2727352

2727352

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    MOTORSTARTMODULE24V

  • 数据手册
  • 价格&库存
2727352 数据手册
https://www.phoenixcontact.com/us/products/2727352 Inline terminal - IB IL 400 ELR 1-3A - 2727352 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Inline power-level terminal blocks, electronic direct starter, up to 1.5 kW / 400 V AC Product description INTERBUS Inline power-level terminals enable standard three-phase motors to be switched, protected, and monitored via INTERBUS. The terminals in the product range are available as direct and reversing starters in electronic and electromechanical versions. Each power-level terminal is equipped with electronic motor protection and provides the same advantages as the INTERBUS motor starter, such as motor current monitoring, overcurrent protection, and quick shutdown according to IEC. The integrated controller supports motor current parameterization via INTERBUS in the performance ranges from 15 W to 1.5 kW and 0.1 kW to 3.7 kW. As with all Inline automation terminals, the power-level terminals can be snapped on and mounted on a DIN rail without tools. Labeling is carried out directly on the module using the familiar zack marker strip and a snap-on label with large-surface labeling option. Additional features include: - Mains voltage up to 400 V AC 3~ - Mains output power: electronic: 15 W to 1.5 kW, electromechanical version: 0.1 kW to 3.7 kW - Manual local operation without bus supported - Can be extended with brake function as an option - Thermal motor monitoring using Inline thermistor terminal   Product Features  Connection option for an external passive brake module  Hand-held operator panel mode  Integrated electronic motor protection in accordance with IEC 60947-4  Diagnostic and status indicators  Safe isolation between mains voltage and 24 V supply voltage according to EN 50178  Motor current monitoring  Motor control via OUT process data Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 540.3 GRM Custom tariff number 85389091 Country of origin Germany Technical data Note 09/08/2014   Page 1 / 6 https://www.phoenixcontact.com/us/products/2727352 Inline terminal - IB IL 400 ELR 1-3A - 2727352 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 63 mm Height 224 mm Depth 109 mm Ambient conditions Ambient temperature (operation) -25 °C ... 55 °C Ambient temperature (storage/transport) -25 °C ... 85 °C Permissible humidity (operation) 10 % ... 85 % (In conformity with DIN EN 61131-2) Permissible humidity (storage/transport) 10 % ... 85 % (In conformity with DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above mean sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above mean sea level) Degree of protection IP20 Interfaces Fieldbus system Lokalbus Designation Inline local bus Connection method Inline data jumper Transmission speed 500 kBit/s Transmission physics Copper Power supply for module electronics Connection method Through the potential jumper Designation Terminal strips X11 and X12 Mains connection Designation Mains connection Connection method Power connector or power bridge Designation connection point Terminal strip; X11 and X12 Number of positions 5 Permissible conductor cross section max. 2.5 mm² (L1+L2+L3+N-PE) Operating voltage 187 V AC ... 440 V AC +0 % (conductor voltage) Max. current carrying capacity 20 A Motor starter, output Connection method (3-phase), via COMBICON Number 1 09/08/2014   Page 2 / 6 https://www.phoenixcontact.com/us/products/2727352 Inline terminal - IB IL 400 ELR 1-3A - 2727352 Technical data Motor starter, output Output name Motor outputs (three phases), short-circuit-proof with external line protection fuse 16 A Designation connection point Terminal strip; X10 Number of positions 4 Permissible conductor cross section 1 mm² ... 2.5 mm² Operating voltage 200 V AC ... 440 V AC Frequency range 50 Hz ... 60 Hz Nominal current range 0.2 A ... 3.6 A Switching rate Max. 30 per minute (observe derating) Motor monitoring Parameterization range 0.2 A ... 3.6 A (steps of 50/100/200 mA, via fieldbus) Overspeed tripping ≥ 20 A (after 0.3 seconds) Inline potentials Communications power UL 7.5 V Current consumption from UL max. 45 mA Segment supply voltage US 24 V DC (nominal value) Current consumption from US max. 50 mA General Weight 450 g Note on weight specifications Without plug Mounting type DIN rail Protection class I, IEC 61140, EN 61140, VDE 0140-1 Note Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector Test section Supply voltage UL/400 V level 1.2 kV AC 50 Hz 1 min Supply voltage US/400 V level 1.2 kV AC 50 Hz 1 min Supply voltage US/brake control switch 1.2 kV AC 50 Hz 1 min Supply voltage UL/brake control switch 1.2 kV AC 50 Hz 1 min Remote bus/400 V level 1.2 kV AC 50 Hz 1 min Remote bus/Brake control switch 1.2 kV AC 50 Hz 1 min Conformance with EMC directives Noise immunity test in accordance with EN 61000-6-2 Discharge of electrostatic electricity (ESD) EN 61000-4-2:1995/IEC 61000-4-2 6 kV contact discharge, criterion B; 8 kV air discharge, criterion B Electromagnetic fields EN 61000-4-3:1993/IEC 61000-4-3 Criterion A; field strength: 3 V/m Fast transients (Burst) EN 61000-4-4:1995/IEC 61000-4-4 Criterion B; Supply lines: 2 kV; Signal/data lines: 2 kV 09/08/2014   Page 3 / 6 https://www.phoenixcontact.com/us/products/2727352 Inline terminal - IB IL 400 ELR 1-3A - 2727352 Technical data General Transient surge voltage (Surge) EN 61000-4-5:1995/IEC 61000-4-5 Criterion B; supply lines DC: 0.5 kV/0.5 kV (symm./asymm.); criterion B; supply lines AC: 2 kV/4 kV (symm./asymm.) Conducted interference EN 61000-4-6:1993/IEC 61000-4-6 Criterion A; Test voltage 10 V Noise emission Noise emission test of the housing EN 55011:1991 class A in accordance with EN 61000-6-4 Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 2g, evaluation criterion 1 Shock in acc. with EN 60068-2-27/IEC 60068-2-27 10g, evaluation criterion 1 Diagnostics messages Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module Classifications eCl@ss eCl@ss 4.0 27250309 eCl@ss 4.1 27250309 eCl@ss 5.0 27250304 eCl@ss 5.1 27242609 eCl@ss 6.0 27242609 eCl@ss 7.0 27242609 eCl@ss 8.0 27242609 ETIM ETIM 2.0 EC001433 ETIM 3.0 EC001601 ETIM 4.0 EC001601 ETIM 5.0 EC001605 UNSPSC UNSPSC 6.01 43172015 UNSPSC 7.0901 43201404 UNSPSC 11 43172015 UNSPSC 12.01 43201404 UNSPSC 13.2 43201404 09/08/2014   Page 4 / 6 https://www.phoenixcontact.com/us/products/2727352 Inline terminal - IB IL 400 ELR 1-3A - 2727352 Approvals Approvals Approvals GOST Ex Approvals Approvals submitted Approval details GOST  Drawings Connection diagram Dimensioned drawing D E 1 M 224 L1 L2 L3 L1 N L2 PE L3 N 109 PE T1 T2 T3 PE 09/08/2014   Page 5 / 6 https://www.phoenixcontact.com/us/products/2727352 Inline terminal - IB IL 400 ELR 1-3A - 2727352 Block diagram Phoenix Contact 2014 © - all rights reserved http://www.phoenixcontact.com 09/08/2014   Page 6 / 6
2727352 价格&库存

很抱歉,暂时无法提供与“2727352”相匹配的价格&库存,您可以联系我们找货

免费人工找货