Bus coupler with remote bus branch for INTERBUS; twisted pair with 500 kbaud, rugged metal housing with IP67
protection, tool-free mounting on a separate mounting plate, can be used directly on welding robots
The illustration shows version IBS
RL 24 BK RB-LK-LK
Product description
INTERBUS Ruggedline modules are provided for harsh ambient conditions or in the case of high requirements regarding system diagnostics. To ensure
maximum availability, these modules are equipped with a zinc die-cast housing (IP67). Therefore, they can be installed in the direct vicinity of welding
tongs.
Each Ruggedline module consists of a mounting plate and and electronics module. The electronics module is snapped onto the mounting plate and
fixed with two screws if necessary.
I/O errors can be clearly localized by means of extended diagnostics. Short-circuits of the power supply of the sensors, for example, are reported in
groups of 4 inputs. And, in the case of a short-circuit at an output, the respective output is even reported directly. This information will be made available
to the controller and displayed at the module.
In the case of modules with fiber optic connection, the diagnostics capability even goes one step further. By using the latest fiber optic technology, the
quality of the transmission path is permanently ascertained and optimally adjusted. This information is available to the controller and at the module.
Due to these additional features, slow deterioration of the transmission path can be detected before errors occur during transmission or transmission is
interrupted.
In the case of Ruggedline modules, the bus medium can be selected. Apart from versions with fiber optic connection (polymer fiber), there are modules
which are used with twisted pair cables. The bus medium can be changed from FO installation to a copper medium at any time using the corresponding
plug-in adapters.
The bus is connected by means of IP67 plug-in plugs, which transport both the bus signal and the power supply to the modules. For easy preparation,
the power supply cable is connected to the plug using the QUICKON fast connection method, and connection of the fiber optic cable is made using a
simple cutting and assembly tool; additional polishing is not necessary.
If a fiber optic bus cable is assembled by the user, e.g. the bridge between 2 modules, it must be at least one meter long. For shorter cable bridges,
please use only cable bridges from Phoenix Contact.
Product Features
Rugged metal housing
Comprehensive diagnostic functions
M12 connector for I/O devices
Rugged Line connector for INTERBUS, either with fiber optic or twisted pair, and supply voltage
Key commercial data
Packing unit
1 pc
09/08/2014 Page 1 / 4
https://www.phoenixcontact.com/us/products/2731063
Bus coupler - IBS RL 24 BK RB-T-T - 2731063
Weight per Piece (excluding packing)
798.6 GRM
Custom tariff number
85389091
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
179 mm
Height
67 mm
Depth
71 mm
Note on dimensions
With bus connectors and mounting plate
Ambient conditions
Ambient temperature (operation)
0 °C ... 55 °C
Ambient temperature (storage/transport)
-25 °C ... 70 °C
Permissible humidity (operation)
100 %
Permissible humidity (storage/transport)
95 % (non-condensing)
Air pressure (operation)
860 hPa ... 1080 hPa (up to 1500 m above mean sea level)
Air pressure (storage/transport)
660 hPa ... 1080 hPa (up to 3500 m above mean sea level)
Degree of protection
IP65/IP67
General
Weight
610 g
Mounting type
Wall mounting
Protection class
III, IEC 61140, EN 61140, VDE 0140-1
Air and creepage distances
According to EN 50178: 1998
Interfaces
Fieldbus system
INTERBUS
Designation
INTERBUS
Connection method
Copper via IP67 RL connectors
Transmission speed
500 kBit/s
Power supply for module electronics
Supply voltage
24 V DC
Supply voltage range
18.5 V DC ... 32 V DC (including ripple)
Ripple
Max 3.6 VSS within the permissible voltage range
Current consumption
typ. 120 mA
09/08/2014 Page 2 / 4
https://www.phoenixcontact.com/us/products/2731063
Bus coupler - IBS RL 24 BK RB-T-T - 2731063
Classifications
eCl@ss
eCl@ss 4.0
27250203
eCl@ss 4.1
27250203
eCl@ss 5.0
27250203
eCl@ss 5.1
27242608
eCl@ss 6.0
27242608
eCl@ss 7.0
27242608
eCl@ss 8.0
27242608
ETIM
ETIM 2.0
EC001434
ETIM 3.0
EC001604
ETIM 4.0
EC001604
ETIM 5.0
EC001604
UNSPSC
UNSPSC 6.01
43172015
UNSPSC 7.0901
43201404
UNSPSC 11
43172015
UNSPSC 12.01
43201404
UNSPSC 13.2
43201404
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / INTERBUS CLUB / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
09/08/2014 Page 3 / 4
https://www.phoenixcontact.com/us/products/2731063
Bus coupler - IBS RL 24 BK RB-T-T - 2731063
Approvals
UL Recognized
Nominal current IN
0.12 A
Nominal voltage UN
24 V
cUL Recognized
Nominal current IN
0.12 A
Nominal voltage UN
24 V
INTERBUS CLUB
cULus Recognized
Drawings
Connection diagram
IB DIAGRC RD 1RD 2 E LWL 1 LWL 2 LWL 3US 1US 2
INTERBUS
IN
INTERBUS
OUT
REMOTE
BUS BRANCH
Phoenix Contact 2014 © - all rights reserved
http://www.phoenixcontact.com