0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2719962

2719962

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    IBSS7400DSC/I-T

  • 数据手册
  • 价格&库存
2719962 数据手册
https://www.phoenixcontact.com/us/products/2719962 Termination board - IBS S7 400 DSC/I-T - 2719962 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) ® Termination board for Siemens SIMATIC S7 400 PLCs, with electrical isolation Product Description INTERBUS controller boards for Siemens SIMATIC S7-400 PLCs The IBS S7 400 DSC/I-T board connects the SIMATIC S7 400 PLC with INTERBUS. After power-up the INTERBUS configuration is read in automatically and started with the specified parameters. The system-specific parameterization of the bus system and the controller board is undertaken using the easy-to-use IBS CMD software and then stored in a flash memory card. The following range of functions is supported: - Preprocessing of process data - Synchronous operating modes - Parameterization of alternative and changing bus segments - Parameterization using CMD - Startup using "Plug & Play" technology For displaying the comprehensive INTERBUS system diagnostics, the controller board is equipped with a four-line LC display in which operating and error states are shown in plain text. The INTERBUS system is controlled using a function register which triggers control functions (switching devices on and off or bypassing devices, clearing the diagnostics display) simply by setting outputs. Simple operation and efficient diagnostics facilitate startup and increase the availability of the system. The base of the housing can be concealed behind a cover once parameterization and startup of the controller board have been completed. Why buy this product  Blocks for STEP 7 simplify integration  INTERBUS with up to 8192 I/O points per controller board  Maximum INTERBUS transmission speed of 2 Mbaud Key Commercial Data Packing unit 1 STK Weight per Piece (excluding packing) 1,026.500 g Custom tariff number 85389091 Country of origin Germany 09/02/2016   Page 1 / 7 https://www.phoenixcontact.com/us/products/2719962 Termination board - IBS S7 400 DSC/I-T - 2719962 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 50 mm Height 290 mm Depth 210 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) 0 °C ... 60 °C Ambient temperature (storage/transport) -25 °C ... 65 °C Permissible humidity (operation) 30 % (up to 75%, no condensation) Permissible humidity (storage/transport) 30 % (up to 95%, no condensation) Air pressure (operation) 860 hPa ... 1080 kPa (up to 1500 m above sea level) Air pressure (storage/transport) 660 hPa ... 1080 kPa (up to 3500 m above sea level) Control system Control system SIMATIC® S7-400 controllers Programming tool STEP 7 from version 5.x Diagnostics tool DIAG+ from version 1.0x Configuration tool CMD from Version 4.0x Software interfaces Application interface S7 I/O driver S7 function blocks Software requirements Configuration tool CMD from Version 4.0x Config+ from version 1.00 onwards Diagnostics tool DIAG+ from version 1.0x Programming tool STEP 7 from version 5.x Power supply Power supply connection Via SIMATIC I/O bus Typical current consumption 0.9 A Supply voltage 5 V DC Power dissipation max. 4.5 W General Weight 1026 g 09/02/2016   Page 2 / 7 https://www.phoenixcontact.com/us/products/2719962 Termination board - IBS S7 400 DSC/I-T - 2719962 Technical data General Format 2 slots Data interfaces Interface Control system Connection method SIMATIC S7-400 P-Bus Interface INTERBUS remote bus Connection method 9-pos. D-SUB socket strip Transmission speed 500 kBit/s / 2 MBit/s Interface Parameterization/operation/diagnostics Connection method RS-232-C, D-SUB male connector Interrupts Are supported ® Fieldbus function Amount of process data max. 8192 Bit Number of supported devices max. 128 (of which 254 are remote bus devices/bus segments) Number of devices with parameter channel max. 126 (512 words) Standards and Regulations Connection in acc. with standard CUL Classifications eCl@ss eCl@ss 4.0 27240409 eCl@ss 4.1 27240409 eCl@ss 5.0 27242215 eCl@ss 5.1 27242208 eCl@ss 6.0 27242208 eCl@ss 7.0 27242208 eCl@ss 8.0 27242208 eCl@ss 9.0 27242208 ETIM ETIM 2.0 EC001423 ETIM 3.0 EC001423 ETIM 4.0 EC001423 ETIM 5.0 EC001423 09/02/2016   Page 3 / 7 https://www.phoenixcontact.com/us/products/2719962 Termination board - IBS S7 400 DSC/I-T - 2719962 Classifications UNSPSC UNSPSC 6.01 43172015 UNSPSC 7.0901 43201404 UNSPSC 11 43172015 UNSPSC 12.01 43201404 UNSPSC 13.2 43201404 Approvals Approvals Approvals UL Recognized / cUL Recognized / EAC / cULus Recognized Ex Approvals Approval details UL Recognized   http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 140324     Nominal current IN 0.415 A Nominal voltage UN 5V cUL Recognized   http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 140324     Nominal current IN 0.415 A Nominal voltage UN 5V EAC   EAC-Zulassung cULus Recognized   http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm 09/02/2016   Page 4 / 7 https://www.phoenixcontact.com/us/products/2719962 Termination board - IBS S7 400 DSC/I-T - 2719962 Accessories Accessories Configuration and diagnostics Software - DIAG+ - 2730307 Diag+, diagnostics software, for INTERBUS networks, area of application: Startup, maintenance and, for example, for integration in control desk software, can be integrated in 32 bit applications (ActiveX-capable)     Software - CONFIG+ OEM - 2700779 Config+ project license, for configuration and diagnostics of an INTERBUS system. Please enter the project number in the configuration field or get in touch with your contact person in our sales organization.     Software - CONFIG+ DEMO - 2868046 Config+ demo version with restricted range of function (it is not possible to save projects)     Software - CONFIG+ - 2868059 Config+ full version for configuration and diagnostics of an INTERBUS system     Software - CONFIG+ CPY - 2868062 The Config+ copy license enables the installation and parallel use of the Config+ software on multiple workstations. A single-user full license is also required. It is a workstation license     09/02/2016   Page 5 / 7 https://www.phoenixcontact.com/us/products/2719962 Termination board - IBS S7 400 DSC/I-T - 2719962 Accessories Software - IBS CMD SWT G4 - 2721439 Network configuration software for INTERBUS Generation 4     Software - IBS CMD SWT G4 E - 2721442 Network configuration software for INTERBUS Generation 4     Device parameterization Software - AX+ BASIC - 2985068 Software CD for FDT container for integrating device DTMs (free download)     Software - AX DTM LIB - 2988065 DTM library     Parameterization memory 09/02/2016   Page 6 / 7 https://www.phoenixcontact.com/us/products/2719962 Termination board - IBS S7 400 DSC/I-T - 2719962 Accessories Memory - IBS MC FLASH 2MB - 2729389 Program and configuration memory, 2 Mbyte     Programming cable Connecting cable - IBS PRG CAB - 2806862 Connection cable, to connect the controller boards to the PC (RS-232-C), length 3 m     Spare parts Memory - IBS MC FLASH 2MB - 2729389 Program and configuration memory, 2 Mbyte     Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 09/02/2016   Page 7 / 7
2719962 价格&库存

很抱歉,暂时无法提供与“2719962”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2719962

    库存:0