0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2736699

2736699

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    Enclosed AC DC Converter 1 Output 30.1V 6A 85 ~ 264 VAC Input

  • 数据手册
  • 价格&库存
2736699 数据手册
Extract from the online catalog     ASI QUINT 100-240/4.8 EFD Order No.: 2736699 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2736699   Power supply unit für AS interface, 4.8 A, integrated ground fault detector, IP20 degree of protection   Product notes WEEE/RoHS-compliant since: 11/15/2006 Commercial data GTIN (EAN) 4 017918 959685 sales group L175 Pack 1 pcs. Customs tariff 85044082 Catalog page information Page 396 (AX-2009) http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Product description Power supply unit for AS-Interface systems. Special power supply units with an output voltage range of 29.5 V - 31.6 V DC are used to supply the AS-Interface systems. The AS-i system also requires a data decoupling network in the power supply unit in order to be able to transmit communication signals along the power line. The ASI QUINT 100-240/2.4 EFD power supply unit can supply an AS-i system with up to 2.4 A. Safety through automatic ground fault detection If two ground faults occur in an AS-i system, this can cause the machines to inadvertently start up or not to be able to stop operation. The power supply unit has an integrated ground fault detection function. A ground fault is signaled via LED and a signal output. Worldwide use The wide-range input of PHOENIX CONTACT Deutschland GmbH http://www.phoenixcontact.de Page 1 / 5 Jan 24, 2011 ASI QUINT 100-240/4.8 EFD Order No.: 2736699 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2736699 the power supply unit can be operated with all conventional AC and DC networks without having to make any settings. The devices can thus be used worldwide. Technical data Input data Nominal input voltage 100 V AC ... 240 V AC AC input voltage range 85 V AC ... 264 V AC DC input voltage range 90 V DC ... 350 V DC AC frequency range 45 Hz ... 65 Hz DC frequency range 0 Hz Current consumption Approx. 1.8 A (120 V AC) 1 A (230 V AC) Nominal power consumption 144 W Inrush surge current < 15 A (typical) Power failure bypass > 60 ms (120 V AC) > 100 ms (230 V AC) Input fuse 5 A (slow-blow, internal) Permissible backup fuse B6 B10 B16 Output data Nominal output voltage 30.1 V DC ± 1.5% Output current 4.8 A (Up to +60°C) 6A Connection in parallel No Connection in series Yes Residual ripple < 30 mVPP Peak switching voltages nominal load < 50 mVPP Maximum power dissipation idling 4W Power loss nominal load max. 16 W General data Width 70 mm Height 145 mm Depth 125 mm Width with alternative assembly 122 mm PHOENIX CONTACT Deutschland GmbH http://www.phoenixcontact.de Page 2 / 5 Jan 24, 2011 ASI QUINT 100-240/4.8 EFD Order No.: 2736699 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2736699 Height with alternative assembly 145 mm 73 mm Net weight 0.9 kg Operating voltage display LED Efficiency > 89 % (At 230 V AC and nominal values) Insulation voltage input/output 4 kV AC (type test) 2 kV AC (routine test) Degree of protection IP20 Protection class I, IEC 61140, EN 61140, VDE 0140-1 MTBF (IEC 61709, SN 29500) > 500000 h Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C derating) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) 95 % (at 25°C, no condensation) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Can be aligned: Horizontal 0 cm, vertical 5 cm Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Low Voltage Directive Conformance with LV directive 2006/95/EC Standard - Safety of transformers EN 61558-2-17 Standard - Electrical safety EN 60950/VDE 0805 (SELV) DIN VDE 0100-410 Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard - Safe isolation DIN VDE 0100-410 DIN VDE 0106-1010 Standard – Limitation of mains harmonic currents EN 61000-3-2 UL approvals UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950 Connection data, input Type of connection Pluggable spring-cage connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 PHOENIX CONTACT Deutschland GmbH http://www.phoenixcontact.de Page 3 / 5 Jan 24, 2011 ASI QUINT 100-240/4.8 EFD Order No.: 2736699 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2736699 Stripping length 10 mm Screw thread M3 Connection data, output Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Certificates / Approvals Certification CB, CUL, CUL Listed, GOST, UL, UL Listed Diagrams/Drawings Block diagram PHOENIX CONTACT Deutschland GmbH http://www.phoenixcontact.de Page 4 / 5 Jan 24, 2011 ASI QUINT 100-240/4.8 EFD Order No.: 2736699 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2736699 Address PHOENIX CONTACT Deutschland GmbH Flachsmarktstr. 8 32825 Blomberg,Germany Phone +49 5235 3 12000 Fax +49 5235 3 41200 http://www.phoenixcontact.de © 2010 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Deutschland GmbH http://www.phoenixcontact.de Page 5 / 5 Jan 24, 2011
2736699 价格&库存

很抱歉,暂时无法提供与“2736699”相匹配的价格&库存,您可以联系我们找货

免费人工找货