Inline terminal - IB IL 400 MLR 1-8A - 2727365
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Inline power-level terminal blocks, electronic direct starter, up to 3.7 kW / 400 V AC
Product description
INTERBUS Inline power-level terminals enable standard three-phase motors to be switched, protected, and monitored via INTERBUS.
The terminals in the product range are available as direct and reversing starters in electronic and electromechanical versions.
Each power-level terminal is equipped with electronic motor protection and provides the same advantages as the INTERBUS motor starter,
such as motor current monitoring, overcurrent protection, and quick shutdown according to IEC. The integrated controller supports motor current
parameterization via INTERBUS in the performance ranges from 15 W to 1.5 kW and 0.1 kW to 3.7 kW.
As with all Inline automation terminals, the power-level terminals can be snapped on and mounted on a DIN rail without tools.
Labeling is carried out directly on the module using the familiar zack marker strip and a snap-on label with large-surface labeling option.
Additional features include:
- Mains voltage up to 400 V AC 3~
- Mains output power: electronic: 15 W to 1.5 kW, electromechanical version: 0.1 kW to 3.7 kW
- Manual local operation without bus supported
- Can be extended with brake function as an option
- Thermal motor monitoring using Inline thermistor terminal
Product Features
Connection option for an external passive brake module
Hand-held operator panel mode
Integrated electronic motor protection in accordance with IEC 60947-4
Safe isolation between mains voltage and 24 V supply voltage according to EN 50178
Diagnostic and status indicators
Motor control via OUT process data
Motor current monitoring
Key commercial data
Packing unit
1 pc
Weight per Piece (excluding packing)
680.0 GRM
Custom tariff number
85389091
Country of origin
Germany
Technical data
Note
09/08/2014 Page 1 / 7
https://www.phoenixcontact.com/us/products/2727365
Inline terminal - IB IL 400 MLR 1-8A - 2727365
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
63 mm
Height
224 mm
Depth
109 mm
Ambient conditions
Ambient temperature (operation)
-25 °C ... 55 °C
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
75 % ... 85 % (75% average, 85% seldom)
Permissible humidity (storage/transport)
75 % ... 85 % (75% average, 85% seldom)
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Degree of protection
IP20
Interfaces
Fieldbus system
Lokalbus
Designation
Inline local bus
Connection method
Inline data jumper
Transmission speed
500 kBit/s
Transmission physics
Copper
Power supply for module electronics
Connection method
Through the potential jumper
Designation
Terminal strips X11 and X12
Mains connection
Designation
Mains connection
Connection method
Power connector or power bridge
Designation connection point
Terminal strip; X11 and X12
Number of positions
5
Permissible conductor cross section
max. 2.5 mm² (L1+L2+L3+N-PE)
Operating voltage
187 V AC ... 500 V AC +0 % (conductor voltage)
Max. current carrying capacity
20 A
Motor starter, output
Connection method
(3-phase), via COMBICON
Number
1
09/08/2014 Page 2 / 7
https://www.phoenixcontact.com/us/products/2727365
Inline terminal - IB IL 400 MLR 1-8A - 2727365
Technical data
Motor starter, output
Output name
Motor outputs (three phases), short-circuit-proof with external line
protection fuse 20 A
Designation connection point
Terminal strip; X10
Number of positions
4
Permissible conductor cross section
1 mm² ... 2.5 mm²
Operating voltage
200 V AC ... 600 V AC +0 %
Frequency range
50 Hz ... 60 Hz
Nominal current range
0.2 A ... 8 A
Switching rate
Max. 5 cycles per minute
Motor monitoring
Parameterization range
0.2 A ... 8 A (steps of 50/100/200 mA, via fieldbus)
Overspeed tripping
≥ 40 A (after 0.3 seconds)
Thermistor input
Number of inputs
2
Inline potentials
Communications power UL
7.5 V
Current consumption from UL
max. 45 mA
Segment supply voltage US
24 V DC (nominal value)
Current consumption from US
max. 160 mA
General
Weight
550 g
Note on weight specifications
Without plug
Mounting type
DIN rail
Protection class
I, IEC 61140, EN 61140, VDE 0140-1
Note
Notes on operation Line protection for the network supply line, max. 20 A.
Observe derating of the POWER-COMBICON connector
Test section
Supply voltage UL/400 V level 1.2 kV AC 50 Hz 1 min
Supply voltage US/400 V level 1.2 kV AC 50 Hz 1 min
Supply voltage US/brake control switch 1.2 kV AC 50 Hz 1 min
Supply voltage UL/brake control switch 1.2 kV AC 50 Hz 1 min
Remote bus/400 V level 1.2 kV AC 50 Hz 1 min
Remote bus/Brake control switch 1.2 kV AC 50 Hz 1 min
Conformance with EMC directives
Test for immunity to interference in acc. with EN 50082-2:1995 Discharge
of electrostatic electricity (ESD) EN 61000-4-2:1995/IEC 61000-4-2 6 kV
contact discharge, criterion B; 8 kV air discharge, criterion B
Electromagnetic fields EN 61000-4-3:1993/IEC 61000-4-3 Criterion A; field
strength: 3 V/m
09/08/2014 Page 3 / 7
https://www.phoenixcontact.com/us/products/2727365
Inline terminal - IB IL 400 MLR 1-8A - 2727365
Technical data
General
Fast transients (Burst) EN 61000-4-4:1995/IEC 61000-4-4 Criterion B;
Supply lines: 2 kV; Signal/data lines: 2 kV
Transient surge voltage (Surge) EN 61000-4-5:1995/IEC 61000-4-5
Criterion B; supply lines DC: 0.5 kV/0.5 kV (symm./asymm.); criterion B;
supply lines AC: 2 kV/4 kV (symm./asymm.)
Conducted interference EN 61000-4-6:1993/IEC 61000-4-6 Criterion A;
Test voltage 10 V
Noise emission
Test of emitted interference, housing, in acc. with EN 50081-2:1993 EN
55011:1991 class A
Mechanical tests
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 1g,
evaluation criterion 1
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 10g, evaluation
criterion 1
Diagnostics messages
Overcurrent Error message in the diagnostic code (bus) and display via the
LED ERR on the module
Output stage cannot be controlled Error message in the diagnostic code
(bus) and display via the LED ERR on the module
Module error during self test Message to the master
Classifications
eCl@ss
eCl@ss 4.0
27250309
eCl@ss 4.1
27250309
eCl@ss 5.0
27250304
eCl@ss 5.1
27242609
eCl@ss 6.0
27242609
eCl@ss 7.0
27242609
eCl@ss 8.0
27242609
ETIM
ETIM 2.0
EC001433
ETIM 3.0
EC001601
ETIM 4.0
EC001601
ETIM 5.0
EC001605
UNSPSC
UNSPSC 6.01
43172015
UNSPSC 7.0901
43201404
UNSPSC 11
43172015
UNSPSC 12.01
43201404
09/08/2014 Page 4 / 7
https://www.phoenixcontact.com/us/products/2727365
Inline terminal - IB IL 400 MLR 1-8A - 2727365
Classifications
UNSPSC
UNSPSC 13.2
43201404
Approvals
Approvals
Approvals
UL Listed / GOST / cUL Listed / cULus Listed
Ex Approvals
Approvals submitted
Approval details
UL Listed
GOST
cUL Listed
cULus Listed
Drawings
09/08/2014 Page 5 / 7
https://www.phoenixcontact.com/us/products/2727365
Inline terminal - IB IL 400 MLR 1-8A - 2727365
Connection diagram
Dimensioned drawing
D
E
1
M
224
L1
L2
L3
L1
N
L2
PE
L3
N
109
PE
T1 T2 T3 PE
09/08/2014 Page 6 / 7
https://www.phoenixcontact.com/us/products/2727365
Inline terminal - IB IL 400 MLR 1-8A - 2727365
Block diagram
Phoenix Contact 2014 © - all rights reserved
http://www.phoenixcontact.com
09/08/2014 Page 7 / 7