    BUS COUPLER 24VDC

  • 数据手册
  • 价格&库存
2718785 数据手册
Extract from the online catalog     IL DN BK3-PAC Order No.: 2718785 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2718785     DeviceNet™ bus coupler, 24 V DC, without accessories Commercial data GTIN (EAN) 4 017918 890049 sales group K410 Pack 1 pcs. Customs tariff 85176200 Catalog page information Page 257 (AX-2009) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Product description The DeviceNet™ fieldbus coupler enables the flexible INTERBUS Inline automation kit to be operated with DeviceNet™ as well. The fieldbus coupler allows an INTERBUS Inline station to be inserted at any point in a DeviceNet™ network. The fieldbus coupler is a slave in the DeviceNet™ and a master in the lower-level INTERBUS Inline local bus. The address of the DeviceNet™ slave can easily be set from outside by means of DIP switches. DeviceNet™ is connected via a Twin Combicon connector. The operating voltage for the fieldbus coupler and the electronics can be fed using a separate power connector. For the DeviceNet™ project planning, a regularly updated EDS file (Electronica Data Sheet) is provided in the Product Information Service (see below). The DeviceNet™ fieldbus coupler supports the proven INTERBUS Inline diagnostics as well as the typical diagnostics objects for the DeviceNet. Local LEDs enable precise diagnostics. Please note the following when you configure the system: PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 5 Feb 7, 2011 IL DN BK3-PAC Order No.: 2718785 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2718785 The total logic current of all terminals connected to a DeviceNet™ fieldbus coupler must not exceed the maximum permissible total current of 2 A. Therefore, depending on your configuration, the number of terminal blocks that you can connect may be less than 63. Technical data General data Width 85 mm Height 119.8 mm Depth 71.5 mm Weight 240 g Note on weight specifications with male connectors Mounting type DIN rail Ambient temperature (operation) -25 °C ... 55 °C Ambient temperature (storage/transport) -45 °C ... 85 °C Permissible humidity (operation) 95 % (no condensation) Permissible humidity (storage/transport) 85 % (no condensation) Air pressure (operation) 80 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3500 m above mean sea level) Degree of protection IP20 Interface Fieldbus system Lokalbus Name Inline local bus Type of connection Inline data jumper Transmission speed 500 kBaud Fieldbus system DeviceNet™ Name DeviceNet™ Type of connection 2x 5-pos. TWIN-COMBICON connectors Transmission speed 500 kBaud, 250 kBaud, 125 kBaud (Can be set via DIP switch or programmed) Number of positions 10 Name Supply Type of connection 8-pos. Inline connector Power supply for module electronics Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC Supply current Typ. 100 mA (No local bus devices connected) PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 2 / 5 Feb 7, 2011 IL DN BK3-PAC Order No.: 2718785 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2718785 Current consumption max. 1.25 A Inline potential routing Communications power UL 7.5 V DC ±5% Power supply at UL max. 2 A DC (observe derating) Main circuit supply UM 24 V DC -15% / +20% (in acc. with EN 61131-2) Power supply at UM max. 8 A DC (Sum of UM + US) Segment supply voltage US 24 V DC -15% / +20% (in acc. with EN 61131-2) Power supply at US max. 8 A DC (Sum of UM + US) I/O supply voltage UANA 24 V DC -15% / +20% Power supply at UANA max. 0.5 A DC (observe derating) Certificates / Approvals Certification CUL, GOST, UL Certification Ex: CUL-EX LIS, UL-EX LIS Accessories Item Designation Description CLIPFIX 35 Snap-on end bracket, for 35 mm NS 35/7.5 or NS 35/15 DIN rail, can be fitted with Zack strip ZB 8 and ZB 8/27, terminal strip marker KLM 2 and KLM, width: 9.5 mm, color: gray 0809492 ESL 62X10 Insert strip for laser printer, lettering field: 62 x 10 mm 2727501 IB IL FIELD 2 Labeling field, width: 12.2 mm IB IL SCN-8-CP Inline connector, colored Assembly 3022218 Marking Plug/Adapter 2727608 PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 3 / 5 Feb 7, 2011 IL DN BK3-PAC Order No.: 2718785 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2718785 Diagrams/Drawings Connection diagram Block diagram Dimensioned drawing FAQs • How does the autoconfiguration function of the local bus work on the IL DN BK 3 fieldbus coupler? The autoconfiguration function allows the bus coupler to be configured inn the field without any software. The default settings with this function are: - Two bytes are added to the input process data as Inline status word (diagnostic word). - All the digital, analog and function blocks are added to the process data. - No wildcards are added for future system extensions. The following process describes how to use the autoconfiguration function: 1. Set DIP switches 1 to 7 to the desired address and DIP switches 8 to 9 to the desired baudrate. 2. Then turn the power supply fore the network and UL off and then back on again. Please note that after decompression for the initial startup the new address and the baudrate are automatically saved in the memory of the bus coupler. 3. Switch off the power supply at the bus coupler. 4. Set DIP switch 10 to "ON" 5. Check that all the necessary I/O modules are connected. 6. Switch the power supply of the bus coupler back on. At this point, the "MD" LED on the bus coupler and the "D" LED on the input/output modules start flashing. As soon as the flashing stops and the LEDs are permanently lit up, the process of saving the local bus configuration of the bus coupler is complete. PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 4 / 5 Feb 7, 2011 IL DN BK3-PAC Order No.: 2718785 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2718785 Address PHOENIX CONTACT Inc., USA 586 Fulling Mill Road Middletown, PA 17057,USA Phone (800) 888-7388 Fax (717) 944-1625 http://www.phoenixcon.com © 2011 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 5 / 5 Feb 7, 2011
2718785 价格&库存

很抱歉,暂时无法提供与“2718785”相匹配的价格&库存,您可以联系我们找货

免费人工找货