https://www.phoenixcontact.com/us/products/2708326
FO converters - PSI-MOS-RS485W2/FO 850 T - 2708326
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
FO converter with integrated optical diagnostics, alarm contact, for RS-485 2-wire bus systems (SUCONET K,
Modbus ...) up to 500 kbps, NRZ coding, T-coupler with two FO interfaces (BFOC), 850 nm, for PCF/fiberglass
cable (multimode)
Product Features
■
■
■
■
■
■
■
■
■
■
■
Supply voltage and data signals routed through via DIN rail connectors
Connections can be plugged in using a COMBICON screw terminal block
Can be combined with the PSI copper repeater in a modular way using DIN rail connectors
Automatic data rate detection or fixed data rate setting via DIP switches
Redundant power supply possible by means of optional system power supply unit
High-quality electrical isolation between all interfaces (RS-485 // fiber optic ports // power supply // DIN rail connector)
Approved for use in zone 2
Integrated optical diagnostics for continuous monitoring of fiber optic paths
Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
Floating switch contact for leading alarm generation in relation to critical fiber optic paths
Suitable for data rates up to 500 kbps
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
249.0 g
Custom tariff number
85176200
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
03/14/2016 Page 1 / 8
https://www.phoenixcontact.com/us/products/2708326
FO converters - PSI-MOS-RS485W2/FO 850 T - 2708326
Technical data
Dimensions
Width
35 mm
Height
99 mm
Depth
105 mm
Ambient conditions
Ambient temperature (operation)
-20 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
30 % ... 95 % (non-condensing)
Altitude
5000 m (For restrictions see manufacturer's declaration)
Degree of protection
IP20
Noise immunity
EN 61000-6-2:2005
General
Bit delay
≤ 1 Bit
Bit distortion, input
± 35 % (permitted)
Bit distortion, output
< 6.25 %
Electrical isolation
VCC // RS-485
Test voltage data interface/power supply
1.5 kVrms (50 Hz, 1 min.)
Electromagnetic compatibility
Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) /
2014/30/EU (valid from 20.04.2016)
Noise emission
EN 55011
Net weight
210.08 g
Housing material
PA 6.6-FR
Color
green
MTBF
159 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5
days a week, 8 hours a day))
24 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle
(5 days a week, 12 hours a day))
Conformance
CE-compliant
ATEX
II 3 G Ex nAC IIC T4 X (Please follow the special installation instructions
in the documentation!)
II (2) GD [Ex op is] IIC (PTB 06 ATEX 2042 U) (Please follow the special
installation instructions in the documentation!)
UL, USA / Canada
Class I, Zone 2, AEx nc IIC T5
Class I, zone 2, Ex nC nL IIC T5 X
Class I, Div. 2, Groups A, B, C, D
Power supply
Nominal supply voltage
24 V DC (With UL approval)
Supply voltage range
18 V DC ... 30 V DC
03/14/2016 Page 2 / 8
https://www.phoenixcontact.com/us/products/2708326
FO converters - PSI-MOS-RS485W2/FO 850 T - 2708326
Technical data
Power supply
Max. current consumption
130 mA
Typical current consumption
120 mA (24 V DC)
Connection method
COMBICON plug-in screw terminal block
Serial interface
Interface 1
RS-485 interface, 2-wire
Operating mode
Semi-duplex
Connection method
Pluggable screw connection
File format/coding
UART (11/10 bit switchable; NRZ), slip-tolerant
Data direction switching
Automatic control
Transmission medium
Copper
Transmission length
≤ 1200 m (depending on the data rate, with shielded, twisted data cable)
Termination resistor
390 Ω
220 Ω
390 Ω (Can be connected)
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Serial transmission speed
4.8/ 9.6/ 19.2/ 38.4/ 57.6/ 75/ 93.75/ 115.2/ 136/ 187.5/ 375/ 500 kbps
Optical interface FO
Transmit capacity, minimum
-4 dBm (200/230 µm)
-17.6 dBm (50/125 µm)
-14 dBm (62,5/125 µm)
Minimum receiver sensitivity
-32.5 dBm (50/125 µm)
-32.5 dBm (62,5/125 µm)
-32.1 dBm (200/230 µm)
Overrange receiver
-3 dBm (200/230 µm)
Wavelength
850 nm
Transmission length incl. 3 dB system reserve
2800 m (with F-K 200/230 8 dB/km with quick mounting connector)
4200 m (with F-G 50/125 2.5 dB/km)
3300 m (with F-G 62,5/125 3.0 dB/km)
Transmission medium
PCF fiber
Multi-mode fiberglass
Transmission protocol
Protocol-transparent to the RS-485 interface
03/14/2016 Page 3 / 8
https://www.phoenixcontact.com/us/products/2708326
FO converters - PSI-MOS-RS485W2/FO 850 T - 2708326
Technical data
Optical interface FO
Connection method
®
B-FOC (ST )
Digital outputs
Output name
Relay output
Output description
Alarm output
Number of outputs
1
Maximum switching voltage
60 V DC
42 V AC
Limiting continuous current
0.46 A
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) /
2014/30/EU (valid from 20.04.2016)
Type of test
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result
5g, 10-150 Hz, 2.5 h, in XYZ direction
Type of test
Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result
15g, 11 ms period, half-sine shock pulse
Shock
15g in all directions in acc. with IEC 60068-2-27
Noise emission
EN 55011
Noise immunity
EN 61000-6-2:2005
Free from substances that could impair the application of coating
according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Connection in acc. with standard
CUL
Standards/regulations
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
Vibration (operation)
In acc. with IEC 60068-2-6: 5g, 150 Hz
Conformance
CE-compliant
ATEX
II 3 G Ex nAC IIC T4 X
II (2) GD [Ex op is] IIC (PTB 06 ATEX 2042 U)
UL, USA / Canada
Class I, Zone 2, AEx nc IIC T5
Class I, zone 2, Ex nC nL IIC T5 X
Class I, Div. 2, Groups A, B, C, D
Classifications
eCl@ss
eCl@ss 4.0
27230207
eCl@ss 4.1
27230207
03/14/2016 Page 4 / 8
https://www.phoenixcontact.com/us/products/2708326
FO converters - PSI-MOS-RS485W2/FO 850 T - 2708326
Classifications
eCl@ss
eCl@ss 5.0
27230207
eCl@ss 5.1
27230207
eCl@ss 6.0
27230207
eCl@ss 7.0
27230207
eCl@ss 8.0
19179290
ETIM
ETIM 2.0
EC001423
ETIM 3.0
EC001423
ETIM 4.0
EC001423
ETIM 5.0
EC000310
UNSPSC
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
43201553
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / DNV / EAC / EAC / KC / cULus Recognized
Ex Approvals
ATEX / UL Listed / cUL Listed / ATEX / cULus Listed
Approvals submitted
Approval details
UL Recognized
03/14/2016 Page 5 / 8
https://www.phoenixcontact.com/us/products/2708326
FO converters - PSI-MOS-RS485W2/FO 850 T - 2708326
Approvals
cUL Recognized
DNV
EAC
EAC
KC
cULus Recognized
Drawings
Application drawing
Application drawing
Max. 31
E
Max. 31
E
Max. 31
FO
T
Max. 31
T
FO
FO
E
T
Max. 31
Point-to-point connection
Max. 31
T
Max. 31
Redundant
point-to-point connection
FO
Linear structure
Redundant point-to-point connection
03/14/2016 Page 6 / 8
https://www.phoenixcontact.com/us/products/2708326
FO converters - PSI-MOS-RS485W2/FO 850 T - 2708326
Application drawing
Application drawing
max. 31
Max. 31
T
T
E
T
T
...
...
FO
FO
E
E
E
E
max. 31
max. 31
max. 31
max. 31
E
T
T
...
T
T
...
T
T
...
T
T
...
Max. 31
Star structure
Tree structure
FO
Redundant structure
Application drawing
max. 31
T
T
T
...
FO
T
T
T
max. 31 max. 31 max. 31
Redundant structure
Tree structure
03/14/2016 Page 7 / 8
https://www.phoenixcontact.com/us/products/2708326
FO converters - PSI-MOS-RS485W2/FO 850 T - 2708326
Block diagram
24V (1)
COMBICON
0V (2)
DC
TD
gn
DC
FO Line
Retiming
11 (3)
Alarm
12 (4)
SHD
FO Port A
RD
rd
ERR A
Line Diagnostics Port A
(5)
GND (6)
390 220 390
CTRL
Bus Management
Function/
Data Rate
D(B) (7)
ye
D(A) (8)
gn
Retiming
Line Diagnostics Port B
TD
FO Line
Retiming
rd
FO Port B*)
RD
ERR B
24 V 0 V GND Data Data
B
A
DIN Rail Connector
*) only for PSI-MOS-RS485 W2/FO...T
*) only with PSI-MOS.../FO...T
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
03/14/2016 Page 8 / 8