - FL RJ45 PROTECT CAP - 2832991 Dust protection caps for RJ45 socket     SFP module 07/19/2018   Page 9 / 10 https://www.phoenixcontact.com/us/products/2702969 Industrial Ethernet Switch - FL SWITCH 2206-2SFX - 2702969 Accessories Media module - FL SFP FX - 2891081 The small form-factor plug-in module provides a fiber optic interface with a data transmission speed of 100  Mbps with a wavelength of 1310 nm (long).     Media module - FL SFP FX SM - 2891082 The small form-factor plug-in module provides a fiber optic interface with a data transmission speed of 100  Mbps with a wavelength of 1310 nm (long).     Media module - FL SFP FE WDM20-SET - 2702439 Fast Ethernet SFP WDM set for transmission up to a maximum of 20 km on a single fiber with a wavelength of 1310/1550 nm.     Phoenix Contact 2018 © - all rights reserved http://www.phoenixcontact.com 07/19/2018   Page 10 / 10
2702969 价格&库存

很抱歉,暂时无法提供与“2702969”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2702969
  •  国内价格 香港价格
  • 1+6472.654361+778.47969

库存:2