0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2725260

2725260

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    PCI MASTER CONTROLLER BOARD

  • 数据手册
  • 价格&库存
2725260 数据手册
Extract from the online catalog     IBS PCI SC/I-T Order No.: 2725260 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2725260     PCI master controller board with electrical isolation Product notes WEEE/RoHS-compliant since: 03/27/2008 Commercial data GTIN (EAN) 4 017918 185121 sales group K020 Pack 1 pcs. Customs tariff 84733020 Catalog page information Page 122 (AX-2009) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Product description INTERBUS Generation 4 controller board for PCs The IBS PCI SC/I-T standard controller also provides compatible extension of the high-level language programmable ISA bus platform toward the PCI. The corresponding Interbus configurator CMD forms the central interface to all the other tools involved in an automation solution, such as EPLAN, visualization, and programming. Highly integrated interfaces, such as HLI and OPC offer direct access to the INTERBUS fieldbus system and the runtime system of the controller. Free drivers for Windows NT round off the range of products. PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 6 Feb 7, 2011 IBS PCI SC/I-T Order No.: 2725260 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2725260 The drivers are not part of the scope of delivery for the board. The necessary software is on the CD and in the User Manual, or you can download it from this page. The system packages offered include an economy version consisting of the controller board, the manuals, all the drivers, (incl. HLI, but w/o OPC server) and CMD G4. Technical data Control system Control system IBM-compatible PCs with PCI slot Diagnostics tool DIAG+ from version 1.0x Configuration tool CMD from version 4.5x Software interfaces Software driver Windows NT Windows 2000 Windows XP Windows 7 Venturcom RTX 5.x Further types on request Application interface HFI OPC DDI Software requirements Configuration tool CMD from version 4.5x Config+ from version 1.00 onwards Diagnostics tool DIAG+ from version 1.0x Power supply Power supply connection Via PCI bus Typical current consumption 0.7 A Supply voltage 5 V DC Supply voltage range ± 5 % (including ripple) General data Weight 150 g Format Short plug-in card, 1-slot Height 107 mm Depth 168 mm PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 2 / 6 Feb 7, 2011 IBS PCI SC/I-T Order No.: 2725260 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2725260 Degree of protection IP00 Ambient temperature (operation) 0 °C ... 55 °C (in acc. with EN 60204-1) Ambient temperature (storage/transport) -25 °C ... 75 °C (in acc. with EN 60204-1) Permissible humidity (operation) 75 % (on average, 85% infrequently, no condensation) Air pressure (operation) 860 hPa ... 1080 hPa (up to 2000 m above mean sea level) Air pressure (storage/transport) 660 hPa ... 1080 hPa (up to 3000 m above sea level) Data interfaces Interface INTERBUS remote bus Type of connection 9-pos. D-SUB female connector, with electrical isolation Interface Parameterization/operation/diagnostics Type of connection RS-232-C, Mini-DIN female Interface Host system Type of connection PCI bus, 32 bit, 33 MHz, 5 V Interface Direct I/Os Type of connection 14-pos. FLK pin strip Interrupts 1 IRQ, PnP INTERBUS data Type INTERBUS master Number of devices with parameter channel (PCP) max. 126 (512 words) Number of PCP data max. 126 Number of supported devices max. 512 (of which 254 are remote bus devices/bus segments) Number of I/O nodes max. 8192 Direct I/Os 6 inputs, 2 outputs Certificates / Approvals Certification PHOENIX CONTACT Inc., USA http://www.phoenixcon.com CUL, GOST, UL Page 3 / 6 Feb 7, 2011 IBS PCI SC/I-T Order No.: 2725260 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2725260 Accessories Item Designation Description Cable/conductor 2288901 FLK 14/EZ-DR/ 50/KONFEK Round cable set, with two 14-pos. socket strips (1:1 connection), for connecting 8 channels, cable length: 0.5 m 2985589 CD PC DRIVER Driver software and documentation on CD-ROM (German and English) 2962557 UM 45-FLK14 VARIOFACE module, with screw connection and flat-ribbon cable connector, for assembly on NS 35/7.5, 14 positions PRG CAB MINI DIN Connection cable, to connect Remote Field Controllers to a PC (RS-232) for PC WORX, 3 m in length 2737423 CD IBS PCI SC RTX Driver and documentation CD incl. Driver as RTDLL, coupling driver for parallel Windows access and HLI interface as RTDLL, incl. online documentation (as development licence) 2730307 DIAG+ Diag+, diagnostics software, for INTERBUS networks, area of application: Startup, maintenance and, for example, for integration in control desk software, can be integrated in 32 bit applications (ActiveX-capable) 2721439 IBS CMD SWT G4 Network configuration software for INTERBUS Generation 4 2721442 IBS CMD SWT G4 E Network configuration software for INTERBUS Generation 4 2729127 IBS OPC SERVER INTERBUS OPC server, communication interface between distributed INTERBUS and Ethernet networks and visualizations. 2730271 IBS PCI DDK Device driver development kit, for the development of device drivers for individual operating system (German, English) General Plug/Adapter 2730611 Software FAQs • Driver update under Windows 2000 (Beta->1.08). Driver parameters are not properly updated. To access the Windows 2000 driver for INTERBUS controller boards IBS PCI SC... with IBS CMD SWT G4 (E) some system parameters have to be updated. Please follow these steps: 1. Uninstall the hardware "PCI-MPM Interbus Controller" with the hardware assistant under Control Panel 2. Delete any files in " \INF" e.g. "C:\WINNT\INF" similar to OEM?.INF, OEM??.INF, OEM?.PNF and OEM??.PNF (for example: OEM0.INF, OEM1.INF, OEM2.INF...OEM10.INF, OEM11.INF, OEM12.INF... and OEM0.PNF, OEM1.PNF, OEM2.PNF...OEM10.PNF, OEM11.PNF, OEM12.PNF...). If none of those files appear, you will need to change your file "View" in Windows Explorer: Within Explorer, choose: Tools - Folder Options - View: Select "show hidden files and folders" and make sure "hide file extensions for known file types" is unchecked. 3. Install the new driver using the hardware assistant. PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 4 / 6 Feb 7, 2011 IBS PCI SC/I-T Order No.: 2725260 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2725260 • Is it possible to implement a bus parameterization with isolated disconnection if an incorrect bus is connected? Yes, it is possible. Before a bus start it however is necessary to activate the configuration frame. Activate configuration frame: Code: 0711 Parameter_Count: 0001 Frame_Reference: 0001 Start bus: Code: 0701 • The outputs on the controller board cannot be set using the process data monitor in CMD. When the driver is running, the driver application data is cyclically copied to the board memory. However, CMD writes the data using another channel. Therefore, the driver cyclically writes zeros into the output data. This behavior prevents output variables on INTERBUS from being set in the process data monitor using CMD. At present no remedy is possible. • Why is no data being transmitted to the controller board, even though the driver and mailbox interface are operating without errors? The problem: Despite the fact that the driver software has been started and INTERBUS is running, no process data can be copied. Communication with the board is possible via the mailbox. Possible cause and remedy: The controller board has been set manually or in the CMD project to asynchronous mode. However, the Windows NT driver only operates in asynchronous with synchronization pulse mode. Under CMD, check the bus operation menu item in the controller board settings. Here asynchronous with synchronization pulse must be selected as the default operating mode for the PCI controller boards. The correct operating mode must be set, especially when transferring existing projects e.g., from IBS PC ISA SC /I-T. PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 5 / 6 Feb 7, 2011 IBS PCI SC/I-T Order No.: 2725260 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2725260 Address PHOENIX CONTACT Inc., USA 586 Fulling Mill Road Middletown, PA 17057,USA Phone (800) 888-7388 Fax (717) 944-1625 http://www.phoenixcon.com © 2011 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 6 / 6 Feb 7, 2011
2725260 价格&库存

很抱歉,暂时无法提供与“2725260”相匹配的价格&库存,您可以联系我们找货

免费人工找货