0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2731102

2731102

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    TERMINATION BOARD

  • 数据手册
  • 价格&库存
2731102 数据手册
Extract from the online catalog     IBS S7 400 ETH DSC/I-T Order No.: 2731102 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2731102     Termination board, with electrical isolation Product notes WEEE/RoHS-compliant since: 10/28/2008 Commercial data GTIN (EAN) 4 017918 185756 sales group K010 Pack 1 pcs. Customs tariff 85371091 Catalog page information Page 119 (AX-2009) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Product description INTERBUS controller board for Siemens SIMATIC S7-400 PLCs The IBS S7 400 DSC/I-T INTERBUS controller board permits the INTERBUS to be connected to the SIMATIC S7 400. The distinguishing features of the controller board are the ease of operation and the numerous processing functions, such as: Data preprocessing, synchronous operating modes, extended parameterization via CMD, and PCP communication. The diagnostics display shows operational and error states in plain text, thus reducing startup times to a minimum. PHOENIX CONTACT Deutschland GmbH http://www.phoenixcontact.de Page 1 / 5 Feb 8, 2011 IBS S7 400 ETH DSC/I-T Order No.: 2731102 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2731102 Configuration and programming are carried out in the Step 7 environment. In addition, the IBS S7 400 ETH DSC/I-T controller board permits several controller boards to be connected, controlled and configured with IBS CMD via a higher level Ethernet network. For this purpose, you can choose between the AUI and the 10Base-T interface. Technical data Control system Control system SIMATIC® S7-400 controllers Programming tool STEP 7 from version 5.x Diagnostics tool DIAG+ from version 1.0x Configuration tool CMD from version 4.5x Software interfaces Application interface S7 I/O driver S7 function blocks Software requirements Configuration tool CMD from version 4.5x Config+ from version 1.00 onwards Diagnostics tool DIAG+ from version 1.0x Programming tool STEP 7 from version 5.x Power supply Power supply connection Via SIMATIC I/O bus Typical current consumption 2.5 A Supply voltage 5 V DC General data Weight 1200 g Format 2 slots Width 50 mm Height 290 mm Depth 210 mm Degree of protection IP20 Ambient temperature (operation) 0 °C ... 60 °C Ambient temperature (storage/transport) -25 °C ... 65 °C Permissible humidity (operation) 30 % (up to 75%, without condensation) Permissible humidity (storage/transport) 30 % (up to 95%, without condensation) PHOENIX CONTACT Deutschland GmbH http://www.phoenixcontact.de Page 2 / 5 Feb 8, 2011 IBS S7 400 ETH DSC/I-T Order No.: 2731102 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2731102 Air pressure (operation) 860 hPa ... 1080 kPa (up to 1500 m above mean sea level) Air pressure (storage/transport) 660 hPa ... 1080 kPa (up to 3500 m above mean sea level) Data interfaces Interface Control system Type of connection SIMATIC S7-400 P bus Interface INTERBUS remote bus Type of connection 9-pos. D-SUB socket strip Transmission speed 500 kBit/s / 2 MBit/s Interface Parameterization/operation/diagnostics Type of connection RS-232-C, D-SUB male connector Interface Ethernet Type of connection 10/100Base-T via RJ45 Interrupts Are supported ® INTERBUS data Type INTERBUS master Number of devices with parameter channel (PCP) max. 126 (512 words) Number of supported devices max. 512 (of which 254 are remote bus devices/bus segments) Number of I/O nodes max. 8192 Certificates / Approvals Certification CUL, GOST, UL Accessories Item Designation Description Cable/conductor 2806862 IBS PRG CAB Connection cable, to connect the controller boards to the PC (RS-232-C), length 3 m IBS MC FLASH 2MB Program and configuration memory, 2 Mbyte Memory 2729389 PHOENIX CONTACT Deutschland GmbH http://www.phoenixcontact.de Page 3 / 5 Feb 8, 2011 IBS S7 400 ETH DSC/I-T Order No.: 2731102 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2731102 Software 2730307 DIAG+ Diag+, diagnostics software, for INTERBUS networks, area of application: Startup, maintenance and, for example, for integration in control desk software, can be integrated in 32 bit applications (ActiveX-capable) FAQs • Can I store the IP address of my controller board permanently on the parameterization memory (IBS MC FLASH ...)? The IP address can be stored on the parameterization memory with device firmware 4.6x or later on the following memory cards (with the layout described below): 27 29 38 9 IBS MC FLASH 2 MB 27 29 39 2 IBS MC FLASH 4 MB 27 12 52 9 IBS MC FLASH 16 MB 27 12 53 2 IBS MC FLASH 32 MB 27 12 54 5 IBS MC FLASH 64 MB The IP address cannot be stored on the IBS MC FLASH (1 MB) parameterization memory available. When the controller board is used in conjunction with an IBS MC FLASH (1 MB) memory card, the IP address is stored internally in the device. • Function block FC12 MAUWARN FC 12 MAUWARN is responsible for detecting incoming event messages of type 5340 with the codes BB5 and BB6 (decline in the transmission quality with optically regulated FO transmission paths in Interbus) and to output the relevant device number. Please note that during startup of the bus system in CMD, a set indication service must be added before enabling the exclusive rights service. The service has the following parameters: (all values are hex values) Service: Set Indication 152 length 3 Indication_Ability 1 Distribution 2 Indication_Code 5340 Attention: No user function or event definition may be generated in CMD as a result of this event as the service would otherwise not be transmitted to the controller. • Setting the number of internal FC loops for FC 28 (IB_SYNC) Unlike the header for the S7 block (< Version 1.5), the maximum number of internal FC loops is not described in DBW 190 in the IBDB, but is stored in DBW 188. PHOENIX CONTACT Deutschland GmbH http://www.phoenixcontact.de Page 4 / 5 Feb 8, 2011 IBS S7 400 ETH DSC/I-T Order No.: 2731102 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2731102 Address PHOENIX CONTACT Deutschland GmbH Flachsmarktstr. 8 32825 Blomberg,Germany Phone +49 5235 3 12000 Fax +49 5235 3 41200 http://www.phoenixcontact.de © 2011 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Deutschland GmbH http://www.phoenixcontact.de Page 5 / 5 Feb 8, 2011
2731102 价格&库存

很抱歉,暂时无法提供与“2731102”相匹配的价格&库存,您可以联系我们找货

免费人工找货