FO converter with integrated optical diagnostics, for DeviceNet™, CAN, CANopen® up to 800
kbps, extension/redundancy module, interfaces: 1 x FO (BFOC), 850 nm, for PCF/fiberglass
cable (multimode)
Product Description
The PSI-MOS-DNET... fiber optic transmission system enables DeviceNet™ and CANopen® users to benefit from simple and interference-free
networking based on fiber optics. In addition, bus cable short circuits only affect the specific potential segment concerned. This increases overall
availability, and improves flexibility when designing the bus topology. The use of fiber optic technology enables branch lines and star and tree
structures to be created. The 22.5 mm space-saving devices from the PSI-MOS-DNET CAN/FO... series feature an internal
backplane. The maximum network expansion that can be achieved (sum total of copper and fiber optic cables) essentially depends on the data rate
used.
Your advantages
• Data rates of up to 800 kbps, set via DIP switches
• Approved for use in zone 2
• Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
Commercial Data
Item number
2708096
Packing unit
1 pc
Minimum order quantity
1 pc
Sales Key
C19
Product Key
DNC213
Catalog Page
Page 433 (C-6-2019)
GTIN
4017918943219
Weight per Piece (including packing)
191.4 g
Weight per Piece (excluding packing)
107.98 g
Customs tariff number
85176200
Country of origin
DE
Nov 25, 2022, 7:50 AM
Page 1 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Technical Data
Notes
Utilization restriction
EMC note
EMC: class A product, see manufacturer's declaration in the
download area
Utilization restriction
CCCex note
Use in potentially explosive areas is not permitted in China.
Product properties
Product type
Media converter
MTBF
323 Years (Telcordia standard, 25°C temperature, 21% operating
cycle (5 days a week, 8 hours a day))
49 Years (Telcordia standard, 40°C temperature, 34.25%
operating cycle (5 days a week, 12 hours a day))
Electrical properties
Electrical isolation
VCC // CAN
Maximum power dissipation for nominal condition
2W
Test voltage data interface/power supply
1.5 kVrms (50 Hz, 1 min.)
Supply
Supply voltage range
10 V DC ... 30 V DC
Nominal supply voltage
24 V DC (in acc. with UL)
Typical current consumption
100 mA (24 V DC)
Max. current consumption
100 mA
Connection method
Pluggable COMBICON screw terminal block through basic
module
Connection data
Supply
Connection method
Pluggable COMBICON screw terminal block through basic
module
Tightening torque
0.56 Nm ... 0.79 Nm
Interfaces
Bit distortion, input
± 35 % (permitted)
Bit distortion, output
< 6.25 %
Signal
CAN
CANopen®
DeviceNet™
Data: optical FO
Transmit capacity, minimum
-17.9 dBm (50/125 µm)
-14.1 dBm (62,5/125 µm)
Nov 25, 2022, 7:50 AM
Page 2 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
-5.1 dBm (200/230 µm)
Transmission length incl. 3 dB system reserve
2800 m (With F-K 200/230 10 dB/km with quick mounting
connector)
4800 m (with F-G 50/125 2.5 dB/km)
4200 m (with F-G 62,5/125 3.0 dB/km)
Connection method
B-FOC (ST®)
Wavelength
850 nm
Minimum receiver sensitivity
-32.5 dBm (50/125 µm)
-32.5 dBm (62,5/125 µm)
-32.1 dBm (200/230 µm)
Transmission medium
PCF fiber
Multi-mode fiberglass
Data: CAN interface, in accordance with ISO/IS 11898 for DeviceNet, CAN, CANopen
Serial transmission speed
≤ 800 kbps
Connection method
Pluggable screw connection
Transmission length
≤ 5000 m (Dependent on the data rate and the protocol used)
Transmission medium
Copper
File format/coding
Bit stuffing, NRZ
Dimensions
Width
22.5 mm
Height
99 mm
Depth
114.5 mm
Material specifications
Material
PA 6.6-FR (Housing)
Cable / line
FO cable
Fiber types
200/230 µm
50/125 µm
62.5/125 µm
PCF fiber
Fiberglass
Environmental and real-life conditions
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
-20 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Altitude
≤ 5000 m (For restrictions, see the manufacturer's declaration for
altitude operation)
Permissible humidity (operation)
30 % ... 95 % (non-condensing)
Nov 25, 2022, 7:50 AM
Page 3 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Approval data
CE
Certificate
CE-compliant
ATEX
Identification
Note
II 3 G Ex nA nC IIC T4 Gc X
Please follow the special installation instructions in the
documentation!
ATEX, FO interface
Identification
II (2) G [Ex op is Gb] IIC
II (2) D [Ex op is Db] IIIC
Certificate
PTB 06 ATEX 2042 U
Note
Please follow the special installation instructions in the
documentation!
UL, USA / Canada
Identification
Class I, Zone 2, AEx nc IIC T5
Class I, Div. 2, Groups A, B, C, D
Corrosive gas test
Identification
ISA-S71.04-1985 G3 Harsh Group A
EMC data
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Noise emission
EN 55011
Noise immunity
EN 61000-6-2:2005
Electrostatic discharge
Standards/regulations
EN 61000-4-2
Electrostatic discharge
Contact discharge
± 6 kV
Discharge in air
± 8 kV
Comments
Criterion B
Electromagnetic HF field
Standards/regulations
EN 61000-4-3
Electromagnetic HF field
Field intensity
10 V/m
Comments
Criterion A
Fast transients (burst)
Standards/regulations
EN 61000-4-4
Fast transients (burst)
Input
2 kV (5 kHz)
Nov 25, 2022, 7:50 AM
Page 4 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Signal
2 kV (5 kHz)
Comments
Criterion B
Surge current load (surge)
Input
0.5 kV (42 Ω)
Signal
1 kV (2 Ω)
Comments
Criterion B
Conducted interference
Standards/regulations
EN 61000-4-6
Conducted interference
Comments
Criterion A
Voltage
10 V
Emitted interference
Standards/regulations
EN 55011
Comments
Class A, industrial applications
Criterion A
Normal operating behavior within the specified limits.
Criterion B
Temporary impairment to operational behavior that is corrected
by the device itself.
Mounting
Mounting type
DIN rail mounting
Nov 25, 2022, 7:50 AM
Page 5 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Drawings
Application drawing
B
FO
...64x
BE
FO
...64x
B
...64x
Linear structure
Line structure
Nov 25, 2022, 7:50 AM
Page 6 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Application drawing
BE E
BE E
B
B
BE E
B
FO
BE E
FO
B
B
B
Tree structure
Tree structure
Block diagram
*) Only in the basic module
Nov 25, 2022, 7:50 AM
Page 7 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Application drawing
BE
B
FO
B
BE
Branch line / redundant branch line
Branch line / redundant branch line
Nov 25, 2022, 7:50 AM
Page 8 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Application drawing
BE E E
BE BE
...20
BE
...20
FO
B
B
B
B
BE
BE
BE
Star structure / redundant star structure
Star structure / redundant star structure
Nov 25, 2022, 7:50 AM
Page 9 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Approvals
cUL Recognized
UL Recognized
ATEX
Approval ID: FILE E 238705
Approval ID: FILE E 238705
Approval ID: PTB 06 ATEX 2042U
Nominal Voltage UN
Nominal Current IN
Cross Section AWG
Cross Section mm2
-
-
ATEX
Approval ID: PxCIF06ATEX2708261X
UL Listed
Approval ID: FILE E 199827
cULus Recognized
Nov 25, 2022, 7:50 AM
Page 10 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Classifications
ECLASS
ECLASS-9.0
19170114
ECLASS-10.0.1
19170132
ECLASS-11.0
19170411
ETIM
ETIM 8.0
EC001467
UNSPSC
UNSPSC 21.0
43201500
Nov 25, 2022, 7:50 AM
Page 11 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the
manufacturer’s declaration available under “Downloads”
Nov 25, 2022, 7:50 AM
Page 12 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Accessories
FO cable
FO cable - PSM-LWL-HCS-RUGGED-200/230 - 2799885
https://www.phoenixcontact.com/us/products/2799885
PCF cable, duplex 200 µm/230 µm, by the meter without male connector, for
installation in stationary systems and machines
FO cable
FO cable - PSM-LWL-HCSO-200/230 - 2799445
https://www.phoenixcontact.com/us/products/2799445
PCF cable, duplex 200/230 µm, by the meter, without connector, for outdoor
installation
Nov 25, 2022, 7:50 AM
Page 13 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
FO cable
FO cable - PSM-LWL-GDM-RUGGED- 50/125 - 2799322
https://www.phoenixcontact.com/us/products/2799322
Fiber glass cable, duplex 50 µm/125 µm, by the meter, without male connector,
for installation in stationary systems and machines
FO cable
FO cable - PSM-LWL-GDO- 50/125 - 2799432
https://www.phoenixcontact.com/us/products/2799432
Fiberglass cable, duplex 50/125 µm, by the meter, without connector, for outdoor
installation
Nov 25, 2022, 7:50 AM
Page 14 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Assembly tool
Assembly tool - PSM-HCS-KONFTOOL/B-FOC - 2708465
https://www.phoenixcontact.com/us/products/2708465
HCS assembly kit for B-FOC(ST) quick mounting connectors, including stripping
blade, stripping pliers, aramide yarn scissors, fiber stripper, microscope, fiber
cleaving tool for standard HCS and HCS GI fibers, four B-FOC(ST) connectors
for standard HCS fiber, and documentation
Measuring instrument
Measuring instrument - PSM-FO-POWERMETER - 2799539
https://www.phoenixcontact.com/us/products/2799539
Fiber optic measuring case, consisting of an optical power meter, F-SMA, B-FOC
adapters, reference fibers and operating instructions
Nov 25, 2022, 7:50 AM
Page 15 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Fiber optic coupling
Fiber optic coupling - PSM-SET-BFOC-LINK/2 - 2799429
https://www.phoenixcontact.com/us/products/2799429
Coupling; set consisting of 2 couplings for connecting B-FOC plugs
D-SUB bus connector
D-SUB bus connector - SUBCON-PLUS-CAN - 2744694
https://www.phoenixcontact.com/us/products/2744694
D-SUB connector, 9-pos. female connector, two 35° cable entries to one terminal
block row, bus system: CAN, CANopen®, SafetyBUS p up to 1 Mbps, termination
resistor can be switched on via slide switch, pin assignment: 2, 3, 7; screw
connection terminal blocks
Nov 25, 2022, 7:50 AM
Page 16 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
D-SUB bus connector
D-SUB bus connector - SUBCON-PLUS-CAN/PG - 2708119
https://www.phoenixcontact.com/us/products/2708119
D-SUB connector, 9-pos. socket, 35° cable entry, bus system: CAN, CANopen®,
SafetyBUS p up to 1 Mbps, with PG D-SUB socket for connecting a
programming device, termination resistor can be switched on via slide switch, pin
assignment: 2, 3, 7, 9; screw terminal blocks
D-SUB bus connector
D-SUB bus connector - SUBCON-PLUS-CAN/AX - 2306566
https://www.phoenixcontact.com/us/products/2306566
D-SUB connector, 9-pos. female connector, axial version with two cable entries,
bus system: CAN, CANopen, SafetyBUS p; pin assignment: 2, 3, 7; screw
connection terminal blocks
Nov 25, 2022, 7:50 AM
Page 17 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Screwdriver
Screwdriver - SZS 0,4X2,5 VDE - 1205037
https://www.phoenixcontact.com/us/products/1205037
Screwdriver, slot-headed, VDE insulated, size: 0.4 x 2.5 x 80 mm, 2-component
grip, with non-slip grip
FO connectors
FO connectors - PSM-SET-B-FOC/4-HCS - 2708481
https://www.phoenixcontact.com/us/products/2708481
B-FOC (ST) connector set for PCF fiber, for self assembly consisting of 4 quick
mounting connectors with bend protection sleeve
Nov 25, 2022, 7:50 AM
Page 18 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
Bus system cable
Bus system cable - SAC-5P-920/... - 1511504
https://www.phoenixcontact.com/us/products/1511504
Bus system cable, CANopen®, DeviceNet™, 4-position halogen-free, shielded,
cable length: Free entry (0.5 ... 400 m)
D-SUB bus connector
D-SUB bus connector - SUBCON-PLUS-CAN/90/PG/M12 - 2902322
https://www.phoenixcontact.com/us/products/2902322
D-SUB plug, 9-pos., socket, with PG-D-SUB pin, assignment: 2, 3, 5, 6, 7, 9; two
90° cable entries M12 (A-coded). Bus system: CAN, CANopen®. Termination
resistor via separate M12 terminator.
Nov 25, 2022, 7:50 AM
Page 19 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
D-SUB bus connector
D-SUB bus connector - SUBCON-PLUS-CAN/90/M12 - 2902323
https://www.phoenixcontact.com/us/products/2902323
D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two 90° cable entries
M12 (A-coded). Bus system: CAN, CANopen®. Termination resistor via separate
M12 terminator. Long version; S7-compatible.
D-SUB bus connector
D-SUB bus connector - SUBCON-PLUS-CAN/35/PG/M12 - 2902324
https://www.phoenixcontact.com/us/products/2902324
D-SUB plug, 9-pos., socket, with PG-D-SUB pin, assignment: 2, 3, 5, 6, 7, 9; two
35° cable entries M12 (A-coded). Bus system: CAN, CANopen®. Termination
resistor via separate M12 terminator.
Nov 25, 2022, 7:50 AM
Page 20 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
D-SUB bus connector
D-SUB bus connector - SUBCON-PLUS-CAN/35/M12 - 2902325
https://www.phoenixcontact.com/us/products/2902325
D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two 35° cable entries
M12 (A-coded). Bus system: CAN, CANopen®. Termination resistor via separate
M12 terminator.
D-SUB bus connector
D-SUB bus connector - SUBCON-PLUS-CAN/AX/M12 - 2902326
https://www.phoenixcontact.com/us/products/2902326
D-SUB plug, 9-pos., socket, assignment: 2, 3, 5, 6, 7, 9; two M12 cable glands
(A-coded) under 180° (axial). Bus system: CAN, CANopen®. Termination
resistor via separate M12 terminator.
Nov 25, 2022, 7:50 AM
Page 21 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
FO patch cable
FO patch cable - FOC-HCS-RUGGED-1014/IP20/... - 2901555
https://www.phoenixcontact.com/us/products/2901555
Robust PCF installation cable for assembly (IP20 heads only) for installation in
stationary systems and machines, aramid strain relief elements, with individual
elements made from FRNC material, halogen-free, ozone and UV resistant, with
a polyurethane (PUR) outer sheath
FO patch cable
FO patch cable - FOC-HCS-RUGGED-1014/... - 1402191
https://www.phoenixcontact.com/us/products/1402191
rugged PCF installation cable for inner areas with highly tear-proof aramid strainrelief elements. Individual elements made from highly flexible FRNC material.
The cable is halogen-free, ozone and UV resistant and has a rugged
polyurethane (PUR) outer sheath.
Nov 25, 2022, 7:50 AM
Page 22 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
FO patch cable
FO patch cable - FOC-HCSO-1015/IP20/... - 2901557
https://www.phoenixcontact.com/us/products/2901557
Highly rugged PCF round cable (IP20 heads only) for assembly and for outdoor
installation with integrated moisture barrier as well as rodent-proof scrim.
Individual elements made from highly flexible FRNC material. The wire is ozone
and UV resistant with a very rugged polyethylene outer sheath.
FO patch cable
FO patch cable - FOC-GDM-RUGGED-1016/IP20/... - 2901558
https://www.phoenixcontact.com/us/products/2901558
Robust GOF installation cable for assembly (IP20 heads only) for installation in
stationary systems and machines, aramid strain-relief elements, with individual
elements made from FRNC material, halogen-free, ozone and UV resistant, with
a polyurethane (PUR) outer sheath
Nov 25, 2022, 7:50 AM
Page 23 (24)
FO converters - PSI-MOS-DNET CAN/FO 850/EM
2708096
https://www.phoenixcontact.com/us/products/2708096
FO patch cable
FO patch cable - FOC-GDO-1017/IP20/... - 2901559
https://www.phoenixcontact.com/us/products/2901559
Highly rugged GOF round cable (IP20 heads only) for assembly and for outdoor
installation with integrated moisture barrier as well as rodent-proof scrim.
Individual elements made from highly flexible FRNC material. The wire is ozone