2753232

2753232

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
2753232 数据手册
IBS ST (ZF) 24 BK LB-T Bus Terminal Module With Local Bus Branch Data Sheet 5049B 4 6 1 5 Terminal Assignment 1 6 7 8 T E R B IB S S T 2 4 B K L B -T U S U L R C B A 1 B A 2 E 1 E 2 L D 1 R D in ec om po 1 2 R e c o n fig u r a tio n L D 2 ne nt IN Terminals Assignment 1 Supply voltage of the module 4 Supply voltage of the reconfiguration input 2 (optional) 6 Supply voltage of the alarm contact (optional) 8 Supply voltage of the reconfiguration input 1 (optional) 9 Ground contact of the module 12 Ground contact of the reconfiguration input 2 14 Ground contact of the alarm contact 16 Ground contact of the reconfiguration input 1 s. F U S E 1 1 4 m 1 2 5049B000 co 9 09/1999 B u s T e r m in a l, 2 4 V D C M o d u le Id e n t. 1 : 0 8 , M o d u le Id e n t. 2 : 5 2 R e m o te b u s O U T on l R e m o te b u s IN Des. UL L o c a l b u s b ra n c h 5 0 4 9 B 0 0 1 Figure 1 IBS ST 24 BK LB-T module This data sheet is intended to be used in conjunction with the IBS SYS PRO UM E Manual. Ground the mounting rail. The module is grounded by snapping it onto the mounting rail. 5049B Local Diagnostic and Status Indicators Color Meaning Green Supply voltage for the electronics module RC Green Remote bus cable check BA1/2 Green Remote bus active E1 Red Error in the ST compact station (local bus group) E2 Red Error in the local bus branch LD1 Red ST compact station (local bus group) disconnected LD2 Red Local bus branch disconnected RD Red Remote bus disconnected 1 IBS ST (ZF) 24 BK LB-T Connection Example Connection of the Supply Voltages and the Bus Cables U L + U _ U R E C 2 _ + A + U _ R E C 1 + _ T o b e w ir e d e x te r n a lly 1 3 1 4 1 5 1 6 4 5 6 7 8 F U S E 1 1 2 B A 1 B A 2 nt E 1 E 2 L D 1 L D 2 R D om 1 2 R e c o n fig u r a tio n in ec F a s te n e le c tr o n ic s m o d u le w ith s c r e w o n te r m in a l b lo c k b a s e . R C IB S S T 2 4 B K L B -T U S po U L B T E R ne IN s. 9 co m In te r n a lly c o n n e c te d B u s T e r m in a l, 2 4 V D C M o d u le Id e n t. 1 : 0 8 , M o d u le Id e n t. 2 : 5 2 L o c a l b u s b ra n c h on l R e m o te b u s IN R e m o te b u s O U T 5 0 4 9 B 0 0 2 Figure 2 Connection of the supply voltage and bus cables UREC1/2: Voltage supply of the reconfiguration inputs (optional). These inputs can only be used together with group definitions. As the terminals 9, 12, and 16 are connected with each other, the reconfiguration inputs and the power supply are assigned to the same potential. 2 UL: Power supply for the bus logic UA: Voltage supply for the alarm input (optional). 5049B IBS ST (ZF) 24 BK LB-T Functioning of the Alarm Contact A la r m A la r m n o t s e t a n d IN T E R B U S c o n n e c te d s e t 1 4 1 4 1 5 1 5 6 5 0 4 9 B 0 0 3 m 6 co Figure 3 Functioning of the alarm contact Programming Data Assignment of the Reconfiguration Inputs 0hex 0 bytes Output address area 0 bytes Parameter channel (PCP) 0 bytes Register length (bus) 0 bytes Disconnection of the ST compact station om Programmable functions po Input address area Yes Disconnection of the outgoing remote bus Yes Reset of the outgoing remote bus Yes Monitoring of the incoming remote bus cable Yes Disconnection of local bus Yes in ec R E C 1 R E C 2 ID : 0 8 (d e c ) ID : 5 2 (d e c ) S T c o m p a c t s ta tio n L o c a l b u s b ra n c h Yes Reset of the ST compact station on l IB S S T 2 4 B K L B -T ne Length code B u s te r m in a l m o d u le nt 8hex, 8dec 34hex ,52dec s. R e m o te b u s IN ID code ST compact station Local bus branch R e m o te b u s O U T 5 0 4 9 B 0 0 4 Figure 4 Assignment of the reconfiguration inputs The bus terminal module and the local bus branch are programmed like two individual bus terminal modules. Therefore, both ID codes must be entered in the address lists. 5049B 3 IBS ST (ZF) 24 BK LB-T Technical Data General 81 mm x 117 mm x 116 mm (3.189 in. x 4.606 in. x 4.567 in.) Permissible operating temperature From 0°C to 55°C (32°F to 131°F) Permissible storage temperature From -20°C to 70°C (-4°F to +158°F) Degree of protection IP 20, DIN 40050, IEC 60529 Class of protection Class 3 VDE 0106, IEC 60536 Humidity (operation) 30% to 75%, no condensation Humidity (storage) 30% to 95%, no condensation Air pressure (operation) From 86 to 108 kPa, 1500 m (4921 ft.) above sea level Air pressure (storage) From 66 to 108 kPa, 3500 m (11483 ft.) above sea level ne nt s. co m Housing dimensions (width x height x depth) Test voltage Incoming/outgoing remote bus Incoming remote bus/local bus branch Supply voltage/ST local bus Protective ground Weight Interfaces on l INTERBUS in ec Preferred installation position om Incoming remote bus/ST local bus 500 V AC, 1 min., 50 Hz po Electrical isolation 500 V AC, 1 min., 50 Hz 500 V AC, 1 min., 50 Hz 500 V AC, 1 min., 50 Hz Panel mounting Via DIN rail 470 g, typical Incoming remote bus 9-pos. D-SUB male connector Outgoing remote bus 9-pos. D-SUB female connector ST interface ST cable (supplied with the module) Local bus 15-pos. D-SUB female connector (supply voltage is not carried in the local bus branch) Number of ST modules that can be connected 8 (note the current load) Maximum distance to the next remote bus device 400 m (1312 ft.) Maximum distance to the next local bus device 1.5 m (3.280 ft.) 4 5049B IBS ST (ZF) 24 BK LB-T Interfaces Alarm contact Terminal points 6, 14, and 15 (see Figure 3) Maximum voltage 30 V DC/AC Maximum current 0.5 A Reconfiguration inputs Pushbutton 1 (manual operation) Local bus branch Pushbutton 2 (manual operation) Terminal points of the ST compact station 8 (+) and 16 (-) Terminal points of local bus branch 4 (+) and 12 (-) Nominal voltage UREC1/2 24 V DC Permissible voltage range -30 V to 30 V (DC) nt s. co m ST compact station ne Set: 13 V to 30 V (DC) Not set: -30 V to 1 V Power Consumption Current consumption of US om Communications power I/O supply voltage Us 2 mA, typical po Current consumption (set) 9 V DC 24 V DC 150 mA at 24 V, typical Maximum 650 mA at 24 V, typical in ec Without ST local bus modules on l Total current consumption of all I/O modules on 800 mA at 9 V, maximum the ST local bus I/O Supply Voltage (US) Nominal value 24 V DC Permissible ripple 3.6 Vpp within the permissible voltage range Permissible voltage range (including ripple) Operation: 20 V DC to 30 V DC 5049B 5 IBS ST (ZF) 24 BK LB-T I/O Supply Voltage (US) Current consumption of US Without ST I/O modules 150 mA at 24 V, typical Maximum 650 mA at 24 V, typical Permissible total current consumption of all I/O 800 mA at 9 V, maximum modules Fuses in the base element IBS TR5 1 AT co m Surge voltage protection s. Ordering Data Order Designation Order No. BK module (screw-clamp terminals) IBS ST 24 BK LB-T 27 53 23 2 BK module (spring-clamp terminals) IBS ST ZF 24 BK LB-T 27 50 77 2 Electronics module IB STME 24 BK LB-T 27 53 24 5 Replacement terminal block (screw-clamp terminals) IB STTB 24 BK LB-T 27 52 69 9 Replacement terminal block (spring-clamp terminals) IB STTB ZF 24 BK LB-T 27 50 88 2 on l in ec om po ne nt Description 6 5049B on l in ec om po ne nt s. co m IBS ST (ZF) 24 BK LB-T 5049B 7 8 © Phoenix Contact 09/1999 TNR 92 65 66 8 s. nt ne po om in ec on l co m IBS ST (ZF) 24 BK LB-T 5049B
2753232 价格&库存

很抱歉,暂时无法提供与“2753232”相匹配的价格&库存,您可以联系我们找货

免费人工找货